IQ plus® 355 - Cisco-Eagle, Inc.
IQ plus® 355 - Cisco-Eagle, Inc.
IQ plus® 355 - Cisco-Eagle, Inc.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
3.2.8 Analog Output Menu<br />
The ALGOUT menu is used only if the analog output option is installed. If the analog output option is installed,<br />
configure all other indicator functions and calibrate the indicator (see Section 4.0 on page 24) before configuring<br />
the analog output. See Section 7.8 on page 42 for analog output calibration procedures.<br />
CONFIG XXXXXXX FORMAT<br />
SOURCE<br />
GROSS<br />
NET<br />
CALIBR<br />
SERIAL<br />
OFFSET ERRACT<br />
0%<br />
20%<br />
FULLSC<br />
HOLD<br />
PROGRM XXXXXXX PFORMT<br />
MIN<br />
000000<br />
number<br />
Figure 3-12. Analog Output Menu<br />
ALG OUT Menu<br />
Parameter<br />
Level 2 submenus<br />
Choices Description<br />
SOURCE GROSS<br />
NET<br />
Specifies the source tracked by the analog output.<br />
OFFSET 0%<br />
Zero offset. Selects whether the analog output supplies voltage (0–10 V) or current (4–20 mA)<br />
20% output. Select 0% for 0–10 V output; select 20% for 4–20 mA output.<br />
ERRACT FULLSC Error action. Specifies how the analog output responds to system error conditions.<br />
HOLD Possible values are:<br />
ZEROSC<br />
FULLSC Set to full value (10 V or 20 mA)<br />
HOLD: Hold current value<br />
MIN 000000<br />
ZEROSC: Set to zero value (0 V or 4 mA)<br />
Specifies the minimum weight value tracked by the analog output. Specify a weight value (in<br />
number primary units) in the range 0–999 990.<br />
MAX 010000 Specifies the maximum weight value tracked by the analog output. Specify a weight value (in<br />
number primary units) in the range 0–999 990.<br />
TWZERO — Tweak zero. Adjust the analog output zero calibration. Use a multimeter to monitor the analog<br />
output value. Press and hold or to adjust the output. Press to save the new value.<br />
TWSPAN — Tweak span. Adjust the analog output span calibration. Use a multimeter to monitor the analog<br />
output value. Press and hold or to adjust the output. Press to save the new value.<br />
Table 3-8. Analog Output Menu Parameters<br />
3.2.9 Version Menu<br />
The VERS menu is used to check the software version installed in the indicator. There are no parameters<br />
associated with the Version menu: when selected, the indicator displays the installed software version number.<br />
CONFIG FORMAT<br />
XXXXXXX<br />
CALIBR<br />
ZEROSC<br />
SERIAL<br />
PROGRM PFORMT XXXXXXX<br />
DIG IN<br />
Figure 3-13. Version Menu<br />
XXXXXXX ALGOUT XXXXXXX VERS<br />
MAX TWZERO<br />
10000<br />
number<br />
DIG IN<br />
ALGOUT XXXXXXX XXXXXXX VERS<br />
Software<br />
version<br />
TWSPAN<br />
Configuration 23