Samsung iPOLiS SRN-3250 User Manual - Use-IP
Samsung iPOLiS SRN-3250 User Manual - Use-IP
Samsung iPOLiS SRN-3250 User Manual - Use-IP
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Note<br />
3.1.5. Sensor<br />
You may connect an external HDD while the product is in operation. However,<br />
this may result in certain models of external HDDs not being detected. As<br />
such, it is recommended that you connect any external HDD by following the<br />
steps outlined below.<br />
1. Turn the product off.<br />
2. Connect the external HDD (also turned off) to the product with an eSATA<br />
interface cable.<br />
3. Turn on the external HDD.<br />
4. Turn on the product.<br />
The eSATA cable is not included with the product.<br />
For a list of compatible HDDs, please refer to"※ Recommended HDDs".<br />
The following are specifications and operating conditions for sensor input.<br />
Spec<br />
Power<br />
eSATA external HDD<br />
Number of Input Circuits 2<br />
Input Types N.C , N.O<br />
Supported Sensor Types Dry Contact sensors.<br />
Connection Type Attach stripped wire connections to the terminal block.<br />
DC 150V<br />
Output Current Typical DC 12mA<br />
Please refer to the diagram on the next page to connect sensor inputs. It illustrates an example<br />
of a dry contact sensor being connected to the product.<br />
23