<strong>Enquiry</strong> <strong>Specification</strong> <strong>for</strong> <strong>Wagon</strong> <strong>Tippler</strong> <strong>with</strong> <strong>Side</strong> <strong>Arm</strong> <strong>Charger</strong> <strong>and</strong> Associated works<br />

NRO/CON/WT/533<br />

18.0 Load side<br />

components<br />

-Filter network -Electronic over-load relay <strong>for</strong><br />

each motor (<strong>with</strong> display). -Line contactors in<br />

output side (if required). -Output reactor /<br />

terminator (if required)<br />

19.0 Terminal blocks -Separate <strong>for</strong> control <strong>and</strong> power wiring. -Power<br />

terminal blocks to <strong>with</strong>st<strong>and</strong> a minimum of 90 ºC<br />

<strong>and</strong> marked <strong>for</strong> both inputs <strong>and</strong> outputs . -<br />

Uni<strong>for</strong>m color-coding to be followed <strong>for</strong> cabling,<br />

TB, etc.<br />

20.0 By-pass<br />

Arrangement<br />

By-pass arrangement shall be provided to operate<br />

the motor in case of failure of VFD.<br />

21.0 Diode Bridge Minimum ratings of Diode cells. -PIV rating : 2.5<br />

times the peak value of line voltage -dv/dt rating<br />

: 200V/microsecond <strong>for</strong> voltage control <strong>and</strong><br />

1000V/ microsec. <strong>for</strong> inverter control. -di/dt<br />

rating : 100A / microsecond.<br />

22.0 Input / Outputs • Hardwired I/O should be provided via separate<br />

I/O cards -St<strong>and</strong>ard I/O Card • The “St<strong>and</strong>ard<br />

I/O board should consist of both digital <strong>and</strong><br />

analog I/O. It should be available in two versions;<br />

one <strong>for</strong> 115/240 VAC digital I/O <strong>and</strong> one <strong>for</strong> 24V<br />

AC/DC digital I/O. -Analog I/O • Differentially<br />

isolated ±10V (bi-polar) / 20mA analog inputs . -<br />

Digital Outputs • Relay outputs – Minimum 04<br />

nos. • Contact output ratings should be 240V AC /<br />

24V DC, Maximum 2.0 Amp<br />

23.0 Protective features AC line surge suppression network <strong>and</strong><br />

overvoltage protection . -Under voltage in supply<br />

network -Phase sequence protection <strong>and</strong><br />

monitoring -Single phase failure -Motor loss -<br />

Under voltage in DC bus -Over voltage in DC bus<br />

-Over speed protection in the event that the<br />

output frequency exceeds the maximum reference<br />

by a specified amount. -Over load -Earth fault -<br />

Instantaneous over current -Trans<strong>for</strong>mer fault ,If<br />

applicable -Cooling fan failure -Stall monitor <strong>for</strong><br />

motor alarms -Controlled shut down, when<br />

properly fused, <strong>with</strong> no component failure in the<br />

event of an output phase to phase or phase to<br />

ground short circuit <strong>and</strong> annunciation of the fault<br />

condition.<br />

24.0 Annunciations Following faults shall be annunciated in keypad of<br />

the drive / HMI . -AC line surge suppression<br />

network <strong>and</strong> overvoltage protection . -Under<br />

voltage in supply network -Phase sequence<br />

protection <strong>and</strong> monitoring -Under voltage in DC<br />

bus -Over voltage in DC bus -Over speed monitor<br />

-Over load -Earth fault<br />

EPI – New Delhi Volume-2B, Rev.0 Page 48 of 63