7.1.5 <strong>Compressor</strong> operating fields<br />

COMPRESSORS<br />

HANDBOOK<br />

Chapter<br />

RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES<br />

Within the minimum and maximum values typical for each model.<br />

In the diagrams represented on the following pages, indicated are the limits of evaporating, condensing,<br />

ambient and return gas temperatures.<br />

The compressor can operate within the limits of evaporating and condensing temperatures defined<br />

by the outlined area bordered by a continuous line, at the indicated conditions of ambient<br />

and return gas temperature.<br />

Outside these operating fields, the system operates at high pressures and high temperatures, and<br />

cause early defects in the compressor.<br />

The compressor defects caused by applications operating outside the prescribed fields will not<br />

be considered under warranty.<br />

7.1.5.1 R22 <strong>Compressor</strong>s operating field<br />

The production of R22 compressors was required for the replacement of R12 - R502 refrigerants<br />

and the choice has been obliged by the non availability at that moment of other suitable alternative<br />

gases.<br />

For low and medium temperature R22 cabinets, compressors must be selected according to the<br />

limits associated with this type of gas, that was developed for high evaporating temperatures,<br />

thus characterized by restrictive limits.<br />

7.1.5.2 R404A - R507 - R600a - R134a - R22 – R290 compressors operating field<br />

The working fields represented in this section are related to all model and series of compressors<br />

that take the indicated refrigerant.<br />

1 – LBP: R134a – R600a<br />

2 – LBP: R404A – R507 – R290<br />

3 – MBP: R404A – R507 – R290<br />

4 – HBP: R134a – R600a – R 22<br />

5 – LBP: R 22<br />

6 – AC<br />

Doc. Code Emission Revision Date Page<br />

MP01E 2000-04 0 20-02 80 - 98