<strong>Spiegelberg</strong>:<br />

<strong>ICP</strong>-<strong>Monitor</strong><br />

<strong>HDM</strong> <strong>29.1</strong><br />

<strong>Operating</strong> <strong>Instructions</strong><br />

<strong>Monitor</strong>ing<br />

Technology for<br />

Brains<br />

1


2<br />

<strong>Spiegelberg</strong>:<br />

EG-Konformitätserklärung<br />

EC Declaration of Conformity<br />

Die <strong>Spiegelberg</strong> (GmbH & Co.) KG erklärt als Hersteller in alleiniger Verantwortung,<br />

dass die im folgenden genannten Produkte die Anforderungen der Richtlinie<br />

93/42/EG erfüllen. Das Qualitätsmanagementsystem entspricht den Forderungen<br />

der Norm EN ISO 13485:2003 + AC:2009.<br />

<strong>Spiegelberg</strong> (GmbH & Co.) confirms as the manufacturer, being solely responsible,<br />

that the following products meet the requirements according to the Medical<br />

Device Directive 93/42/EEC. The Quality Management System is in accordance with<br />

the requirements of the standard EN ISO 13485:2003 + AC:2009.<br />

Produkt: <strong>ICP</strong>-<strong>Monitor</strong><br />

Product:<br />

REF: <strong>HDM</strong><strong>29.1</strong><br />

Gültig ab: SN: 155/10<br />

Valid from:<br />

Angewandte produktspezifische Normen: DIN EN 60601-1:1996<br />

Applied product-specific standards:<br />

Klassifizierung gem. 93/42/EG IIa<br />

Classification acc. 93/42/EEC<br />

Zertifikate: 018737 MP29, 018737 MR2<br />

Certificates:<br />

Gültig bis: 2015-10-24<br />

Valid until:<br />

Benannte Stelle: DQS GmbH<br />

Notified Body: August-Schanz-Strasse 21<br />

60433 Frankfurt am Main<br />

Germany<br />

Benannte Stelle Nr.: 0297<br />

Notified Body No.:<br />

Dr. Andreas <strong>Spiegelberg</strong><br />

Geschäftsführer<br />

Hamburg, 24.11.2010<br />

<strong>Spiegelberg</strong> Persönlich haftende<br />

(GmbH & Co.) KG Gesellschafterin:<br />

Tempowerkring 4 <strong>Spiegelberg</strong><br />

21079 Hamburg Medizintechnik GmbH<br />

Germany Hamburg<br />

Geschäftsführer:<br />

Dr. A. <strong>Spiegelberg</strong><br />

Registergericht Registergericht<br />

Hamburg HRB 81393 Hamburg HRB 46157


4<br />

Contents<br />

Safety instructions<br />

Indication and Method<br />

<strong>Monitor</strong> Operation<br />

Cleaning<br />

Connections<br />

Faults<br />

Technical Specifications<br />

Approved Accessories<br />

Symbols used<br />

5<br />

6<br />

6<br />

8<br />

9<br />

10<br />

11<br />

13<br />

15


Safety <strong>Instructions</strong><br />

The <strong>ICP</strong>-<strong>Monitor</strong> and the accompanying<br />

probes are designed for the<br />

measurement of intracranial<br />

pressure. The manufacturer accepts<br />

responsibility for the safety,<br />

reliability and performance of the<br />

monitor only if:<br />

- the installation, extensions,<br />

readjustments, modifications and<br />

repairs are performed by<br />

authorized personnel,<br />

- the monitor is used in<br />

accordance with the operating<br />

instructions, and<br />

- the monitor is used with the<br />

approved accessories.<br />

Attention<br />

The device is not intended for use in<br />

areas where there is a danger of<br />

explosion.<br />

Attention<br />

The device may be repaired only by<br />

persons or companies that are<br />

authorized to do so.<br />

Attention<br />

The device is not intended for use<br />

during Electro-Surgery/Diathermy.<br />

Attention<br />

Grounding reliability can only be<br />

achieved if the device is connected<br />

to an equivalent power cord marked<br />

„hospital grade“ or „hospital only“.<br />

Attention<br />

It must be ensured that the<br />

classification of all connected<br />

devices is suitible to the application<br />

with regards to safety against<br />

electric shock. The fact that leakage<br />

currents are amplified if more than<br />

one devices are connected to a<br />

patient must be taken into account.<br />

5<br />

Attention<br />

It is the sole responsibility of the user<br />

to check that the electric installation<br />

is in compliance with the local and<br />

hospital-specific safety regulations<br />

and that the system is in compliance<br />

with the standard DIN EN 60601-1-1<br />

„General standards, safety<br />

regulations for electro-medical<br />

devices“.


