Sleeve Bearing with Hydrostatic Jacking<br />

Designed with Two Lubrication Pockets<br />

for applications with high start-up load, frequent operation at low speed and very<br />

long rundown periods to avoid wearing on the bearing shell<br />

The high pressure pumps for hydrostatic lifting units are constant volume systems, i.e. they<br />

supply a defined oil throughput. The maximum load carrying capacity of the system is<br />

usually limited to 200 bar.<br />

The maximum pump pressure occurs during the starting process, due to the oil wedge<br />

being narrow when the bearing is still at rest. The beginning of the shaft lifting thus involves<br />

a remarkable pressure surge. As soon as the oil wedge gets wider as the shaft is further<br />

lifted, the pressure decreases depending on the bearing geometry and the oil throughput,<br />

since the effectively load carrying surface is increased.<br />

The constant pump pressure for holding up the shaft should be adjusted to 100 bar.<br />

Seite 84<br />

© <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />

a Siemens Company