26.03.2013 Views

wall mounted cast iron, gas fired boiler for central heating ... - Ferroli

wall mounted cast iron, gas fired boiler for central heating ... - Ferroli

wall mounted cast iron, gas fired boiler for central heating ... - Ferroli

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Sigma<br />

12 13 14<br />

Fig. 18 Fig. 19 Fig. 20<br />

Install the inner metal flue "a" into the<br />

adapter "b".<br />

2.05 Top outlet fl u e conversion<br />

1<br />

Fig. 21a<br />

Remove fan by pulling off electrical connections. Pull off air<br />

pressure switch tubes from the air pressure switch. Remove<br />

the two screws "b" and rotate the fan upward to disengage<br />

it from the securing pin "a".<br />

3<br />

Fig. 22a<br />

Take off the four screws which fix the top sealed chamber<br />

cover, remove the cover and <strong>gas</strong>ket.<br />

Lift <strong>boiler</strong> with flue pipe in place,<br />

engage inner and outer flue, slide into<br />

position.<br />

2<br />

Fig. 21b<br />

4<br />

Fig. 22b<br />

Make sure the inner flue is fully engage<br />

in the flue terminal, secure <strong>boiler</strong> with<br />

two nuts and washers "a" and "b".<br />

Rotate the fan upward to disengage it from the securing<br />

pin "a". Remove the securing screw that locates the<br />

fan nozzle extension to the fan and remove the nozzle<br />

extension.<br />

Rotate the cover and <strong>gas</strong>ket through 90° and fit it to<br />

the rear of the <strong>boiler</strong> to cover the original flue outlet.<br />

Secure them both in place with the four screws removed