6<br />

Indication and Method<br />

The <strong>ICP</strong>-<strong>Monitor</strong> and the probes are<br />

intended for the monitoring of<br />

intracranial pressure in the ventricle,<br />

in the parenchyma, subdurally, or<br />

epidurally.<br />

The Air-Pouch system consists of a<br />

hollow body connected to a<br />

pressure transducer by tubing. The<br />

pressure transducer, the electronic<br />

hardware, and the device for filling<br />

the Air-Pouch are integrated in<br />

the <strong>ICP</strong>-<strong>Monitor</strong>.<br />

For intraventricular or<br />

intraparenchymal pressure<br />

measurement the Air-Pouch is<br />

placed in the ventricle or in the<br />

parenchyma respectively. For<br />

epidural or subdural pressure<br />

measurements the Air-Pouch is<br />

placed on the dura or under the<br />

dura of the patient.<br />

<strong>Monitor</strong> Operation<br />

Make sure the correct mains voltage<br />

is selected.<br />

If selection of the voltage needs to<br />

be changed, it can be selected after<br />

opening of the cover of the selector<br />

next to the power cord socket.<br />

After changing the voltage, the<br />

fuses need to be changed according<br />

to the plate.<br />

The intracranial pressure is<br />

transmitted across the thin pouch<br />

wall to the air volume in the pouch<br />

and transformed into an electric<br />

signal by the pressure transducer.<br />

On the digital display the mean <strong>ICP</strong><br />

and the systolic and diastolic <strong>ICP</strong> are<br />

shown. At the monitor output both<br />

the mean pressure and the pulsatile<br />

signal are available.<br />

Once every hour the <strong>ICP</strong>-<strong>Monitor</strong><br />

opens the pressure transducer to<br />

atmospheric pressure for zero<br />

adjustment. The Air-Pouch is<br />

then filled with the exact air<br />

volume.


Connect the power cord to the<br />

monitor and to a power outlet. The<br />

power control lamp indicates mains<br />

operation and charging of the<br />

battery.<br />

The battery is charged both in<br />

operation and switched off. The<br />

battery cannot be overcharged.<br />

After placement of probe the tube<br />

connector is inserted into the<br />

monitor socket and fastened by a<br />

slight clockwise turn. The soft<br />

material of the connector<br />

guarantees air-tightness.<br />

<strong>Monitor</strong>ing is started by pushing the<br />

button marked I/O. No manual zero<br />

adjustment or calibration is<br />

required.<br />

7


8<br />

On the digital display the mean <strong>ICP</strong><br />

is shown in mmHg. Systolic and<br />

diastolic <strong>ICP</strong> are also displayed.<br />

The battery state indicator shows<br />

the charging state of the battery.<br />

Cleaning<br />

After removal of the power cord<br />

the unit can be wiped off with a<br />

damp rag using a common<br />

disinfectant. No liquid whatsoever<br />

must be introduced into the<br />

catheter or into<br />

the connector of the monitor.<br />

Attention<br />

Unplug the power cord<br />

prior to cleaning.<br />

Attention<br />

No fluid should be<br />

allowed to enter the<br />

probe connector.<br />

Attention<br />

In case of unintentional<br />

wettening of the device,<br />

the power cord is to be<br />

disconnected<br />

immediately.


