GENERAL/OVERVIEW<br />

General<br />

Sine wave outputs: The sine wave signals are available as voltage<br />

signals. They can be further processed<br />

and can be multiplied by a factor of usually<br />

10, 20, 50, 100, 400, 500, 1000 res. binary<br />

factors (512, 1024). Due to the interpolation<br />

of the two signals, which are 90° out of<br />

phase, a very high resolution can be achieved.<br />

This makes these kind of signals specially<br />

useful for applications where very high<br />

resolutions are required. Further they are<br />

very suitable for digital drives with a very<br />

slow and precise movement, e.g. for grinding<br />

machines or lifts and elevators.<br />

Output circuit and recommended<br />

input circuit for sine wave voltage<br />

signals:<br />

R a = 10 Ω Z = 120 Ω<br />

C 1 = 150 pF U 1 = U 0<br />

C 2 = 10 pF<br />

R 1 = 10 kΩ<br />

R 2 = 33 kΩ<br />

U 0 = 2,5 V ±0,5 V OPV: z.B. MC33074<br />

Cable length: Depending on the output circuit and the electrical noise the following cable lengths are recommended:<br />

Output circuit max. cable length Encoder connected<br />

to e.g.<br />

Push-pull without inverted<br />

signals 100 m counter/PLC<br />

Push-pull with inverted signals 250 m PLC/IPC 1 )<br />

RS 422 with inverted signals up to 1000 m PLC/IPC 1 )<br />

(> 50 m depending<br />

on frequency)<br />

Voltage sinus with inverted<br />

signals 50 m PLC/IPC 1 )<br />

1)IPC = industrial PC<br />

Annotations:<br />

Depending on the application the recommended cable length can be shorter, especially in<br />

areas with strong electrical noise.<br />

Always use shielded cables<br />

The core diameter of the signal cores should be ∅ 0,14 mm 2<br />

The core diameter of the voltage supply cores should be large enough depending on the<br />

cable length, that the voltage supply of the encoder is high enough and the signals do not<br />

go below the minimum levels!<br />

We strictly recommend the use of the cable types written down in the accessories.<br />

Meyer <strong>Industrie</strong>-<strong>Electronic</strong> GmbH – MEYLE<br />

Carl-Bosch-Straße 8<br />

49525 Lengerich/Germany<br />

Tel.: +49 54 81-93 85-0<br />

Fax: +49 54 81-93 85-12<br />

Shaft turning clockwise, top view of shaft<br />

0-pulse is generated once per turn<br />

encoder recommended<br />

input circuit<br />

Internet: www.meyle.de<br />

E-Mail: sales@meyle.de<br />

1 V /<br />

1 V /<br />

1 V /

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!