Axial innen engl - TLT Turbo GmbH
Axial innen engl - TLT Turbo GmbH
Axial innen engl - TLT Turbo GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Ventilation<br />
<strong>Axial</strong> Flow Fans<br />
▲ AXO Series - without Guide Vanes<br />
▲ AXN Series - with Outlet Guide Vanes<br />
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong>
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
<strong>TLT</strong> standard fan production plant at Bad Hersfeld<br />
Our Bad Hersfeld facility has a history<br />
going back to 1874, when Benno<br />
Schilde and August Büttner founded<br />
their factories here.<br />
The “exhausters” traditionally made<br />
of cast iron could be built much lighter<br />
and cheaper through the use of steel<br />
sheet.<br />
At Büttner the focus was initially on<br />
blowers for tubular boilers and dryers,<br />
then shifted to heavy-duty industrial<br />
fans as required specifically in power<br />
plant de-dusting applications. Schilde,<br />
meanwhile, stepped up its research<br />
and development of light-duty<br />
ventilating fans and medium-duty industrial<br />
blowers. Numerous patents<br />
and registered designs testify to a<br />
steady flow of engineering breakthroughs.<br />
With the erection of its series<br />
production facility at Bad Hersfeld,<br />
dedicated mainly to the cost-effective<br />
production of roof fans, the<br />
Babcock-BSH Group gained a leading<br />
market position both in Germany<br />
and abroad. The <strong>Turbo</strong>-Lufttechnik<br />
<strong>GmbH</strong> (<strong>TLT</strong>) – Bad Hersfeld site - was<br />
newly established in June 1995, now<br />
integrating Babcock-BSH’s Air and<br />
Thermal Engineering division.<br />
The “<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong>”, newly established<br />
in March 2003 as a company<br />
AXIAL FLOW FANS<br />
in their own rights, belongs to AG<br />
Kühnle, Kopp & Kausch, Frankenthal.<br />
<strong>TLT</strong> now is one of the world’s leading<br />
fan manufacturers and our competence<br />
is expressed in mature and<br />
very economical products. Our two<br />
R&D centres at Zweibrücken and Bad<br />
Hersfeld guarantee a continuing process<br />
of always adapting all <strong>TLT</strong> products<br />
to the latest demands of the<br />
market.<br />
002
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Our broad range of axial flow fans,<br />
covering 21 impeller diameters<br />
from 250 to 2500mm, offers an optimal<br />
choice.<br />
In addition to the fans documented in<br />
this catalogue we supply the following<br />
axial fan series:<br />
● axial smoke exhaust fans for<br />
use at 200°C / 300°C / 400°C or<br />
600°C (120 minutes)<br />
● two-stage axial fans (in series)<br />
for use in closed car parks and<br />
for elevated pressure ranges,<br />
also as smoke exhaust fans for<br />
200°C / 300°C or 600°C /120 minutes<br />
operation.<br />
All our fan series are tested to EN<br />
12101 - Part 3 specifications by the<br />
Technical University of Munich and<br />
hold a General Construction Supervision<br />
Approval issued by the German<br />
Institute of Construction Engineering<br />
(DIBt), Berlin as well as<br />
CE-certificates.<br />
Please request our special catalogues<br />
“Smoke Exhaust Fans“ or “Two-<br />
Stage <strong>Axial</strong> Flow Fans“<br />
AXIAL FLOW FANS<br />
TABLE OF CONTENTS<br />
Types - Overview<br />
Technical description<br />
Main dimensions<br />
Diffusers<br />
Round silencers<br />
Acoustic insulation<br />
Acoustic data - AXO/AXN<br />
Volume flow measuring system VME<br />
Electrical system / circuit diagrams<br />
Performance diagrams for pre-selection<br />
Measuring configuration for axial flow fans<br />
Technical notes<br />
Installation notes<br />
Selection examples<br />
Technical lists - AXO series<br />
Characteristic curves - AXO series<br />
Tender specifications<br />
Technical lists - AXN series<br />
Characteristic curves - AXN series (direct-driven)<br />
Tender specifications<br />
Characteristic curves - AXN series (belt-driven)<br />
Tender specifications<br />
003<br />
Standard axial-flow fan<br />
in direct-drive configuration<br />
with accessories,<br />
e.g. wire guard,<br />
bellmouth inlet, extension<br />
casing and mounting<br />
feet<br />
004 - 005<br />
006<br />
007 - 013<br />
014<br />
016<br />
017 - 019<br />
020 - 021<br />
022 - 026<br />
027 - 030<br />
031 - 033<br />
034<br />
035<br />
036 - 037<br />
038 - 039<br />
042 - 043<br />
044 - 078<br />
079 - 080<br />