Connections<br />

Connection of a Patient<br />

<strong>Monitor</strong><br />

To connect a patient monitor the<br />

connecting cable is inserted into the<br />

socket of the <strong>ICP</strong>-<strong>Monitor</strong> marked<br />

<strong>Monitor</strong> and connected to the<br />

pressure transducer input of the<br />

patient monitor.<br />

Zero Adjustment of the<br />

Patient <strong>Monitor</strong><br />

Push the button marked Zero. A<br />

blinking „0.0“ ist displayed. Zero<br />

patient monitor using the zero<br />

button whilst the blinking „0.0“ is<br />

displayed.<br />

Connection of a CPP-<strong>Monitor</strong><br />

Connect the socket marked RS 232<br />

of the <strong>ICP</strong>-<strong>Monitor</strong> to the RS 232<br />

<strong>ICP</strong> socket of the CPP-<strong>Monitor</strong>.<br />

Connection of a Device with<br />

Voltage Input<br />

To connect a device with voltage<br />

input, the appropriate cable is<br />

connected with the socket marked<br />

„<strong>Monitor</strong>“ of the <strong>ICP</strong>-<strong>Monitor</strong> and<br />

the input socket of the device.<br />

Connection of a Computer<br />

The computer is connected to the<br />

socket marked RS 232.<br />

Attention<br />

The <strong>ICP</strong>-<strong>Monitor</strong> must only be used<br />

with monitors and devices, that are<br />

CE-marked and approved as an<br />

electro-medical device.<br />

9


10<br />

Faults<br />

The air-tightness of the Air-Pouch<br />

system is checked regularly. If a leak<br />

is detected, the red warning<br />

indicator shows alarm. When the<br />

leak is removed the red warning<br />

indicator disappears and the<br />

measurement is continued. If the<br />

leak has not been removed after<br />

one minute, in addition to the<br />

alarm display a chirp sound is<br />

emitted. To reset the alarm the<br />

monitor must be switched off and<br />

on again. The chirp sound stops<br />

after one minute, unless the<br />

monitor has been switched off<br />

before, and the digital display<br />

disappears. The warning<br />

indicator continues to flash.<br />

If a pressure limit is exceeded during<br />

probe filling the filling process is<br />

interrupted, the digital display<br />

shows ´E1´ and the chirp sound is<br />

emitted. This can happen if the airpouch<br />

resists unfolding or if the<br />

tube is clamped. Switching off and<br />

on the monitor resets the system.<br />

If the digital display shows<br />

´E2´....´E9´ during operation an<br />

internal fault has been detected.<br />

Contact the service in this case.<br />

Attention<br />

The unit cannot be<br />

repaired by the user.


