<strong>INCREMENTAL</strong> <strong>ENCODER</strong> <strong>MyInc</strong><br />

Mounting advice:<br />

1<br />

Cyl.-pin to DIN 7 ø 4 mm<br />

ORDERING CODE<br />

BINH37<br />

Flange<br />

1 = Hollow shaft<br />

with short<br />

torque stop<br />

2 = Hollow shaft<br />

with long<br />

torque stop<br />

5 = Hollow shaft<br />

with stator<br />

coupling<br />

1) Do not connect the encoder and drive<br />

rigidly to one another at the shaft and<br />

flange!<br />

2) To mount a hollow shaft encoder, we<br />

recommend the use of a pin and with<br />

torque stop slot or a stator coupling.<br />

Meyer <strong>Industrie</strong>-<strong>Electronic</strong> GmbH – MEYLE<br />

Carl-Bosch-Straße 8<br />

49525 Lengerich/Germany<br />

Tel.: +49 54 81-93 85-0<br />

Fax: +49 54 81-93 85-12<br />

BINH37<br />

3) When mounting the encoder ensure<br />

that Lmin. is greater than the axial play<br />

of the drive.<br />

When using the long torque stop, a<br />

greater axial play is possible.<br />

Max. permissible drive shaft impact:<br />

(measuring error ≤ ± 0,5 bit and 4 times evaluate in the sequential electronic).<br />

Shaft Ø<br />

Mounting with stator coupling Mounting with<br />

torque support<br />

Pulses: Permissible axial Permissible radial Permissible radial<br />

impact impact impact<br />

up to 1024: ±0.4 mm ±0.09 mm ±0.075 mm<br />

1 = Ø 4 mm<br />

2 = Ø 5 mm<br />

3 = Ø 6 mm<br />

4 = Ø 1/4“<br />

6 = Ø 8 mm<br />

Output circuit and Supply<br />

voltage<br />

A2 = RS 422: 5 V DC ±5<br />

%<br />

A5 = Push-pull (with<br />

inverted signals)<br />

5 ... 30 V DC<br />

Connection<br />

3A = Cable* radial<br />

(1 m PVC-cable)<br />

3R = Cable* radial<br />

(2 m PVC-cable)<br />

* “Tube Tech ® ” cable outlet guarantees 10 x higher strain relief than<br />

traditional cabling methods plus higher IP-Protection.<br />

Other cable lengths available on request.<br />

Internet: www.meyle.de<br />

E-Mail: sales@meyle.de<br />

Resolution<br />