Wall-mounting axial flow fans - WAXO 081 - 082<br />
083 - 088<br />
089 - 131<br />
132 - 135<br />
Wall-mounting axial flow fans - WAXN 12/56 136 - 137<br />
139 - 155<br />
156 - 159<br />
Application examples/References 163
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
<strong>Axial</strong> flow fan<br />
standard direct drive model<br />
AXO type = without guide vanes<br />
Airflow direction D (motor in outlet)<br />
Impeller on motor shaft end.<br />
Fan casing with drilled flanges as per<br />
DIN 24154 – Series 3.<br />
Extension casing optionally<br />
available.<br />
Max. operating temperature<br />
according to motor type<br />
(60° C with standard motor).<br />
<strong>Axial</strong> flow fan<br />
standard direct drive model<br />
AXO type = without guide vanes<br />
Airflow direction S (motor in inlet)<br />
Impeller on motor shaft end.<br />
Fan casing with drilled flanges as per<br />
DIN 24154 – Series 3.<br />
Extension casing optionally<br />
available.<br />
Max. operating temperature according<br />
to motor type<br />
(60° C with standard motor).<br />
<strong>Axial</strong> flow fan<br />
standard direct drive model<br />
AXN type = with outlet guide vanes<br />
Airflow direction D (motor in outlet)<br />
Impeller on motor shaft end.<br />
Fan casing with drilled flanges as per<br />
DIN 24154 – Series 3.<br />
Extension casing optionally available.<br />
Max. operating temperature<br />
according to motor type<br />
(60° C with standard motor).<br />
Please ask for our special<br />
catalogue for 2 stage axial<br />
fans (in series), currently<br />
available in German language<br />
only or see our catalogue<br />
“Smoke extraction“.<br />
AXIAL FLOW FANS<br />
TYPES - OVERVIEW<br />
M-D type<br />
M-S type<br />
M-D type<br />
004
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
<strong>Axial</strong> flow fan<br />
direct drive model<br />
Swing-out type<br />
Airflow direction D (motor in outlet)<br />
Rugged sheet steel design.<br />
The impeller, motor and guide vane<br />
installation can be jointly swung out<br />
for inspection.<br />
Fan casing with drilled flanges as per<br />
DIN 24154 – Series 4.<br />
Max. operating temperature according<br />
to motor type<br />
(60° C with standard motor).<br />
<strong>Axial</strong> flow fan<br />
belt drive model<br />
Airflow direction D (outlet over bearing)<br />
The belt guard housing, doubling as<br />
motor support, is mounted on the<br />
casing. The impeller is supported in<br />
a maintenance-free double flange<br />
bearing having a rated service life of<br />
approx. 20,000 operating hrs.<br />
Max. operating temperature: 70° C.<br />
With outlet guide vanes.<br />
Fan casing with drilled flanges as per<br />
DIN 24154 – Series 3.<br />
<strong>Axial</strong> flow fan<br />
belt drive model<br />
Airflow direction D (outlet over bearing)<br />
Casing with tensioning device and<br />
belt guard on a common baseframe.<br />
The impeller is supported in antifriction<br />
bearings with grease valve and<br />
re-lubricating feature. Rated service<br />
life: approx. 50,000 operating hours.<br />
Max. operating temperature: 70° C.<br />
The belt tensioning installation with<br />
motor and belt drive are fitted in specially<br />
developed mountings. Outlet<br />
guide vanes enhance the fan output<br />
characteristics.<br />
Fan casing with drilled flanges as per<br />
DIN 24154 – Series 3.<br />
<strong>Axial</strong> flow fan - wall mounting type<br />
WAXO/WAXN series<br />
for installation into outside walls<br />
System consisting of:<br />
- axial fan direct drive model, impeller<br />
with shaft, casing with drilled flanges<br />
as per DIN 24154 series 3.<br />
Max. operating temperatures as per<br />
motor version. In case of normal<br />
motors: 60°C.<br />
- bellmouth with wire guard wall-mounting<br />
plate (drilled)<br />
- louvre damper<br />
AXIAL FLOW FANS<br />
TYPES - OVERVIEW<br />
M-A type<br />
R1 type<br />
R2 type<br />
005
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
AXN SERIES with outlet<br />
Guide Vanes<br />
Technical Description<br />
High output and broad operationg<br />
poing adaptability are key features of<br />
all fans of this series.<br />
■ 21 available design sizes with casing<br />
diameters from 250 to 2500<br />
mm<br />
■ Two basic designs for direct drive<br />
(M) or belt drive (R).<br />
■ From optimum pressure coefficiets<br />
this series is equipped with outlet<br />
guide vanes.<br />
■ impeller blades are steplessly<br />
pitch-adjustable without having to<br />
remove the impeller from the unit.<br />
