2 GENERAL INFORMATION<br />

2.1 COMPRESSOR RANGES<br />

Doc. Code Emission Revision Date Page<br />

MP01E 2000-04 0 20-02 13 - 98<br />

COMPRESSORS<br />

HANDBOOK<br />

Chapter<br />

GENERAL INFORMATION<br />

Table 1 indicates the refrigerant types used in the compressors available on catalog for each series<br />

and according to the different applications.<br />

Table 1 <strong>Compressor</strong> Series - Application - Refrigerants<br />

SERIES<br />

APPLICATION<br />

LBP MBP HBP AC<br />

EM<br />

–<br />

R134a - R600a - R404A - R290 R404A - R290 R134a - R600a –<br />

NB<br />

R134a - R600a - R404A -<br />

R507<br />

R404A - R507 R22 - R134a –<br />

NE<br />

R22 - R134a - R404A - R507 -<br />

R290<br />

R404A - R507<br />

R290<br />

R22 - R134a -<br />

R600a<br />

R22 - R407C<br />

T - NT<br />

R22 - R134a - R404A - R507 - R404A - R507<br />

R290<br />

R290<br />

R22 - R134a -<br />

R22 - R407C<br />

NJ R22 - R134a - R404A - R507 R404A - R507 R22 - R134a R22 - R407C<br />

The available models in the different applications, the thermodynamic and electrical performances,<br />

the external dimensions and the approved electrical components, are listed in the General Catalog,<br />

Technical Bulletin, Electrical Components Catalog and Electronic Catalog, which<br />

complement this <strong>Handbook</strong>.<br />

2.2 APPLICATIONS<br />

Table 2 Applications<br />

TYPE DESCRIPTION<br />

(Low Back Pressure)<br />

Models at low evaporating temperatures, suitable for applications with working<br />

LBP<br />

evaporating temperatures lower than -20 °C; for instance refrigerators, freezers,<br />

frozen food cabinets, frozen food display cases, display windows, etc.<br />

(Medium Back Pressure)<br />

Models for medium evaporating temperatures, suitable for applications with work-<br />

MBP<br />

ing evaporating temperatures higher than -20 °C; such as fresh food cabinets, drink<br />

coolers, ice makers etc.<br />

(High Back Pressure)<br />

Models at high evaporating temperatures, suitable for applications with working<br />

HBP<br />

evaporating temperatures higher than -15 °C; such as fresh food cabinets, drink<br />

coolers, ice makers, dehumidifiers etc.<br />

(Air Conditioning)<br />

Models for air conditioning with R22, suitable for applications with positive work-<br />

AC<br />

ing evaporating temperatures, such as air conditioners, heat pumps and dehumidifiers.