Troubleshooting<br />

11 Troubleshooting<br />

Compressor does not run<br />

Fault Possible cause Remedy<br />

U KL = 0 V<br />

There is an interruption in the connection<br />

between the battery and the<br />

electronics<br />

Establish a connection<br />

Main switch faulty (if installed) Replace the main switch<br />

Additional supply line fuse has blown<br />

(if installed)<br />

Replace the supply line<br />

fuse<br />

U KL ≤ U ON Battery voltage is too low Charge the battery<br />

Start attempt with<br />

U KL ≤ U OFF<br />

Loose cables<br />

Poor contact (corrosion)<br />

Establish a connection<br />

Battery capacity too low<br />

Cable cross section too small<br />

Start attempt with Ambient temperature too high –<br />

U KL ≥ U ON<br />

Electric circuit between<br />

the pins in the compressor<br />

interrupted<br />

Usage when the ambient<br />

temperature is too<br />

low<br />

Insufficient ventilation and/or air<br />

supply<br />

Condenser is dirty<br />

Fan defective (if installed)<br />

Defective compressor<br />

The compressor only starts up at an<br />

ambient temperature of more than<br />

+16 °C.<br />

Replacing the battery<br />

Replace the cable<br />

(fig. 8, page 6)<br />

Move the freezer to<br />

another location<br />

Clean the condenser<br />

Replace the fan<br />

Replace the compressor<br />

Only switch on the freezer<br />

at an ambient temperature<br />

of more than +16 °C.<br />

U KL<br />

U ON<br />

U OFF<br />

Voltage between the positive and negative terminals of the electronics<br />

Cut-in voltage of the electronics<br />

Cut-off voltage of the electronics<br />

Interior temperature too low in control level “1”<br />

Fault Possible cause Remedy<br />

Compressor runs constantly<br />

Compressor runs for a<br />

long time<br />

Thermostat sensor has no contact on<br />

the vaporiser<br />

Faulty thermostat<br />

Large quantities have been frozen in<br />

the freezer compartment<br />

Secure the sensor<br />

Change the thermostat<br />