03.03.2013 Views

ASCII Parameters S300/700 - Maccon.de

ASCII Parameters S300/700 - Maccon.de

ASCII Parameters S300/700 - Maccon.de

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ASCII</strong> Object Reference SERVOSTAR 300 & S<strong>700</strong><br />

<strong>ASCII</strong> -Command ANCNFG<br />

Available in <strong>S300</strong>/<strong>700</strong><br />

Syntax Transmit ANCNFG [Data]<br />

MMI CAN-Bus<br />

Syntax Receive<br />

Type<br />

ANCNFG <br />

Variable rw<br />

PROFIBUS Sercos<br />

Format Integer8<br />

SERCOS IDN:<br />

DIM -<br />

CAN Object No: 3507 (hex)<br />

Range 0 .. 14<br />

PROFIBUS PNU: 1607 (<strong>de</strong>c) IND = 1 (<strong>de</strong><br />

Default 0<br />

DPR Objekt Nr: 7<br />

Opmo<strong>de</strong> All<br />

Drive Status Disabled + Reset (Coldstart)<br />

Start Firmware 1.0<br />

Configuration Data Type BUS/DPR Integer8<br />

Function Group Analog I/O<br />

Weighting 10^3<br />

Short Description Configuration of analog input<br />

Description<br />

The ANCNFG command is used to configure the function of the analog inputs.<br />

Last Change of this Object 1.0<br />

EEPROM Yes<br />

Since the ANCNFG variable is used for the configuration of the instrument, the controller must be switched off and then on again<br />

after the variable has been changed (use |SAVE| first).<br />

Zustand Description<br />

ANCNFG=0 (Xcmd=Analog In 1) Analog In 1 is used as velocity setpoint or<br />

current setpoint <strong>de</strong>pending on the status of<br />

|OPMODE| (velocity in |OPMODE| =1; current in<br />

|OPMODE|=3). If one of the digital inputs is<br />

selected for |IN1TRIG|, |IN2TRIG|, |IN3TRIG| or<br />

|IN4TRIG|=8 (switch-over between Analog In 1<br />

and Analog In 2), Analog In 1 (input=low) or<br />

Analog In 2 (input=high) have the functionality.<br />

Scaling :<br />

Analog In 1 velocity Setpoint |VSCALE1|<br />

(|OPMODE|=1)<br />

Analog In 1 Current Setpoint |ISCALE1|<br />

(|OPMODE|=3)<br />

Analog In 2 velocity Setpoint |VSCALE2|<br />

(|OPMODE|=1)<br />

Analog In 2 Current Setpoint |ISCALE2|<br />

(|OPMODE|=3)<br />

ANCNFG=1 v_cmd=Analog In 1, Icmd=Analog In 2 Analog In 1 is used as velocity setpoint if<br />

|OPMODE| = 1 (scaling factor |VSCALE1|)<br />

Analog In 2 is used as current setpoint if<br />

|OPMODE| = 3 (scaling factor |ISCALE2|)<br />

ANCNFG=2 Analog In 1 = nsoll, Analog In 2 = Isoll Analog In 1 velocity setpoint<br />

Analog In 2 current feedforward<br />

(|OPMODE|=0,1) scaling factor |ISCALE2|<br />

ANCNFG=3 Xcmd=Analog In 1, Ipeak1=Analog In 2 Analog In 1 <strong>de</strong>pending on |OPMODE| velocity<br />

or current setpoint (scaling |VSCALE1| or<br />

|ISCALE1|)<br />

The absolute of Analog In 2 limits the current of<br />

the drive<br />

10V 100% of |IPEAK|<br />

5V 50% of |IPEAK|<br />

This current limit has effect to all used<br />

|OPMODE|<br />

<strong>ASCII</strong> Command ANCNFG Rev 2.4<br />

Page 18 / 729

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!