03.03.2013 Views

ASCII Parameters S300/700 - Maccon.de

ASCII Parameters S300/700 - Maccon.de

ASCII Parameters S300/700 - Maccon.de

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ASCII</strong> Object Reference SERVOSTAR 300 & S<strong>700</strong><br />

<strong>ASCII</strong> -Command MI2T<br />

Syntax Transmit MI2T [Data]<br />

Syntax Receive MI2T <br />

Type Variable ro<br />

Format Integer8<br />

DIM %<br />

Range 0 ... 100<br />

Default -<br />

Opmo<strong>de</strong> All<br />

Drive Status<br />

Start Firmware 1.0<br />

Function Group<br />

Short Description Motor I2T load<br />

Available in <strong>S300</strong>/<strong>700</strong><br />

MMI CAN-Bus<br />

PROFIBUS Sercos<br />

SERCOS IDN:<br />

CAN Object No: 35A4 (hex)<br />

PROFIBUS PNU: 1764 (<strong>de</strong>c) IND = 1 (<strong>de</strong><br />

DPR Objekt Nr: 164<br />

Configuration Data Type BUS/DPR Integer8<br />

Weighting 10^3<br />

Last Change of this Object 1.0<br />

EEPROM No<br />

Description<br />

This variable returns the average current as a percentage of the continuous current (see |MICONT|). The average current is filtered<br />

with the time constant |MTIME|.<br />

<strong>ASCII</strong> Command MI2T Rev 2.4<br />

Page 386 / 729