Technical Specifications<br />

REF<br />

Measurement range<br />

<strong>Operating</strong> voltage<br />

Current requirement<br />

Fuses<br />

Voltage output<br />

Pressure monitor output<br />

RS 232 C interface<br />

Displays<br />

Battery<br />

Battery Lifetime<br />

Running time on battery<br />

Charging time<br />

Classifications<br />

Weight<br />

In accordance with standards<br />

Product lifetime<br />

Maintenance<br />

Battery Maintenance<br />

Conditions for storage<br />

Conditions for operation<br />

Disposal of product<br />

11<br />

<strong>HDM</strong> <strong>29.1</strong><br />

-50 to +100 mmHg<br />

230 V~, 50/60 Hz<br />

115 V~, 50/60 Hz<br />

0,1 A at 230 V~<br />

0,2 A at115 V~<br />

125 mA T at 230 V~<br />

250 mA T at 115 V~<br />

1V/50 mmHg at 1 kΩ<br />

5 µV/mmHg/V<br />

9600 Bd<br />

Mean <strong>ICP</strong><br />

Systolic <strong>ICP</strong><br />

Diastolic <strong>ICP</strong><br />

Battery state<br />

Power<br />

NiMH; 7,2 V; 1,6 Ah<br />

24 months<br />

3 h<br />

2-8 h<br />

Accuracy class 2<br />

Safety class I / BF, permanent<br />

operation<br />

IP 20 acc. IEC 529<br />

Not AP, not APG<br />

Not for use during Electro-Surgery/<br />

Diathermy<br />

General Medical Equipment<br />

3kg<br />

IEC 60601-1<br />

IEC 60601-1-2<br />

IEC 60601-1-34<br />

10 Years<br />

None<br />

None<br />

-10°C - 70°C,10% - 90% rel. hum.<br />

0°C - 35°C,10% - 90% rel. hum.<br />

Contact us


12<br />

Pinout of RS 232 Socket<br />

2: RxD<br />

3: TxD<br />

7: Gnd<br />

Data Transmission across<br />

the RS 232 C Interface<br />

The <strong>ICP</strong>-<strong>Monitor</strong> responds to single<br />

ASCII bytes:<br />

To the monitor<br />

´A´<br />

´B´<br />

´C´<br />

Pinout of <strong>Monitor</strong> Socket<br />

1: Uref Input<br />

5: Analog Output<br />

6: Uref Output (2,5 V)<br />

9: Analog Gnd.<br />

For use as a voltage output<br />

pins 1 and 6 are connected by a<br />

jumper.<br />

For use as a monitor output the<br />

excitation voltage is fed into the<br />

reference input and the analog<br />

output is scaled down by a resistive<br />

divider.<br />

Response<br />

Mean pressure in ASCII string<br />

format, terminated by<br />

´Carriage Return´.<br />

Mean pressure in binary<br />

format, 1/10 mm Hg resolution,<br />

two´s complement, two<br />

bytes, high byte first.<br />

Instantaneous pressure in<br />

binary format, 1/10 mm Hg<br />

resolution, two´s complement,<br />

two bytes, high byte first. Response<br />

only after new value is<br />

read in (every 10 ms).


Approved Accessories<br />

Description<br />

CPP-<strong>Monitor</strong><br />

Compliance-<strong>Monitor</strong><br />

<strong>Spiegelberg</strong>-Probes<br />

Interconnect Cable for<br />

CPP 21.x or CMP 27.x<br />

<strong>Monitor</strong> Cables<br />

B.Braun/Lohmeier<br />

Criticare<br />

Datex-Cardiocap<br />

Datascope<br />

Digicare<br />

Dixtal<br />

Hellige 5. Generation<br />

Hewlett-Packard/Philips<br />

Marquette<br />

Mindray<br />

Nihon-Kohden BMS 2301<br />

Nihon-Kohden Lifescope<br />

Ohmeda<br />

Propaque/Mennen<br />

Siemens/Dräger 10 pins<br />

Siemens/Dräger 16 pins<br />

Siemens/Dräger 7 pins<br />

Space-Labs<br />

REF<br />

CPP 21.x<br />

CMP 27.x<br />

SND 13.x.xx<br />

SND 32.x.xx<br />

KBL 21.005.00<br />

KBL 13.027.01<br />

KBL 13.037.01<br />

KBL 13.007.00/FV608<br />

KBL 13.026.01<br />

KBL 13.039.01<br />

KBL 13.042.01<br />

KBL 13.003.00/FV609<br />

KBL 13.004.00/FV610<br />

KBL 13.005.00/FV612<br />

KBL 13.038.01<br />

KBL 13.029.01<br />

KBL 13.035.01<br />

KBL 13.022.00/FV616<br />

KBL 13.009.00/FV617<br />

KBL 13.002.00/FV620<br />

KBL 13.024.01<br />

KBL 13.028.01<br />

KBL 13.006.00/FV622<br />

10<br />

13


14<br />

Cables for Devices<br />

with Voltage Input<br />

BNC-Plug<br />

Banana Plug 4 mm<br />

Computer Cable RS 232 9-pin<br />

150 cm<br />

25 cm<br />

Attention<br />

The <strong>ICP</strong>-<strong>Monitor</strong> must only be used<br />

with monitors and devices, that are<br />

CE-marked and approved as an<br />

electro-medical device.<br />

KBL 13.030.00/FV654<br />

KBL 13.031.00/FV653<br />

KBL 13.033.00/FV656<br />

KBL 13.033.01


Symbols used<br />

~ Attention<br />

Alternating current<br />

Fuse<br />

Equipotential<br />

Applied part type BF<br />

Mains control lamp<br />

Separate collection<br />

On / Off<br />

15


16<br />

<strong>Spiegelberg</strong><br />

(GmbH & Co.) KG<br />

Tempowerkring 4<br />

21079 Hamburg<br />

Germany<br />

Phone: +49-40-790-178-0<br />

Fax: +49-40-790-178-10<br />

Email: info@spiegelberg.de<br />

http://www.spiegelberg.de<br />

© by <strong>Spiegelberg</strong> (GmbH & Co.) KG, 2006<br />

0297<br />

Technical alterations reserved.<br />

Version: 4 / 2012-12-02