3.4 DEHYDRATION<br />
Table 10 Maximum level of residual humidity<br />
3.5 PAINTING<br />
Doc. Code Emission Revision Date Page<br />
COMPRESSORS<br />
HANDBOOK<br />
Chapter<br />
COMPRESSOR SUPPLY CONDITIONS<br />
SERIES RESIDUAL MOISTURE MAXIMUM AMOUNT<br />
EM - NB - NE 60 mg H 2O<br />
T - NT 80 mg H 2 O<br />
NJ 90 mg H 2 O<br />
Black water based paint resists corrosion for 240 hours (test in humid atmosphere - ambient 43<br />
°C and relative humidity 100% - according to standard ASTM D 2247).<br />
The compressors are supplied with the tube ends and the electrical connections on the unpainted<br />
hermetic terminal.<br />
3.6 COMPRESSOR PRESSURISATION<br />
The compressor is pressurized to a pressure of about 0.2 bar with dry air (dew point lower than<br />
-40 °C); the tubes are sealed with rubber plugs to maintain this pressure.<br />
The compressors for use with hydrocarbons are supplied without pressurization.<br />
3.7 OIL CHARGE<br />
Table 11 shows the lubricant charged in the various series of compressors. The quantity is indicated<br />
in the General Catalog and Technical Bulletin. Only in an exceptional case, in accordance<br />
with the Sales Department, can the compressors be shipped without oil.<br />
In the interest of warranty, occasionally additives or substitution of the lubricant, can be made<br />
by the customer under the approval of <strong>Embraco</strong> Europe.<br />
A colored “O” stamped on the compressor cover indicates the presence and type of oil (for color<br />
and oil type see Table 11).<br />
The maximum humidity content in the oil is 40 ppm.<br />
MP01E 2000-04 0 20-02 31 - 98