Table 1: RO Parameters<br />

Stage 1 recovery 0.75<br />

Stage 1 rejection 0.99<br />

Stage 2 recovery 0.9<br />

Stage 2 rejection 0.99<br />

Table 2: Cations and Anions in Feed Water<br />

Ion Sodium Calcium Magnesium Chloride Sulfate Carbonate<br />

Concentration (mg/L) 580 200 100 894 479 247<br />

Table 3: <strong>Salt</strong> Balance<br />

Cations Sodium Calcium Magnesium<br />

Water Flow Conc. Conc. Conc.<br />

Flow Description (m3/d) (meq/L) (meq/L) (meq/L)<br />

1 System feed 1000.00 25.23 9.98 8.23<br />

2 Stage 1 permeate 750.00 0.25 0.10 0.08<br />

3 Stage 1 concentrate 250.00 100.16 39.62 32.67<br />

4 Cat-IX effluent 250.00 172.45 0.00 0.00<br />

5 An-IX effluent 250.00 172.45 0.00 0.00<br />

6 Stage 2 permeate 225.00 1.72 0.00 0.00<br />

7 IX regeneration feed 25.00 1709.00 0.00 0.00<br />

8 Cat-IX regen waste 12.50 263.09 792.42 653.50<br />

9 An-IX regen waste 12.50 1709.00 0.00 0.00<br />

10 Liquid residuals 25.00 850.30 24.00 21.00<br />

11 Solid products 0.00 -- -- --<br />

12 System product water 975.00 0.59 0.08 0.06<br />

Anions Chloride Sulfate Carbonate<br />

Water Flow Conc. Conc. Conc.<br />

Flow Description (m3/d) (meq/L) (meq/L) (meq/L)<br />

1 System feed 1000.00 25.23 9.98 8.23<br />

2 Stage 1 permeate 750.00 0.25 0.10 0.08<br />

3 Stage 1 concentrate 250.00 100.16 39.62 32.67<br />

4 Cat-IX effluent 250.00 100.16 39.62 32.67<br />

5 An-IX effluent 250.00 172.45 0.00 0.00<br />

5