<strong>TOCON</strong> <strong>selection</strong> <strong>guide</strong><br />

pre-amplified UV Photodetectors, 0 … 15V output<br />

What is a <strong>TOCON</strong>?<br />

A <strong>TOCON</strong> is a pre-amplified UV photodetector with 0…15V output. The <strong>TOCON</strong> devices<br />

are using modern hybride technology to cancel unwanted signal disturbances caused by<br />

moisture or electromagnetic radiation. The stable output voltage can be directly connected to a<br />

SPC controller or a voltage multimeter. No external amplifier is needed. Most of the <strong>TOCON</strong>s<br />

are powered by a Silicon Carbide (SiC) detector chip (ABC, A, E, C). The BLUE series works<br />

with a GaP chip. The <strong>TOCON</strong>s are available as:<br />

…3 pin photodiodes in<br />

a TO39 housing<br />

How to find „my“ <strong>TOCON</strong>?<br />

… or as easy to mount<br />

and connect stainless steel<br />

M12x1 thread housings,<br />

l = 32 mm, integrated plug<br />

Step 1 <strong>selection</strong> of Spectral Response<br />

<strong>TOCON</strong> NOMENCLATURE<br />

<strong>TOCON</strong> _ {spectral} {dynamic range}<br />

can be: ABC 1 …. 10<br />

A 1 …. 10<br />

E 1 …. 10<br />

C 1 …. 10<br />

BLUE 1 …. 10<br />

(“1” is very sensitive and “10” is very<br />

. unsensitive)<br />

The <strong>TOCON</strong>s are available with five different spectral responses, UV broadband “ABC”, UVA<br />

“A” , UVC “C” and Erythema Curve “E” (also useful for other selective UVB measuerements)<br />

and blue light “BLUE”. The below table shows the spectral response of the different <strong>TOCON</strong>s.<br />

For further information please refer to Appendix B (page 4) and the datasheet.<br />

Rev. 1.0 Page 1 [3]<br />

Manufacturer: sglux GmbH; Agent: <strong>Boston</strong> <strong>Electronics</strong>, 91 Boylston St, Brookline NA 02445 USA<br />

(800)347-5445 or (617)566-3821; fax (617)731-0935; uv@boselec.com ; www.boselec.com


<strong>TOCON</strong> <strong>selection</strong> <strong>guide</strong><br />

pre-amplified UV Photodetectors, 0 … 15V output<br />

Step 2 <strong>selection</strong> of Sensitivity Range<br />

The <strong>selection</strong> of the sensitivity range must be thoroughly done. A too sensitive <strong>TOCON</strong> will<br />

saturate below the upper limit of the radiation range to be measured, a too insensitive <strong>TOCON</strong><br />

gives no or a too low voltage output. Thus, for dynamic range <strong>selection</strong>, please estimate, better<br />

calculate what is the max. radiation your <strong>TOCON</strong> must measure without getting saturated (the<br />

sensor will not be damaged if saturated). The related min. radiation is lower by approx. factor<br />

15000 – if the <strong>TOCON</strong> is powered with 15V. It is possible to power the <strong>TOCON</strong> with lower<br />

voltages down to 2,5V. However, this will reduce the dynamic range by factor 15V/Vsupply. The<br />

below graph shows the sglux <strong>TOCON</strong> offer spread over a radiant intensity range of 13 orders<br />

of magnitude. The dynamic range is deternined by the numeric suffix from “1” = very sensitive<br />

for very low UV radiation (e.g. a flame) to “10” = very unsensitive for very strong radiation. For<br />

further information please refer to Appendix B (page 4) and the datasheet.<br />

If a higher dynamic range than 15000 is needed, the sglux DIGIPROBE sensors (digital sensor<br />

with 5 orders dynamic range) could be interesting.<br />

How to use a <strong>TOCON</strong>?<br />

The 0...15V output voltage of a <strong>TOCON</strong> can be directly connected to a voltmeter or a controller.<br />

Alternatively a controller of the sglux SENSOR MONITOR 5.0 series can be used. These modules are<br />

free programmable versatile Radiometer and Dosimeter modules with 3 programmable relay outputs. A<br />

data connection to a computer is available. The SENSOR MONITOR is perfectly suited for developers.<br />

