Underlayment Sheets<br />

<strong>2005</strong>-<strong>2006</strong> Steep-<strong>slope</strong> <strong>Roofing</strong> Materials Guide 234<br />

1. COMPANY NAME CERTAINTEED DEWITT PRODUCTS DEWITT PRODUCTS<br />

CORPORATION COMPANY COMPANY<br />

2. PRODUCT NAME OR DESCRIPTION #30 ROOF SHIELD 67 LITE 'N SMOOTH<br />

PLAIN FELT - UL ICE & WATER ICE & WATER<br />

3. PRODUCT CATEGORY<br />

A. Organic Asphalt-Saturated Felt, Unperforated X<br />

B. Organic Asphalt-Saturated Felt, Coated<br />

C. Aspahlt Fiberglass Felt<br />

D. Special "Ice Shield" Underlayment X X<br />

4A.<br />

PRODUCT INFORMATION (FOR PRODUCTS IN CATEGORY 3A, 3B,<br />

OR 3C)<br />

Type (ASTM standard [specify] or generic)<br />

Available as Sepcialty Underlayment (type, e.g., shake felt)<br />

TYPE II (D 266)<br />

Sheet Width (inches) 36<br />

Size Per Roll (sq. ft.) 216<br />

Weight Per Roll (pounds) 54<br />

4B. PRODUCT INFORMATION (FOR PRODUCTS IN CATEGORY 3D)<br />

Kind of Sheet(s) (e.g., felts, modified bitumen) MODIFIED BITUMEN MODIFIED BITUMEN<br />

Number Of Ply(ies)/Sheets Comprising Underlayment 1 1<br />

Waterp<strong>roofing</strong> Medium (e.g., asphalt, modified asphalt) MODIFIED ASPHALT MODIFIED ASPHALT<br />

Application Method (e.g., mechanical, mopped, self-adhered) SELF-ADHERED SELF-ADHERED<br />

Sheet Width (inches) 36 36<br />

Size Per Roll (sq. ft.) 200 200<br />

Weight Per Roll (pounds) 76 LBS 57 LBS.<br />

5. AVAILABILITY RESTRICTED REGIONALLY (yes/no) YES NO NO<br />

6. RECOMMENDED FOR APPLICATION WITH:<br />

Asphalt Shingles X X X<br />

Fiber-Cement Roof Components X X<br />

Clay Tile X<br />

Concrete Tile X X<br />

Metal Roof Components X<br />

Slate X X<br />

Wood Shakes/Shingles<br />

Other (specify)<br />

X<br />

7. YEAR PRODUCT FIRST SOLD 1989 1996<br />

8. NUMBER OF SQUARES INSTALLED<br />

9. DISTRIBUTION<br />

Distributors (number handling product or no) UNLIMITED UNLIMITED<br />

Direct (number of regional service locations or no) 2 2<br />

10. UL-CLASSIFIED PREPARED ROOFING ACCESSORY (yes/no)<br />

COMPLIES WITH:<br />

YES YES YES<br />

11A. ASTM D 224–89 STANDARD SPECIFICATION FOR SMOOTH-<br />

SURFACED ASPHALT ROLL ROOFING (ORGANIC FELT ) (type or NA)<br />

Type I–Minimum net mass per unit area of <strong>roofing</strong>, 39.8lb/100 sq. ft<br />

Type II–Minimum net mass per unit area of <strong>roofing</strong>, 54.6 lb/100 sq. ft<br />

Type III–Minimum net mass per unit area of <strong>roofing</strong>, 51.1lb/100 sq. ft<br />

Type IV–Minimum net mass per unit area of <strong>roofing</strong>, 39.8 lb/100 sq. ft.<br />

11B. SATURATED ORGANIC FELT USED IN ROOFING &<br />

WATERPROOFING ( type or NA)<br />

Type I–Commonly called No. 15 asphalt felt<br />

NA<br />

Type II–Commonly called No. 30 asphalt felt<br />

11C. ASTM D 2626–97 STANDARD SPECIFICATION FOR ASPHALT-<br />

X<br />

SATURATED AND COATED ORGANIC FELT BASE SHEET USED IN<br />

ROOFING (yes, no or NA)<br />

11D. ASTM D 4869–88 (1993) STANDARD SPECIFICATION FOR ASPHALT -<br />

SATURATED ORGANIC FELT SHINGLE UNDERLAYMENT USED IN<br />

ROOFING (type or NA)<br />

Type I–Shingle Underlayment<br />

Type II–Heavy Duty Shingle Underlayment<br />

11E. ASTM D 1970–00 STANDARD SPECIFICATION FOR SELF-ADHERING<br />

YES<br />

POLYMER MODIFIED BITUMINOUS SHEET MATERIAL USED AS<br />

STEEP ROOFING UNDERLAYMENT FOR ICE DAM PROTECTION (yes,<br />

no, or NA)<br />

NA YES YES<br />

11F. OTHER ASTM SPECIFICATION (specify)<br />

12. ACCEPTED BY THE FOLLOWING CODES ICBO,<br />

MIAMI-DADE CNTY, FL<br />

ICBO 4887 ICBO 4887<br />

13. FOR SALES INFORMATION, CONTACT: LOCAL OFFICE 800/962-8599 800/962-8599<br />

FOR TECHNICAL INFORMATION, CONTACT: 800/322-3060 800/962-8599 800/962-8599<br />

14. SEE APPENDIX IF CHECKED<br />