2 GENERAL INFORMATION<br />
2.1 COMPRESSOR RANGES<br />
Doc. Code Emission Revision Date Page<br />
MP01E 2000-04 0 20-02 13 - 98<br />
COMPRESSORS<br />
HANDBOOK<br />
Chapter<br />
GENERAL INFORMATION<br />
Table 1 indicates the refrigerant types used in the compressors available on catalog for each series<br />
and according to the different applications.<br />
Table 1 <strong>Compressor</strong> Series - Application - Refrigerants<br />
SERIES<br />
APPLICATION<br />
LBP MBP HBP AC<br />
EM<br />
–<br />
R134a - R600a - R404A - R290 R404A - R290 R134a - R600a –<br />
NB<br />
R134a - R600a - R404A -<br />
R507<br />
R404A - R507 R22 - R134a –<br />
NE<br />
R22 - R134a - R404A - R507 -<br />
R290<br />
R404A - R507<br />
R290<br />
R22 - R134a -<br />
R600a<br />
R22 - R407C<br />
T - NT<br />
R22 - R134a - R404A - R507 - R404A - R507<br />
R290<br />
R290<br />
R22 - R134a -<br />
R22 - R407C<br />
NJ R22 - R134a - R404A - R507 R404A - R507 R22 - R134a R22 - R407C<br />
The available models in the different applications, the thermodynamic and electrical performances,<br />
the external dimensions and the approved electrical components, are listed in the General Catalog,<br />
Technical Bulletin, Electrical Components Catalog and Electronic Catalog, which<br />
complement this <strong>Handbook</strong>.<br />
2.2 APPLICATIONS<br />
Table 2 Applications<br />
TYPE DESCRIPTION<br />
(Low Back Pressure)<br />
Models at low evaporating temperatures, suitable for applications with working<br />
LBP<br />
evaporating temperatures lower than -20 °C; for instance refrigerators, freezers,<br />
frozen food cabinets, frozen food display cases, display windows, etc.<br />
(Medium Back Pressure)<br />
Models for medium evaporating temperatures, suitable for applications with work-<br />
MBP<br />
ing evaporating temperatures higher than -20 °C; such as fresh food cabinets, drink<br />
coolers, ice makers etc.<br />
(High Back Pressure)<br />
Models at high evaporating temperatures, suitable for applications with working<br />
HBP<br />
evaporating temperatures higher than -15 °C; such as fresh food cabinets, drink<br />
coolers, ice makers, dehumidifiers etc.<br />
(Air Conditioning)<br />
Models for air conditioning with R22, suitable for applications with positive work-<br />
AC<br />
ing evaporating temperatures, such as air conditioners, heat pumps and dehumidifiers.