Post-installation adjustments to<br />
specific operating points within the<br />
motor output range can thus be easily<br />
made.<br />
■ Impellers can be supplied with 12,<br />
9, 8, 6 or 4 blades (important particularly<br />
for direct-driven fans).<br />
■ The impeller material is cast solumin,<br />
with the exception of the clamping<br />
strap which consists fo AlMg<br />
3F-2. A high weather and seawater<br />
resistance is thus ensured.<br />
■ On R1 and R2 (belt driven) types,<br />
an additional operatiin point matching<br />
feature is available via the<br />
“stepless“ impeller rpm adjustment<br />
which can be achieved by changing<br />
the belt transmission ratio.<br />
■ High pressure coefficients permit<br />
low tip speeds for minimum operating<br />
noise.<br />
■ Efficiencies up to 82%<br />
■ Tip speeds up to 85 m/s<br />
■ Direct-driven fans are normally<br />
supplied as airflow direction “D“<br />
(outlet over motor) designs. In special<br />
cases, airflow direction “S“<br />
Unless special precautions are<br />
taken, these axial-flow fans are not<br />
suitable for outdoor installation (enquiries<br />
to be directed to our headquarters).<br />
AXIAL FLOW FANS<br />
AXO SERIES - WITHOUT GUIDE VANES<br />
AXN SERIES - WITH OUTLET GUIDE VANES<br />
TECHNICAL DESCRIPTION<br />
(inlet over motor) types are available.<br />
The dimensioning for airflow direction<br />
“S“ axial-flow fans is done<br />
by our field representatives or at<br />
our company headquarters.<br />
■ Their compact design allows these<br />
fans to be installed even where<br />
space is at a premium.<br />
■ All fans are powered by IEC standard<br />
motors. Motors with thermocouples<br />
or thermistor sensors are<br />
available upon request.<br />
■ Standard units are rated for up to<br />
80°C, depending on motor insulation<br />
class.<br />
■ Casings up to size 1250 are made<br />
of deep-drawing grade sheet steel<br />
with pressed flanges.<br />
■ Fans up to size 1205 are surface-finished<br />
with a RAL 7030 (pebblegrey)<br />
polyester powder coating. As<br />
of size 1400, fans are supplied finispainted<br />
in RAL 7030 (pebble-grey)<br />
colour.<br />
AXO Series<br />
without Guid Vanes<br />
Technical Description<br />
006<br />
■ 7 design size with casing diameters<br />
from 315 to 1120 mm.<br />
■ Available as type “M“ for direct<br />
drive.<br />
■ Not designed for subsequent impeller<br />
blade adjustment.<br />
■ Built with 5, 8, 9 or 12 blades, depending<br />
on specified output<br />
■ Aluminium impeller hub with plastic<br />
blades.<br />
■ Up to 68% efficiency.<br />
■ Tip speeds up to 82 m/s<br />
■ Direct-driven fans are normally<br />
supplied as airflow direction “D“<br />
(outlet over motor) designs. In special<br />
cases, airflow direction “S“<br />
(inlet over motor) types are available.<br />
The demensionins ofor airflow<br />
directions “S“ axial-flow fans is<br />
done by our field representatives or<br />
at company headquarters.<br />
■ Their compact design allows these<br />
fans to be installed even where<br />
space is at a premium.<br />
■ All fans are powered by IEC standard<br />
motors. Motors with thermocouples<br />
or thermisotor sensors are<br />
available upon request.<br />
■ Standard units are rated for up to<br />
60°C, depending on motor insulation<br />
class<br />
■ Casings up to size 1120 are made<br />
of deep-drawing grade sheet steel<br />
with pressed flanges.<br />
■ Units are surface-finished with a<br />
RAL 7030 (pebble-grey) polyester<br />
powder coatching.<br />
For planning and installation, please<br />
also refer to our Installation,<br />
Operating and Maintenance<br />
Instructions (MBW).
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Ø k<br />
Ø k<br />
� For vibration-damped installation an<br />
extension casing will be required with<br />
certain fan sizes.<br />
L<br />
M max.<br />
� Motorsize<br />
Size Type B 3<br />
L<br />
AXIAL FLOW FANS AXO SERIES<br />
DIRECT DRIVE<br />
MAIN DIMENSIONS<br />
TYPE M-D and M-S<br />
Type M-D �<br />
(airflow direction:<br />
outlet over motor)<br />
� Sizes 400 - 1120 are available for<br />
„anticlockwise“ rotation (viewed<br />
in airflow direction) only.<br />
� Type M-S<br />
(airflow direction:<br />
intake over motor)<br />
by request<br />
007<br />
Important! This fan series is available only with the motor<br />
outputs stated in our price lists.<br />
Dimensions in mm<br />
Dimensional and design<br />
changes reserved.<br />
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).<br />
z x d<br />
