Starting Battery<br />

Battery Capacity<br />

DC Charging Alternator<br />

Starter<br />

Starting Aid<br />

DC No-Load Cu rrent<br />

DC Cranking Current<br />

General- Single Phase<br />

Voltage - Single Phase<br />

Voltage regulation:<br />

Frequency regulation:<br />

Rating (Volts AC)<br />

SPECIFICATIONS<br />

WESTERBEKE 25 KW BEDA GENERATOR<br />

ELECTRICAL SYSTEM AC GENERATOR (3 Phase)<br />

12-Volt. (-) negative ground<br />

400 - 600 Cold Cranking Amps (CCA)<br />

51 Amp rated, belt-driven<br />

12-Volt, Reduction Gear<br />

Glow plugs, sheathed type<br />

± 2% of rated Amps<br />

250 - 300 Amps (engine cold)<br />

AC GENERATOR (SINGLE PHASE)<br />

Brushless, four-pole, revolving field Sealed<br />

lubricated single bearing design.<br />

Reconnectable single phase for 120/240 volts<br />

with solid state voltage regulator.<br />

120 or 120/240 Volts - 60 Hertz<br />

220 Volts - 50 Hertz<br />

± 2% no load to full load.<br />

.3 Hertz no load to tuilioad.<br />