3.2.8 Analog Output Menu<br />

The ALGOUT menu is used only if the analog output option is installed. If the analog output option is installed,<br />

configure all other indicator functions and calibrate the indicator (see Section 4.0 on page 24) before configuring<br />

the analog output. See Section 7.8 on page 42 for analog output calibration procedures.<br />

CONFIG XXXXXXX FORMAT<br />

SOURCE<br />

GROSS<br />

NET<br />

CALIBR<br />

SERIAL<br />

OFFSET ERRACT<br />

0%<br />

20%<br />

FULLSC<br />

HOLD<br />

PROGRM XXXXXXX PFORMT<br />

MIN<br />

000000<br />

number<br />

Figure 3-12. Analog Output Menu<br />

ALG OUT Menu<br />

Parameter<br />

Level 2 submenus<br />

Choices Description<br />

SOURCE GROSS<br />

NET<br />

Specifies the source tracked by the analog output.<br />

OFFSET 0%<br />

Zero offset. Selects whether the analog output supplies voltage (0–10 V) or current (4–20 mA)<br />

20% output. Select 0% for 0–10 V output; select 20% for 4–20 mA output.<br />

ERRACT FULLSC Error action. Specifies how the analog output responds to system error conditions.<br />

HOLD Possible values are:<br />

ZEROSC<br />

FULLSC Set to full value (10 V or 20 mA)<br />

HOLD: Hold current value<br />

MIN 000000<br />

ZEROSC: Set to zero value (0 V or 4 mA)<br />

Specifies the minimum weight value tracked by the analog output. Specify a weight value (in<br />

number primary units) in the range 0–999 990.<br />

MAX 010000 Specifies the maximum weight value tracked by the analog output. Specify a weight value (in<br />

number primary units) in the range 0–999 990.<br />

TWZERO — Tweak zero. Adjust the analog output zero calibration. Use a multimeter to monitor the analog<br />

output value. Press and hold or to adjust the output. Press to save the new value.<br />

TWSPAN — Tweak span. Adjust the analog output span calibration. Use a multimeter to monitor the analog<br />

output value. Press and hold or to adjust the output. Press to save the new value.<br />

Table 3-8. Analog Output Menu Parameters<br />

3.2.9 Version Menu<br />

The VERS menu is used to check the software version installed in the indicator. There are no parameters<br />

associated with the Version menu: when selected, the indicator displays the installed software version number.<br />

CONFIG FORMAT<br />

XXXXXXX<br />

CALIBR<br />

ZEROSC<br />

SERIAL<br />

PROGRM PFORMT XXXXXXX<br />

DIG IN<br />

Figure 3-13. Version Menu<br />

XXXXXXX ALGOUT XXXXXXX VERS<br />

MAX TWZERO<br />

10000<br />

number<br />

DIG IN<br />

ALGOUT XXXXXXX XXXXXXX VERS<br />

Software<br />

version<br />

TWSPAN<br />

Configuration 23