Design with<br />
duct extension<br />
or long duct<br />
z x d<br />
Ø i.d. Ø k Ø D z x d L<br />
�<br />
ø i.d.<br />
ØD<br />
�<br />
ø i.d.<br />
ØD<br />
M<br />
max.<br />
Weight<br />
[kg]<br />
without Motor<br />
315 71 - 80 320 356 386 8 x 9,5 150 265 6,0<br />
400<br />
71 - 90<br />
100<br />
401 438 468 12 x 9,5<br />
188<br />
376<br />
348<br />
390<br />
11<br />
16<br />
500<br />
80 - 100<br />
90 - 132<br />
504 541 571 12 x 9,5<br />
225<br />
450<br />
570<br />
451<br />
16<br />
22<br />
630<br />
90 - 112<br />
132<br />
634 674 712 16 x 11,5<br />
286<br />
572<br />
595<br />
575<br />
30<br />
39<br />
800<br />
100 - 132<br />
160<br />
797 837 875 24 x 11,5<br />
350<br />
700<br />
760<br />
810<br />
50<br />
70<br />
1000<br />
132 - 180<br />
200<br />
1003 1043 1081 24 x 11,5<br />
415<br />
830<br />
730<br />
770<br />
85<br />
105<br />
1120 132 - 200 1124 1174 1214 24 x 11,5 450 825 110<br />
1250<br />
160 - 225<br />
250 - 280<br />
1261 1311 1351 24 x 11,5<br />
500<br />
1000<br />
1400<br />
180 - 225<br />
250 - 315<br />
1415 1465 1545 24 x 11,5<br />
560<br />
1120<br />
1600<br />
180 - 225<br />
250 - 315<br />
1587 1637 1717 32 x 11,5<br />
560<br />
1120<br />
by request
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Type M-D<br />
(Airflow direction:<br />
motor in outlet)<br />
Size 1)<br />
AXIAL FLOW FANS AXN SERIES<br />
DIRECT DRIVE<br />
MAIN DIMENSIONS<br />
TYPE M-D<br />
Ø<br />
Weight<br />
i. d. Ø k Ø D z x d2) L X Mmax. [kg]<br />
without motor<br />
250 254 286 310 6x 7,0 125 62 275 4,0<br />
280 286 322 352 8x 9,5 135 64 310 5,0<br />
315 320 356 386 8x 9,5 150 71 320 6,5<br />
355 359 395 425 8x 9,5 165 77 370 8,0<br />
400 401 438 468 12x 9,5 188 88 430 12<br />
450 450 487 517 12x 9,5 200 88 440 14<br />
500 504 541 571 12x 9,5 225 100 540 18<br />
560 565 605 643 16x11,5 242 100 560 26<br />
630 634 674 712 16x11,5 286 128 570 33<br />
710 711 751 789 16x11,5 305 128 700 45<br />
800 797 837 875 24x11,5 350 150 780 56<br />
900 894 934 972 24x11,5 373 149 930 74<br />
1000 1003 1043 1081 24x11,5 415 165 960 93<br />
1120 1124 1174 1214 24x11,5 450 170 1200 120<br />
1250 1261 1311 1351 24x11,5 500 185 1230 145<br />
1) For vibration-damped installation<br />
an extension casing<br />
may be required with fans up<br />
to size 1000.<br />
M max.<br />
1400 1415 1465 1545 24x11,5<br />
1600 1587 1637 1717 32x11,5<br />
1800 1780 1830 1910 32x11,5<br />
2000 1997 2047 2167 32x11,5<br />
900 547 1020 460<br />
1120 767 1350 495<br />
900 500 1070 570<br />
1120 725 1390 610<br />
1120 675 1340 710<br />
1250 805 1670 755<br />
1120 655 1360 900<br />
1400 935 1700 960<br />
2) Connecting dimensions<br />
according to DIN<br />
24 145 – Series 3<br />
3) Special flanges may<br />
be needed with certain<br />
sizes.<br />
For vibration-damped<br />
installation two Extension<br />
casings should be<br />
provided.<br />
Motor Size - Type<br />
Flange dia. 3) - Shaft dia.<br />
008<br />
Important! This fan series is available only with the motor<br />
outputs stated in our price lists.<br />
63 - B 14 71 - B 14<br />
120 - 11 120 - 14<br />
63 - B 14 71 - B 14 80 - B 14<br />
120 - 11 120 - 14 120 - 19<br />
71 - B 5 80 - B 14<br />
160 - 14 160 - 19<br />
71 - B 5 80 - B 14 90 - B 14<br />
160 - 14 160 - 19 160 - 24<br />
71 - B 5 80 - B 5 90 - B 5 100 - B 14 112 - B 14<br />
160 - 14 200 - 19 200 - 24 200 - 28 200 - 28<br />
71 - B 5 80 - B 5 90 - B 5 100 - B 14 112 - B 14<br />
160 - 14 200 - 19 200 - 24 200 - 28 200 - 28<br />
71 - B 5 80 - B 5 90 - B 5 100 - B 5 112 - B 5 132 - B 5<br />
160 - 14 200 - 19 200 - 24 250 - 28 250 - 28 250 - 38<br />
71 - B 5 80 - B 5 90 - B 5 100 - B 5 112 - B 5 132 - B 5<br />
160 - 14 200 - 19 200 - 24 250 - 28 250 - 28 250 - 38<br />
71 - B 5 80 - B 5 90 - B 5 100 - B 5 112 - B 5 132 - B 5<br />
160 - 14 200 - 19 200 - 24 250 - 28 250 - 28 250 - 38<br />
80 - B 5 90 - B 5 100 - B 5 112 - B 5 132 - B 5 160 - B 5<br />
200 - 19 200 - 24 250 - 28 250 - 28 250 - 38 350 - 42<br />
90 - B 5 100 - B 5 112 - B 5 132 - B 5 160 - B 5 180 - B 5<br />
200 - 24 250 - 28 250 - 28 250 - 38 350 - 42 350 - 48<br />
100 - B 5 112 - B 5 132 - B 5 160 - B 5 180 - B 5<br />
250 - 28 250 - 28 250 - 38 350 - 42 350 - 48<br />
200 - B 5 225 - B 5<br />
350 - 55 350 - 60<br />
100 - B 5 112 - B 5 132 - B 5 160 - B 5 180 - B 5<br />
250 - 28 250 - 28 250 - 38 350 - 42 350 - 48<br />
200 - B 5 225 - B 5<br />
450 - 55 450 - 60<br />
160 - B 5 180 - B 5 200 - B 5 225 - B 5 250 - B 5 280 - B 5<br />
350 - 42 350 - 48 400 - 55 450 - 60 550 - 65 550 - 75<br />
