Sigma<br />

2.06 Top outlet Flue Connection<br />

Three different connection are available from top of the <strong>boiler</strong>, using accessories as reported on fig. 30a, b e c and<br />

on examples a next page.<br />

1 Top outlet horizontal 2 Top outlet two 3<br />

2.06.01 Examples of top fl ue connection<br />

1 Example of concentric flue Ø 100<br />

with appliance bend use<br />

Fig. 31<br />

Note • Bear in mind that the two concentric<br />

pipes must slope downwards away from the<br />

<strong>boiler</strong> at a rate of about 3 mm/m to avoid<br />

rainwater entering the <strong>boiler</strong>. Outside, the<br />

pipes should protrude from the <strong>wall</strong> between<br />

10 and 60 mm.<br />

Warning • Back exit with coaxial bend is<br />

not possible<br />

concentric fl ue<br />

Vertical Connection, concentric bend<br />

and two pipe separator can be<br />

supplied on request.<br />

2 Example of direct roof flue outlet<br />

and <strong>wall</strong> air inlet with 2 pipe system<br />

Fig. 32<br />

pipe system<br />

Fig. 30a Fig. 30b Fig. 30c<br />

Warning • Back exit with Air/Flue T separator<br />

is not possible<br />

Top outlet vertical<br />

concentric fl ue<br />

3 Example of concentric flue Ø 100<br />

with vertical outlet flue use.<br />

Fig. 33<br />

Fig. 30