CoolMatic CRF-50 - Waeco
CoolMatic CRF-50 - Waeco
CoolMatic CRF-50 - Waeco
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Technical data<br />
<strong>CoolMatic</strong> <strong>CRF</strong>-<strong>50</strong><br />
Poor cooling, interior temperature increases<br />
Fault Possible cause Remedy<br />
Compressor runs for a<br />
long time/continuously<br />
Compressor runs<br />
intermittently<br />
Vaporiser is iced over<br />
Defrost the vaporiser<br />
Ambient temperature too high –<br />
Insufficient ventilation and/or air supply<br />
Condenser is dirty<br />
Fan defective (if installed)<br />
Battery capacity exhausted<br />
Move the freezer to<br />
another location<br />
Clean the condenser<br />
Replace the fan<br />
Charge the battery<br />
Unusual noises<br />
Fault Possible cause Remedy<br />
Loud humming<br />
A component of the refrigerant circuit<br />
cannot move freely (touching the wall)<br />
Bend the component<br />
carefully away from the<br />
obstruction<br />
Foreign body jammed between the Remove the foreign body<br />
cooling unit and the wall<br />
Fan noise (if installed) –<br />
12 Technical data<br />
Item number:<br />
<strong>CRF</strong>-00<strong>50</strong>E<br />
Voltage:<br />
12 V DC or 24 V DC<br />
Capacity:<br />
47 l<br />
Average power consumption:<br />
45 W<br />
Cooling temperature range:<br />
0 °C to max. -18° C<br />
Relative humidity: maximum 90%<br />
Constant inclination: max. 30°<br />
Dimensions (WxHxD) in mm:<br />
448x527x543<br />
Weight:<br />
25 kg<br />
Test/certificates:<br />
complies with ErP/EuP directive<br />
Versions, technical modifications and delivery options reserved.<br />
The coolant circuit contains R134a.<br />