Compressor Handbook - Embraco
Compressor Handbook - Embraco
Compressor Handbook - Embraco
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
2.9.1 <strong>Compressor</strong> Wiring Diagram - EM Series - RSIR<br />
Doc. Code Emission Revision Date Page<br />
MP01E 2000-04 0 20-02 24 - 98<br />
COMPRESSORS<br />
HANDBOOK<br />
Chapter<br />
GENERAL INFORMATION<br />
The electrical connections on the terminal board can be made with 4.76mm (3/16") male quickconnect<br />
terminations and with M 3.5 x 6 screws that are on three terminals L1-N-ground. Connection<br />
for the compressor ground is with a 4.76 mm quick-connect termination.<br />
Figure 9 RSIR Version terminal board with PTC starting device<br />
RSIR aSE010<br />
2.9.2 <strong>Compressor</strong> Wiring Diagram NB Series – RSIR-RSCR<br />
Standard version allows electrical connection with 4.76mm (3/16") male quick-connect terminations<br />
to the overload protector, PTC and grounding terminal; with M 3.5 screws on the terminal<br />
for the starting device and for the compressor ground.<br />
Figure 10 RSIR and RSCR Standard Version<br />
C<br />
3<br />
S R<br />
3 2 1<br />
21<br />
RSIR aSE020<br />
C<br />
S<br />
2<br />
RSCR (mandatory run capacitor) aSE030 RSCR (optional run capacitor) aSE040<br />
t<br />
L<br />
1<br />
3<br />
C<br />
S<br />
2<br />
2<br />
R<br />
N<br />
t<br />
L<br />
1<br />
3<br />
2<br />
R<br />
N<br />
L1<br />
L2<br />
N<br />
t<br />
t<br />
L<br />
1<br />
3<br />
C<br />
S<br />
2<br />
2<br />
R<br />
N