Register user_config Details<br />

Register (pl353) ecc_status_1<br />

Register ecc_status_1 Details<br />

Appendix B: Register Details<br />

Description The user_config<br />

is write-only and controls the status of the user_config[7:0] signals. You can write to<br />

this register in all operating states.<br />

Field Name Bits Type Reset Value Description<br />

user_config<br />

(MASK)<br />

Name ecc_status_1<br />

Software Name IF1_ECC<br />

Relative Address 0x00000400<br />

Absolute Address 0xE000E400<br />

Width 30 bits<br />

Access Type ro<br />

Reset Value 0x00000000<br />

Description ECC status and clear<br />

7:0 wo x This value sets the state of the user_config[7:0]<br />

outputs.<br />

The ecc_status<br />

is read-only and contains status information for the ECC. Although this is a read-only register, the bottom<br />

five bits can be written to clear the corresponding interrupts.To clear the interrupt, you must write a 1 to<br />

the appropriate bit.<br />

<strong>Zynq</strong>‐<strong>7000</strong> EPP Technical Reference Manual www.xilinx.com 1559<br />

UG585 (v1.2) August 8, 2012