160 - B 5 180 - B 5 200 - B 5 225 - B 5 250 - B 5 280 - B 5<br />
350 - 42 350 - 48 400 - 55 450 - 60 550 - 65 550 - 75<br />
160 - B 5 180 - B 5<br />
350 - 42 350 - 48<br />
200 - B 5 225 - B 5 250 - B 5 280 75 315 80<br />
400 - 55 450 - 60 550 - 65 B3/V1/V3 B3/V1/V3<br />
200 - B 5 225 - B 5<br />
400 - 55 450 - 60<br />
250 - B 5 280 75 315 80<br />
550 - 65 B3/V1/V3 B3/V1/V3<br />
225 - B 5 250 - B 5 280 75<br />
450 - 60 550 - 65 B3/V1/V3<br />
315 80 355 90<br />
B3/V1/V3 B3/V1/V3<br />
225 60 250 65 280 75<br />
B3/V1/V3 B3/V1/V3 B3/V1/V3<br />
315 80 355 90<br />
B3/V1/V3 B3/V1/V3<br />
Dimensions in mm<br />
Dimensional and design<br />
changes reserved.<br />
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).<br />
i.d.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Size<br />
Ø<br />
i.d. Ø k Ø D z x Ø d 1) L a b<br />
AXIAL FLOW FANS AXN SERIES<br />
DIRECT DRIVE<br />
MAIN DIMENSIONS<br />
TYPE M-A<br />
Weight<br />
[kg]<br />
without motor<br />
400 401 448 484 12x11,5 600 100 400 80<br />
450 450 497 533 12x11,5 700 125 450 93<br />
500 504 551 587 12x11,5 700 125 450 114<br />
560 565 629 669 16x14 800 125 550 147<br />
630 634 698 738 16x14 900 150 600 188<br />
710 711 775 815 16x14 1000 150 700 245<br />
800 797 861 901 24x14 1150 150 850 333<br />
900 894 958 998 24x14 1200 150 900 400<br />
1000 1003 1067 1107 24x14 1300 200 900 490<br />
1120 1124 1200 1254 32x18 1400 200 1000 706<br />
1250 1261 1337 1397 32x18 1500 250 1000 856<br />
1400 1415 1491 1545 32x18 1600 250 1100 1055<br />
1) Connecting dimensions<br />
according to DIN 24 145<br />
Series 4<br />
2) Special flanges may be<br />
needed with certain sizes.<br />
Available with airflow<br />
direction D only.<br />
i.d.<br />
* For vertical installation use<br />
motor types V1 or V3<br />
(flange diameter data<br />
available on request).<br />
Motor size - Type<br />
Flange dia. 2) - Shaft dia.<br />
009<br />
71 - B 5 80 - B 5 90 - B 5<br />
160 - 14 200 - 19 200 - 24<br />
71 - B 5 80 - B 5 90 - B 5<br />
160 - 14 200 - 19 200 - 24<br />
71 - B 5 80 - B 5 90 - B 5<br />
160 - 14 200 - 19 200 - 24<br />
71 - B 5 80 - B 5 90 - B 5 100 - B 5 112 - B 5<br />
160 - 14 200 - 19 200 - 24 250 - 28 250 - 28<br />
71 - B 5 80 - B 5 90 - B 5 100 - B 5 112 - B 5 132 - B 5<br />
160 - 14 200 - 19 200 - 24 250 - 28 250 - 28 250 - 38<br />
80 - B 5 90 - B 5 100 - B 5 112 - B 5 132 - B 5 160 - B 5<br />
200 - 19 200 - 24 250 - 28 250 - 28 250 - 38 350 - 42<br />
90 - B 5 100 - B 5 112 - B 5 132 - B 5 160 - B 5 180 - B 5<br />
200 - 24 250 - 28 250 - 28 250 - 38 350 - 42 350 - 48<br />
100 - B 5 112 - B 5 132 - B 5 160 - B 5 180 - B 5<br />
250 - 28 250 - 28 250 - 38 350 - 42 350 - 48<br />
100 - B 5 112 - B 5 132 - B 5 160 - B 5 180 - B 5<br />
250 - 28 250 - 28 250 - 38 350 - 42 350 - 48<br />
160 - B 5 180 - B 5 200 - V1 / V3 *<br />
350 - 42 350 - 48 400 - 55<br />
160 - B 5 180 - B 5 200 - V1 / V3 *<br />
350 - 42 350 - 48 400 - 55<br />
160 - B 5 180 - B 5 200 - V1 / V3 * 225 - V1 / V3 *<br />
350 - 42 350 - 48 400 - 55 450 - 60<br />
Dimensions in mm<br />
Dimensional and design<br />
changes reserved.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Size Ø i.d.<br />
max.<br />
h<br />
H<br />
AXIAL FLOW FANS AXN SERIES<br />
BELT DRIVE<br />
MAIN DIMENSIONS<br />
R1 TYPE<br />
400 401 438 468 12x 9,5 376 300 615 300<br />
bis 112 B 5<br />
132 S B 5 - 250 436 406 363 370 300 5x 9,5 50<br />
450 450 487 517 12x 9,5 400 335 650 300<br />
bis 112 B 5<br />
132 S B 5 - 250 460 430 387 410 330 5x 9,5 54<br />
500 504 541 571 12x 9,5 450 375 685 300<br />
bis 112 B 5<br />
132 S B 5 - 250 510 480 437 460 380 5x 9,5 65<br />
560 565 605 643 16x11,5 484 420 827 300<br />
bis 112 B 5<br />
132 S B 5 - 250 559 519 470 510 430 5x11,5 80<br />
630 634 674 712 16x11,5 572 470 870 300<br />
bis 112 B 5<br />
132 S B 5 - 250 647 607 558 550 470 5x11,5 115<br />
710 711 751 789 16x11,5 610 525 920 400 132M<br />
B 5<br />
250 685 645 596 620 530 5x11,5 130<br />
800 797 837 875 24x11,5 700 585 970 400 160M B 5 775 735 686 730 640 5x11,5 160<br />
900 894 934 972 24x11,5 746 655 1025 400 160M B 5 831 781 742 730 640 5x11,5 224<br />
1000 1003 1043 1081 24x11,5 830 730 1080 400 160M B 5 927 881 814 830 740 5x14 275<br />
1120 1124 1174 1254 24x11,5 710 760 1175 460 180M B 5 797 751 684 920 820 5x14 320<br />
1250 1261 1311 1391 24x11,5 800 855 1225 460 180M B 5 887 841 774 1030 930 5x14 400<br />
1) Connecting dimensions<br />
according to<br />
DIN 24 154 – Series<br />
c<br />
b1 b<br />
z x d<br />
z x d 1<br />
Ø k Ø D z x d1) L Motor<br />
1 H hmax. c<br />
