Nozzle<br />

Component<br />

Nozzle<br />

lever, lever<br />

guard, lever<br />

lock<br />

Nozzle<br />

Spout<br />

Nozzle Vent<br />

Hole<br />

Nozzle<br />

Collection<br />

Sleeve<br />

Nozzle Face<br />

Seal<br />

Nozzle<br />

Front‐End<br />

Kit<br />

(Collection<br />

sleeve <strong>and</strong><br />

face seal)<br />

Nozzle<br />

Interlock<br />

Rod<br />

Procedure<br />

Inspect for defects,<br />

cuts, or damage to<br />

the:<br />

• Nozzle Lever<br />

• Lever Guard<br />

• Lever Lock<br />

• Spout<br />

• Spout Vent Hole<br />

• Face Seal<br />

• Interlock Rod<br />

• Vapor Collection<br />

Sleeve.<br />

Section 10<br />

Section 11<br />

Fail<br />

Criteria<br />

NOZZLE<br />

Corrective<br />

Action<br />

VST EVR Total Balance System Solution<br />

Reference<br />

<strong>Manual</strong>s<br />

Damaged or missing Replace with new VST nozzle Section 10<br />

Sheared or bent<br />

Replace nozzle spout assembly with<br />

new VST spout or replace with new<br />

VST nozzle<br />

Vent hole blocked Clear blockage<br />

If greater than 18 inches<br />

total length of cuts (if<br />

greater than .375 sq. inches<br />

of material missing)<br />

Greater than 30% of the<br />

material is missing<br />

(if greater than 2.5 inches of<br />

the accumulated faceplate<br />

circumference is missing)<br />

Alignment lines are<br />

misaligned <strong>and</strong>/or the<br />

assembly is cockeyed<br />

Interlock rod sticks during<br />

engagement or<br />

disengagement<br />

Replace vapor collection kit<br />

Replace nozzle with new VST nozzle<br />

Section 10<br />

Section 11<br />

Section 10<br />

Section 11<br />

EO‐VR‐203: Exhibit 2<br />

Section 10<br />

EO‐VR‐203: Exhibit 2<br />

Authorized<br />

Personnel<br />

GDF Owner/Operator or<br />

VST ASC Levels A, B, or C<br />

VST ASC Levels A, B, or C<br />

GDF Owner/Operator or<br />

VST ASC Levels A, B, or C<br />

VST ASC Levels A, B, or C<br />

GDF Owner/Operator or<br />

VST ASC Levels A, B, or C<br />

Replace vapor collection kit Section 11 VST ASC Levels A, B, or C<br />

Replace nozzle with new VST nozzle<br />

Section 10<br />

Replace vapor collection kit Section 11<br />

Replace nozzle with new VST nozzle<br />

Replace vapor collection kit<br />

Replace nozzle with new VST nozzle<br />

Section 10<br />

Section 11<br />

Section 10<br />

GDF Owner/Operator or<br />

VST ASC Levels A, B, or C<br />

VST ASC Levels A, B, or C<br />

GDF Owner/Operator or<br />

VST ASC Levels A, B, or C<br />

VST ASC Levels A, B, or C<br />

GDF Owner/Operator or<br />

VST ASC Levels A, B, or C<br />

VST‐<strong>IOM</strong> / VR‐204‐A / Section 6 Daily Inspections 6‐2