Rev. 1.0 Page 2 [3]<br />

Manufacturer: sglux GmbH; Agent: <strong>Boston</strong> <strong>Electronics</strong>, 91 Boylston St, Brookline NA 02445 USA<br />

(800)347-5445 or (617)566-3821; fax (617)731-0935; uv@boselec.com ; www.boselec.com


<strong>TOCON</strong> <strong>selection</strong> <strong>guide</strong><br />

pre-amplified UV Photodetectors, 0 … 15V output<br />

General Specifications<br />

f<br />

Drawing<br />

Parameter Symbol Value Unit<br />

Maximum Ratings<br />

Operating Temperature Range Topt -25 … +85 °C<br />

Storage Temperature Range Tstor -40 … +100 °C<br />

Soldering Temperature (5s) Tsold 300 °C<br />

General Characteristics (T=25°C, Vsupply=+5 V)<br />

Supply voltage Vsupply 2,5 … 15,0 V<br />

Saturation voltage Vsat Vsupply V<br />

Dark offset voltage Voffset 0,5 mV<br />

Temperature coefficient Tc 405nm) VB >10 10 -<br />

Rev. 1.0 Page 3 [3]<br />

Manufacturer: sglux GmbH; Agent: <strong>Boston</strong> <strong>Electronics</strong>, 91 Boylston St, Brookline NA 02445 USA<br />

(800)347-5445 or (617)566-3821; fax (617)731-0935; uv@boselec.com ; www.boselec.com


<strong>TOCON</strong>-Series Summary<br />

Model<br />

UV broadband (SiC)<br />

<strong>Boston</strong> <strong>Electronics</strong> <strong>Corporation</strong><br />

91 Boylston St, Brookline MA 02445 USA<br />

(617)-566-3821 or (800)347-5445; fax (617)731-0935; uv@boselec.com<br />

The <strong>TOCON</strong> series are SiC UV photodiodes in TO-39 packages with hybrid<br />

preamplifiers inside.<br />

Tocons are available in a wide range of sensitivities corresponding to a wide<br />

range of potential customer requirements. Output is 0 to 15V. If 1 mV is the<br />

lower end of useful output, dynamic range is 15000:1 in any one device.<br />

Input is up to 15 VDC, lower input voltage (e.g. 5 VDC) is possible but reduces<br />

dynamic range.<br />

Optical input,<br />

W/cm 2 , for 2 V<br />

output<br />

at wavelength<br />

(nm)<br />

Approx. minimum<br />

irradiance (W/cm 2 )<br />

Approx. maximum<br />

irradiance (Vsupply =<br />

15 V) (W/cm 2 )<br />

Applications<br />

<strong>TOCON</strong>_ABC1 (nano) 7.0E-09 280 3.6E-12 5.4E-08 very low UV radiation detection, flame detection<br />

<strong>TOCON</strong>_ABC2 7.0E-08 280 3.6E-11 5.4E-07 low UV radiation detection, occupational safety<br />

<strong>TOCON</strong>_ABC3 7.0E-07 280 3.6E-10 5.4E-06 UV radiation detection, occupational safety<br />

<strong>TOCON</strong>_ABC4 (micro) 7.0E-06 280 3.6E-09 5.4E-05 UV irradiation measurement<br />

<strong>TOCON</strong>_ABC5 7.0E-05 280 3.6E-08 5.4E-04 UV irradiation measurement<br />

<strong>TOCON</strong>_ABC6 (sun) 7.0E-04 280 3.6E-07 5.4E-03 optimized for total sun UV measurements (not Erythema curve)<br />

<strong>TOCON</strong>_ABC7 (standard) 7.0E-03 280 3.6E-06 5.4E-02 UV irradiation measurement, industrial standard UV radiation<br />

<strong>TOCON</strong>_ABC8 7.0E-02 280 3.6E-05 5.4E-01 curing lamp control<br />

<strong>TOCON</strong>_ABC9 (mega) 7.0E-01 280 3.6E-04 5.4E+00 curing lamp control<br />

<strong>TOCON</strong>_ABC10 (giga) 7.0E+00 280 3.6E-03 5.4E+01 UV hardening control and other very high radiation sources<br />

UVA selective (SiC)<br />

<strong>TOCON</strong>_A1 7.0E-08 335 3.6E-11 5.4E-07 very low UVA radiation detection<br />