Max.<br />
size<br />
Flange<br />
type dia<br />
a a1 a2 b b1 z x d1 a 2<br />
Available with airflow direction D only.<br />
L 1<br />
a 1<br />
a<br />
ø i.d.<br />
di.l.<br />
ø k<br />
ø D<br />
010<br />
Weight<br />
without<br />
motor<br />
[~ kg]<br />
Dimensions in mm<br />
Dimensional and design<br />
changes reserved.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Size<br />
z x d<br />
Drawing shows motor in airflow<br />
direction "left"<br />
Configuration with motor in airflow<br />
direction "right" is also available.<br />
Please specify in your purchase order.<br />
Ø<br />
i.d. Ø k Ø D z x d1) L 2 H<br />
AXIAL FLOW FANS AXN SERIES<br />
BELT DRIVE<br />
MAIN DIMENSIONS<br />
R2 TYPE<br />
710 711 751 819 16x11,5 700 525 160 L 180 M 490 400 225 950 950 310 265 905 400 6x11,5 80 80 160<br />
800 797 837 905 24x11,5 800 585 180 L 200 L 570 460 260 1030 1200 355 310 1035 450 6x11,5 120 120 235<br />
900 894 934 1004 24x11,5 900 655 180 L 225 S 574 464 262 1030 1175 360 320 990 450 6x14 120 120 260<br />
1000 1003 1043 1113 24x11,5 1000 730 200 L 225 M 560 420 255 1230 1230 420 370 1180 500 6x14 120 120 340<br />
1120 1124 1174 1254 24x11,5 1100 760 200 L 250 M 610 500 280 1280 1480 470 420 1220 550 6x18 120 140 530<br />
1250 1261 1311 1391 24x11,5 1200 855 225 L 280 S 710 590 330 1315 1600 515 465 1265 600 6x18 140 140 630<br />
1400 1415 1465 1545 24x11,5 1300 930 225 M 280 M 810 690 380 1380 1580 580 530 1330 650 6x18 140 160 780<br />
1600 1587 1637 1717 32x11,5 1400 1020 225 M 315 S 920 790 430 1495 2025 625 565 1435 700 6x18 160 180 1050<br />
1800 1780 1830 1910 32x11,5 1500 1120 225 M 315 M 1020 880 480 1600 2100 700 640 1540 750 6x18 180 200 1300<br />
2000 1997 2047 2167 32x11,5 1500 1250 225 M 315 M 1030 880 480 1900 2100 700 640 1830 750 8x18 200 220 1700<br />
2240<br />
2500<br />
2228<br />
2500<br />
2300<br />
2580<br />
2398 40x14<br />
2670 48x14<br />
on 1375<br />
request<br />
1500<br />
225 M 315 M<br />
225 M 315 M<br />
on request<br />
2100<br />
2600<br />
1) Connecting dimensions according<br />
to DIN 24 154 – Series 3<br />
2) Reinforced types available<br />
against surcharge.<br />
Motor<br />
Type B3<br />
Max. size<br />
rein-<br />
standard<br />
forced 2)<br />
a a1 a2 b bv reinforced<br />
3) Position of antivibration mounts<br />
will be communicated<br />
upon specification.<br />
4) Please check for correct position of the terminal<br />
box when placing your purchase order.<br />
b 1 b 2 b 3 c z x d 1<br />
P (standard)<br />
i.d.<br />
P (reinforced)<br />
011<br />
Weight<br />
without<br />
motor<br />
[~ kg]<br />
standard<br />
Available only with airflow direction D<br />
Dimensions in mm<br />
Dimensional and design<br />
changes reserved.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Wire guard,<br />
inlet side<br />
Size<br />
200<br />
Bellmouth inlet,<br />
with flange<br />
AXIAL FLOW FANS AXO + AXN SERIES<br />
MAIN DIMENSIONS<br />
ACCESSORIES*<br />
Ø d1i.d. b1 Ø d2i.d. Ø k Ø D z x d1) Ø D1 c H a a1 a2 a3 b z x d3 e f<br />
1400 1870 1417 210 930<br />
a<br />
a1 =<br />
=<br />
Casing length<br />
– “ –<br />
+87<br />
+41 1140 1040 5x14 1424 1465 1505 24x11,5 130 100<br />
1600 2087 1587 210 1020 a = Casing length +92 1350 1230 5x18 1596 1637 1677 32x11,5 130 100<br />
1800 2300 1780 210 1120 a1 = – “ – +42 1500 1380 5x18 1789 1830 1870 32x11,5 130 100<br />
2000 2540 1997 210 1250 a = 104 a1 = +44 1750 1600 5x18 2006 2047 2087 32x11,5 160 120<br />
2240<br />
2500<br />
2950 2235 210<br />
upon request<br />
1375<br />
1500<br />
not available<br />
2237<br />
2509<br />
2300 upon 40x14<br />
2580 request 48x14<br />
160 120<br />
160 120<br />
1) Connecting dimensions in accordance<br />
with DIN 24 154 –<br />
Series 3<br />
2) Number and distribution to be<br />
determined according to load<br />
conditions.<br />
Mounting feet Mounting feet for fans with extension casing<br />
or R1 types<br />
Flexible connector Wall ring Matching flange Extension casing<br />
i.d.<br />
i.d.<br />
Installation length<br />
i.d.<br />
Ød 2 i.d.<br />
3) Height under load<br />
will be communicated<br />
upon specification<br />
(value is<br />
calculated individually<br />
for each<br />
purchase order).<br />
(same dimensions as M-D<br />
fan type, refer to page 008)<br />
250 355 255 50 195 185 155 310 280 240 180 5x 9,5 255 286 310 6x 7,0 70 50<br />
280 398 287 56 225 195 165 330 300 270 208 5x 9,5 287 322 352 8x 9,5 80 50<br />
315 447 321 62 240 208 178 358 328 300 240 5x 9,5 321 356 386 8x 9,5 80 50<br />
355 501 362 69 270 221 191 386 356 330 270 5x 9,5 360 395 425 8x 9,5 80 50<br />
