Metal Panels<br />

<strong>2005</strong>-<strong>2006</strong> Steep-<strong>slope</strong> <strong>Roofing</strong> Materials Guide 188<br />

1. COMPANY NAME INTEGRIS METALS<br />

2. PRODUCT NAME COLORKLAD SYSTEM I<br />

3 CONFIGURATION<br />

3.1 STYLE<br />

Simulated Shingle (specific type if applicable)<br />

Simulated Shake (specific type if applicable)<br />

Simulated Slate (specific type if applicable)<br />

Simulated Tile (specific type if applicable)<br />

Other (specify type) STANDING SEAM<br />

3.2 COMPONENT TYPE AND SIZE<br />

Panel [width (in.), maximum length (ft.)]<br />

Individual (dimensions: inches x inches)<br />

12, 16, 18, 22 X 40<br />

3.3 MATERIALS, THICKNESSES, AND FINISHES<br />

GALVANIZED STEEL (ga.): Thicknesses 24<br />

Finishes KYNAR 500, MILL<br />

STAINLESS STEEL (ga.) Thicknesses 24, 26<br />

Finishes MILL<br />

GALVALUME (ga.) Thicknesses 24<br />

Finishes<br />

ALUMINIZED STEEL (ga.) Thicknesses<br />

Finishes<br />

MILL<br />

ALUMINUM (in.) Thicknesses 0.032<br />

Finishes KYNAR 500<br />

COPPER (oz.) Thicknesses 16, 20<br />

Finishes MILL<br />

TERNE METAL (ga.) Thicknesses 24, 26, 28, 30<br />

Finishes<br />

ZINC (ga.) Thicknesses<br />

Finishes<br />

MILL<br />

4. SYSTEMS RECOMMENDATIONS<br />

Min. Slope Recommended In Normal Application (in. per ft.)<br />

Min. Slope Recommended In Special Application (in. per ft.)<br />

DECK TYPES'<br />

3:12<br />

Solid Deck, Wood<br />

Spaced Sheathing, Wood<br />

Decking Not Required<br />

X<br />

Underlayment Recommended (type or NA) 30 LB. FELT<br />

5. PANEL CONFIGURATION (For components in item 3.2A above; for individual components, see item 6.)<br />

5.1 INTERLOCKING METHOD, HEIGHT (inches), AND SEAM SEALANT<br />

Overlapped<br />

Interlocked<br />

Slip Locked<br />

HEIGHT (inches) / SEAM SEALANT (F = Factory<br />

Applied; E = Field applied; N = None)<br />

Snap Together 1, 1-1/2 / E, N<br />

5.2 FASTENING METHOD<br />

Through Fastened (exposed or concealed, specify)<br />

Clip (exposed or concealed, specify) CONCEALED<br />

6. INDIVIDUAL COMPONENT CONFIGURATION (For components in item 3.2B above; for panels, see item 5.)<br />

6.1 DIMENSIONS<br />

Weight Per Roof Square (pounds)<br />

Exposure (inches)<br />

Coverage (approx. no. of pieces per square at listed exposure)<br />

6.2 INSTALLATION PROCESSING<br />

Through-Fastened (exposed or concealed, specify)<br />

Kind(s) Of Fastener Required (nails, staples, screws, NA)<br />

Number Of Fasteners Per Piece (number or NA)<br />

Seam Snap-In Or Interlock (specify or NA)<br />

Adhesive/Sealant Required (yes/no)<br />

Support Battens Required (yes/no)<br />

7. MANUFACTURER/PRODUCT DATA<br />

Year Product First Sold 1969<br />

Number of Squares Installed --<br />

Method Of Distribution (distributors, direct) DISTRIBUTORS & DIRECT<br />

Number Of Regional Service Locations 100<br />

Licensed Applicator Agreement (yes/no) NO<br />

For Sales Information, Contact R. OEHME<br />

For Technical Information, Contact R. OEHME<br />

8.<br />

ASTM E331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by<br />

Uniform Static Air Pressure Difference (results or none)<br />

ASTM E1646, Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform<br />

Static Air Pressure Difference (results or none)<br />

NONE<br />

ASTM E283, Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain<br />

Walls, and Doors Under Specified Pressure Difference Across the Specimen (results or none)<br />

ASTM E1680, Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems<br />

(results or none)<br />

ASTM E 330, Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors<br />

by Uniform Static Air Pressure Difference (results or none)<br />

ASTM E 1592, Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by<br />

Uniform Static Air Pressure Difference (results or none)<br />

FM 4471, Approval Standard for Class 1 Panel Roofs (results or none)<br />

UL 580, Test for Uplift Resistance of Roof Assemblies (results or none)<br />

UL 1897, Uplift Test For Roof Covering Systems (results or none)<br />

NONE<br />