Sigma<br />

No spark to the electrode During the ignition phase, there is no spark to the electrode<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Burner goes out Insufficient <strong>gas</strong> supply<br />

Boiler dirty<br />

<br />

Burner or injector dirty<br />

<br />

Faulty flow temperature sensor<br />

<br />

<br />

Boiler operates but Incorrect <strong>gas</strong> pressure<br />

temperature fails to <br />

rise<br />

Boiler dirty<br />

Boiler inadequate<br />

<br />

<br />

Condensate in <strong>boiler</strong> Thermostat set too low<br />

<br />

Incorrect <strong>gas</strong> rate<br />

<br />

<br />

Boiler sooting Faulty flame adjustment<br />

<br />

<br />

Burner air ports blocked<br />

<br />

Radiators cold in winter Faulty flow temperature sensor<br />

Room thermostat set too low or faulty<br />

<br />

Pump is stuck and fails to rotate<br />

<br />

<br />

<br />

The pump does not rotate