<strong>TOCON</strong>_A2 7.0E-07 335 3.6E-10 5.4E-06 low UVA radiation detection<br />

<strong>TOCON</strong>_A3 7.0E-06 335 3.6E-09 5.4E-05 UVA radiation detection<br />

<strong>TOCON</strong>_A4 7.0E-05 335 3.6E-08 5.4E-04 UVA irradiation measurement<br />

<strong>TOCON</strong>_A5 7.0E-04 335 3.6E-07 5.4E-03 UVA irradiation measurement<br />

<strong>TOCON</strong>_A6 7.0E-03 335 3.6E-06 5.4E-02 UVA irradiation measurement<br />

<strong>TOCON</strong>_A7 7.0E-02 335 3.6E-05 5.4E-01 Measurement of high UVA irradiation, curing lamp control<br />

<strong>TOCON</strong>_A8 7.0E-01 335 3.6E-04 5.4E+00 Measurement of very high UVA irradiation, curing lamp control<br />

<strong>TOCON</strong>_A9 (giga_A) 7.0E+00 335 3.6E-03 5.4E+01 Measurement of VERY high UVA irradiation, curing lamp control<br />

UVB selective (SiC) complies with CIE087, DIN5050<br />

1 UVI input produces electrical output of:<br />

<strong>TOCON</strong>_E1 1,7 V 0,01 UVI 3 UVI UV-Index measurements, if an attenuating diffusor is used<br />

<strong>TOCON</strong>_E2 (Eryca) 170 mV Erythema curve 0,1 UVI 30 UVI UV-Index measurements<br />

<strong>TOCON</strong>_E3 17 mV 5.00E-03 7.50E-01 UVB radiation measurements<br />

UVC selective (SiC) complies with DVGW W294(3), ONorm<br />

<strong>TOCON</strong>_C1 7.0E-09 254 3.6E-12 5.4E-08 very low UVC radiation detection, occupational safety<br />

<strong>TOCON</strong>_C2 7.0E-08 254 3.6E-11 5.4E-07 low UVC radiation detection, occupational safety<br />

<strong>TOCON</strong>_C3 7.0E-07 254 3.6E-10 5.4E-06 UVC radiation detection, occupational safety<br />

<strong>TOCON</strong>_C4 7.0E-06 254 3.6E-09 5.4E-05 UVC irradiation measurement<br />

<strong>TOCON</strong>_C5 7.0E-05 254 3.6E-08 5.4E-04 Purification lamp control<br />

<strong>TOCON</strong>_C6 (standard_C) 7.0E-04 254 3.6E-07 5.4E-03 Purification lamp control<br />

<strong>TOCON</strong>_C7 (kilo_C) 7.0E-03 254 3.6E-06 5.4E-02 Purification lamp control<br />

<strong>TOCON</strong>_C8 7.0E-02 254 3.6E-05 5.4E-01 curing lamp control<br />

<strong>TOCON</strong>_C9 7.0E-01 254 3.6E-04 5.4E+00 curing lamp control<br />

blue light (GaP) complies with 2006/25/EG<br />

<strong>TOCON</strong>_BLUE1 1.7E-05 445 8.4E-09 1.3E-04 measurement of very low blue light irradiation, occupational safety<br />

<strong>TOCON</strong>_BLUE2 (blue) 1.7E-04 445 8.4E-08 1.3E-03 measurement of low blue light irradiation, occupational safety<br />

<strong>TOCON</strong>_BLUE3 1.7E-03 445 8.4E-07 1.3E-02 measurement of blue light irradiation, occupational safety<br />

<strong>TOCON</strong>_BLUE4 1.7E-02 445 8.4E-06 1.3E-01 measurement of blue light irradiation, occupational safety<br />

<strong>TOCON</strong>_BLUE5 1.7E-01 445 8.4E-05 1.3E+00 measurement of high blue light irradiation, occupational safety<br />

<strong>TOCON</strong>_BLUE6 1.7E+00 445 8.4E-04 1.3E+01 measurement of very high blue light irradiation, occupational safety<br />

Accessories<br />

<strong>TOCON</strong>_probe<br />

Miniature threaded (M12x1) stainless steel housing with <strong>TOCON</strong> installed. Removable 5-pin connector with 2meter cable. Easy to mount and connect, with<br />

robust threaded body, suitable for all <strong>TOCON</strong>s<br />