14.1.3 Del. Bat.<br />
This function is used to erase batteries which are stored in the database but no longer required. Call<br />
up the database, select the battery to be erased using the jog dial or the arrow buttons, then confirm<br />
your selection (“OK / Menu” button) to erase the battery from the database.<br />
14.1.4 Return<br />
To return to the Conf. Menu, press “Return”, then confirm by pressing the “OK / Menu” button.<br />
14.2 C/D-Para<br />
The charge / discharge parameters are configured in the “C/D-Para”<br />
menu (Fig. 28). In this menu you can set the final discharge voltages<br />
for the various battery technologies, and also select the maximum<br />
number of charge / discharge cycles for the “Cycle” and “Form”<br />
functions. It is only possible to alter the individual parameters within<br />
the permissible limits, as this avoids a safety risk if incorrect parameters<br />
are entered.<br />
Fig. 28: Configuring charge<br />
/ discharge parameters<br />
Return? U NC? U NiMH? U Lilon? U LiPol?<br />
CyCyNiMH? CyCyNC? -dU NiMH? -dU NC? U Pb?<br />
CyFoNC? CyFoNiMH? Restore? Return?<br />
Fig. 29: Menu points in the “C/D-Para” menu<br />
Fig. 29 shows the menu points available in the “C/D-Para” menu, which are once again selected using<br />
the jog dial or the arrow buttons. Confirm your choice with the “OK / Menu” button, and you can then<br />
alter the settings within the available limits. The following parameters can be modified:<br />
U NC<br />
Final discharge voltage for NC batteries in the range 0.8 V to 1.1 V per cell<br />
U NiMH<br />
Final discharge voltage for NiMH batteries in the range 0.8 V to 1.1 V per cell<br />
U LiIon<br />
Final discharge voltage for Lithium-Ion batteries in the range 2.70 V to 3.10 V per cell<br />
U LiPol<br />
Final discharge voltage for Lithium-Polymer batteries in the range 2.70 V to 3.20 V per cell<br />
U Pb<br />
Final discharge voltage for lead-acid batteries in the range 1.70 V to 2.00 V per cell<br />
-U NC<br />
Charge cut-off detection for NC batteries, variable in the range 0.15% to 1.00% -U<br />
-U NiMH<br />
Charge cut-off detection for NiMH batteries, variable in the range 0.10% to 0.40% -U<br />
CyCy NC<br />
Maximum cycle count for NC batteries in the “Cycle” function; variable in the range 2 to 20 cycles<br />