400 562 403 78 300 248 218 436 406 370 300 5x 9,5 403 438 468 12x 9,5 80 50<br />
450 631 452 87 335 260 230 460 430 410 330 5x 9,5 452 487 517 12x 9,5 80 50<br />
500 708 509 98 375 285 255 510 480 460 380 5x 9,5 506 541 571 12x 9,5 80 50<br />
560 794 571 109 420 317 277 559 519 510 430 5x11,5 568 605 643 16x11,5 100 70<br />
630 875 640 95 470 361 321 647 607 550 470 5x11,5 637 674 712 16x11,5 100 70<br />
710 972 717 103 525 380 340 685 645 620 530 5x11,5 714 751 785 16x11,5 100 70<br />
800 1081 801 115 585 425 385 775 735 730 640 5x11,5 800 837 875 24x11,5 100 70<br />
900 1214 898 130 655 452 412 825 781 730 640 5x11,5 897 934 972 24x11,5 100 70<br />
1000 1351 1009 145 730 512 466 927 881 830 740 5x14 1006 1043 1081 24x11,5 100 70<br />
1120 1470 1130 160 760 547 501 997 951 920 820 5x14 1133 1174 1214 24x11,5 110 90<br />
1250 1677 1263 185 855 597 551 1097 1051 1030 930 5x14 1270 1311 1351 24x11,5 110 90<br />
This accessory is not suitable<br />
for type M-A fans<br />
(swing-out version).<br />
★ All accessories except for<br />
mounting feet and extension<br />
casings will be supplied<br />
loosely.<br />
012<br />
Rubber antivibration<br />
mounts 2)<br />
V 101 / 103 / 105 / 108<br />
approx.<br />
60<br />
Size<br />
Spring isolators 3)<br />
approx.<br />
80<br />
Dimensions in mm<br />
Dimensional and design<br />
changes reserved.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Brackets for vertical installation (for direct-driven fans)<br />
A B<br />
b<br />
A<br />
Size A � A 1 � b d<br />
d<br />
A 1<br />
C<br />
D<br />
AXIAL FLOW FANS<br />
AXO + AXN SERIES<br />
MAIN ACCESSORIES DIMENSIONS<br />
Brackets<br />
Qty. Size<br />
L 2 L 3 L 4 G C z x d 4)<br />
250 380 414 56 10 3 1 250 50 125 40 200 6x7,0<br />
280 416 450 56 10 4 1 260 60 135 40 210 8x9,5<br />
315 472 520 68 12 4 2 260 60 150 40 230 8x9,5<br />
355 511 559 68 12 4 2 280 80 165 40 250 8x9,5<br />
400 554 602 68 12 4 2 280 60 188 40 280 12x9,5<br />
450 603 651 68 12 4 2 290 70 200 200 350 12x9,5<br />
500 657 705 68 12 4 2 280 60 225 200 390 12x9,5<br />
560 783 831 90 14 4 3 330 70 242 200 430 16x11,5<br />
630 852 900 90 14 4 3 330 70 286 200 470 16x11,5<br />
710 929 977 90 14 4 3 350 70 305 200 540 16x11,5<br />
800 1015 1063 90 14 4 3 520 200 350 200 580 24x11,5<br />
900 1112 1160 90 14 4 3 585 225 373 200 650 24x11,5<br />
1000 1221 1269 90 14 4 3 640 240 415 200 720 24x11,5<br />
1120 1374 1434 100 18 4 4 730 250 450 270 790 24x11,5<br />
1250 1511 1571 100 18 4 4 810 250 500 270 900 24x11,5<br />
1400 1665 1725 100 18 4 4 24x11,5<br />
1600 1837 1897 100 18 4 4 by request<br />
32x11,5<br />
1800 2070 2150 120 18 4 5 32x11,5<br />
2000 2287 2367 120 18 4 5 32x11,5<br />
2240<br />
2500<br />
No brackets available.<br />
not available<br />
40x14<br />
48x14<br />
C<br />
013<br />
Round duct section with automatic<br />
shut-off damper 1)<br />
(For pressure losses refer to page 015).<br />
Øk<br />
L 3<br />
L 2<br />
Wire guard<br />
G<br />
L 4<br />
Outlet cone with<br />
wire guard<br />
Rubber anti-vibration<br />
mountings 2)<br />
V 101 / 103 / 105 / 108<br />
approx. 60<br />
approx. 80<br />
1) The round duct section with automatic shut-off damper can be mounted in any direction. 2) Quantity and distribution to be determined according to load.<br />
3) Height under load will be communicated upon enquiry (this will be calculated for each order). 4) Connecting dimensions per DIN 24154 - Series 3.<br />
Dimensions in mm. Dimensional and design changes reserved.<br />
Size<br />
Spring-type anti-vibration<br />
mountings 3)<br />
z x d
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Why provide diffusers?<br />
<strong>Axial</strong>-flow fans generate a total pressure<br />
increase (�pt) which comprises<br />
a static pressure portion (ps) and a<br />
dynamic one (pd). The impeller of an<br />
axial-flow fan consists of blades and<br />
hub located in the airflow. The result<br />
is a circular flow of considerable velocity.<br />
This high flow velocity (c) gives<br />
rise to a high dynamic pressure.<br />
When an axial-flow fan is allowed to<br />
discharge freely into a room, as is<br />
often the case, the entire dynamic<br />
Diffuser for AXO series fans<br />
Sizes:<br />
315/400/560/630/800/1000-1250<br />
ØD<br />
Øk<br />
Øi.d.<br />
z x d<br />
L<br />
�<br />
Øi.d. 1<br />
ØD 1<br />
AXIAL FLOW FANS AXN SERIES<br />
AXO + AXN SERIES<br />
MAIN DIFFUSER DIMENSIONS<br />
pressure (related to the annular<br />
cross section) ceases to be effective<br />
