HEAT DISSIPATION<br />

2<br />

The working temperature of the central unit enclosure must not exceed 45 ºC (113ºF). To ensure<br />

that this temperature is not exceeded, the enclosure must have enough surface to evacuate the heat<br />

generated inside and maintain the ambient conditions within the working temperature range.<br />

Calculating the surface needed to dissipate the heat<br />

The expressions have been obtained for an enclosure having a 2 mm wall and made out of aluminum.<br />

When using internal cooling, the fan is located at 30 mm from the bottom.<br />

To calculate the required total surface of the enclosure in order to dissipate the heat generated in<br />

it, the following data must be taken into account.<br />

A (m 2 ) Total surface required.<br />

P (W) Total power dissipated by all the elements that generate heat inside the<br />

enclosure, including the power supply and the fan if there is one.<br />

Ta (ºC) Ambient temperature outside the enclosure.<br />

Ti (ºC) Temperature inside the enclosure.<br />

�t (ºC) Temperature difference (Ti-Ta).<br />

Q (m 3 /h) Air flow provided by the fan, if there is one.<br />

Dissipating surface<br />

Only surfaces dissipating heat by convection will be considered, the top and the rear of the enclosure.<br />

The rest of the surfaces are not to be considered when calculating the total surface.<br />

Power dissipated by the <strong>CNC</strong><br />

The maximum power dissipated by the <strong>CNC</strong> is 55 W, power supply not included.<br />

Ta<br />

Ti<br />

Q<br />

P<br />

30mm<br />

A<br />

<strong>CNC</strong> <strong>8037</strong><br />

SOFT: V01.4X<br />

·51·