01.06.2013 Views

Print MSDS - Miller Electric Company Publications

Print MSDS - Miller Electric Company Publications

Print MSDS - Miller Electric Company Publications

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MATERIAL SAFETY DATA SHEET<br />

DiversiTech Corporation<br />

6650 Sugarloaf Parkway<br />

Duluth, GA 30097<br />

Regular Clear PVC Solvent Cement<br />

SECTION 14. TRANSPORTATION INFORMATION<br />

DOT Less than 1 Liter (0.3 gal) Greater than 1 Liter (0.3 gal)<br />

Proper Shipping Name: Consumer Commodity Adhesives<br />

Hazard Class/Packing Group: ORM-D 3 PGII<br />

UN/NA Number: None UN1133<br />

Hazard Labels: None Flammable Liquid<br />

IMDG Less than 1 Liter (0.3 gal) Greater than 1 Liter (0.3 gal)<br />

Proper Shipping Name: Adhesives Adhesives<br />

Hazard Class/Packing Group: 3, II 3, II<br />

UN/NA Number: UN1133 UN1133<br />

Hazard Labels: None (Limited Quantities Class 3 (Flammable Liquid)<br />

are excepted from labeling)<br />

RCRA Hazardous Waste Number: U002, U057, U159, U213<br />

EPA Hazardous Waste ID Number: D001, D035, F005<br />

EPA Hazard Waste Class: Ignitable Waste. Toxic Waste (Methyl Ethyl Ketone content)<br />

SECTION 15. REGULATIONS<br />

Hazard Category for Section 311/312: Acute Health, Chronic Health, Flammable<br />

Section 302 Extremely Hazardous Substances (TPQ): This product does not contain chemicals regulated under SARA Section 302.<br />

Section 313 Toxic Chemicals: This product contains the following chemicals subject to SARA Title III Section 313 Reporting requirements:<br />

Chemical CAS # %<br />

Methyl Ethyl Ketone 78-93-3 45-60%<br />

CERCLA 103 Reportable Quantity: Spills of this product over the RQ (reportable quantity) must be reported to the National Response Center. The RQ for<br />

the product, based on the RQ for Tetrahydrofuran (40% maximum) of 1,000 lbs, is 2,500 lbs. Many states have more stringent release reporting requirements.<br />

Report spills required under federal, state and local regulations.<br />

California Proposition 65: This product contains trace amounts of chemicals known to the State of California to cause cancer. Under normal use conditions,<br />

exposures to these chemicals at levels above the State of California "No Significant Risk Level" (NSRL) are unlikely. Oatey strongly encourages the use of<br />

proper personal protective equipment (PPE) and ventilation guidelines noted in Section 9 to minimize exposure to these chemicals.<br />

TSCA Inventory: All of the components of this product are listed on the TSCA inventory.<br />

SECTION 16. MANUFACTURED BY<br />

Diversitech<br />

6650 Sugarloaf Parkway, Suite 100<br />

Duluth, GA 30097<br />

Phone 1+678.542.3600<br />

EMERGENCY Phone No. 1 800-255-3924 Chem-Tel (Chemical Emergencies Only)<br />

SECTION 17. REFERENCE NUMBER AND DATE OF ISSUE<br />

<strong>MSDS</strong> Safety Data Sheet: 5-14, 5-12, 5-10, 5-32 Issued 03/30/2009<br />

This information is, to the best of our knowledge and belief, accurate and reliable as of the date completed. However no representation, warranty or guarantee is made as to its<br />

accuracy, reliability or completeness. It is the user’s responsibility to satisfy himself as to the completeness and suitability of such information for his own particular use. We do not<br />

accept liability for any loss or damage that may occur from the use of this information, nor do we offer any warranty against patent infringement.<br />

Page 4 of 4<br />

Chemical Emergency: P 800-255-3924<br />

P 678.542.3600<br />

F 678.542.3700

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!