and must be considered a loss. A diffuser<br />
will reduce the outlet velocity<br />
substantially and thereby prevent<br />
much of this dynamic pressure loss.<br />
In other words, to achieve an otherwise<br />
identical static pressure difference,<br />
the total pressure increase to<br />
be generated can be reduced, and<br />
so can be the output of the fan motor.<br />
Another benefit lies in the increased<br />
outlet surface area, which results in a<br />
Diffuser for AXN series fans<br />
Sizes: 315 bis 1250<br />
ØD<br />
Øi.d.<br />
Øk<br />
z x d<br />
L<br />
Øi.d. 2<br />
ØD2 ØD<br />
Øk<br />
Diffuser for AXN series fans<br />
with interior core<br />
Sizes: 315 bis 1250<br />
Size Ø i.d. Ø i.d. 1 Ø i.d. 2 Ø d3 Ø D Ø D1 Ø D2 Ø D3 Ø k Ø k1 L L1z x d z x d1 315 322 404 360 - 386 424 380 - 356 - 160 - 8 x 9,5 -<br />
355 360 - 404 - 425 - 424 - 395 - 180 - 8 x 9,5 -<br />
400 404 507 451 - 468 527 471 - 438 - 200 _ 12 x 9,5 -<br />
450 451 567 507 - 517 - 527 - 487 - 225 - 12 x 9,5 -<br />
500 507 637 567 282 571 657 587 712 541 674 250 600 12 x 9,5 16 x 11,5<br />
560 567 712 637 315 643 - 657 789 605 751 280 670 16 x 11,5 16 x 11,5<br />
630 637 800 712 355 712 820 732 875 674 837 315 750 16 x 11,5 24 x 11,5<br />
710 712 894 800 397 789 - 820 972 751 934 355 850 16 x 11,5 24 x 11,5<br />
800 800 1006 894 446 875 1026 914 1081 837 1043 400 950 24 x 11,5 24 x 11,5<br />
900 894 1128 1006 502 972 - 1026 1254 934 1174 450 1060 24 x 11,5 24 x 11,5<br />
1000 1006 1264 1128 562 1081 1284 1148 1391 1043 1311 500 1200 24 x 11,5 24 x 11,5<br />
1120 1128 1418 1264 630 1214 1438 1284 1545 1174 1465 560 1340 24 x 11,5 24 x 11,5<br />
1250 1264 1589 1416 710 1351 1609 1436 1717 1311 1637 630 1510 24 x 11,5 32 x 11,5<br />
Diffuser dimensions for sizes 1400 through to 2500 are available upon request.<br />
� A flat flange must be provided for duct connection. Dimensions in mm. Dimensional and design changes reserved.<br />
�<br />
Øi.d.<br />
z x d<br />
Ød 3<br />
L 1<br />
014<br />
more uniform application of the airflow<br />
to downstream components.<br />
For <strong>TLT</strong> diffusers with interior core<br />
for use with AXN series axial-flow<br />
fans and for diffusers without interior<br />
core for AXN or AXO series fans,<br />
please enquire with our headquarter<br />
or field staff. These products will be<br />
rated using special computer software.<br />
Øi.d. 1<br />
z x d 1<br />
Øk1 ØD3
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
AXIAL FLOW FANS AXN SERIES<br />
AXO + AXN SERIES<br />
ACCESSORIES<br />
Pressure loss associated with automatic shut-off dampers<br />
Pressure loss � ps [Pa] ➝<br />
Round duct section with automatic shut-off damper<br />
300<br />
200<br />
150<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
C G L 4<br />
The flow velocity c can be obtained<br />
from the characteristic curve sheets.<br />
(Values for 2.5 D ducting).<br />
The pressure loss � ps can be optimized<br />
by means of adjustable weights.<br />
Flow velocity c [m/s] ➝<br />
z x d<br />
015<br />
For dimensions refer to page 013.<br />
Mounting positions:<br />
- horizontal<br />
- upward<br />
- downward<br />
10 20 30 40 50
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Complimentary to our AXN 12/56 series<br />
(with outlet guide vanes) we supply specially<br />
developed round silencers in 13 sizes.<br />
These units substantially reduce the<br />
sound level.<br />
They are easily fitted on the fan inlet or outlet<br />
side, without any additional intermediateelements.<br />
The silencer housing consists of Sendzimir<br />
galvanized sheet steel.<br />
Mounting nuts are provided internally on<br />
the connecting face sides (hole pattern as<br />
per DIN 24154 – Series 3).<br />
The interspace between the exterior barrel<br />
and the interior sleeve (made of galvanized<br />
perforated sheet metal) as well as<br />
the interior core are filled with a non-combustible<br />
acoustic damping material.<br />
(The sketch shows an axial-flow fan<br />
with extension casing and one round<br />
silencer each on its inlet and outlet<br />
sides).<br />
Insertion attenuation per silencer<br />
Insertion attenuation in dB<br />
Size<br />
For higher attenuations several silencers of identical<br />
diameter may be arranged in series.<br />
Octave centre frequency fo [Hz]<br />
63 125 250 500 1000 2000 4000 8000<br />
315 7 13 17 22 24 30 23 19<br />
355 7 13 17 22 24 30 23 19<br />
400 6 12 16 21 23 29 22 18<br />
450 6 11 15 19 21 26 20 16<br />
500 5 10 14 17 19 23 18 14<br />
560 4 9 13 16 18 22 17 13<br />
630 3 8 12 15 17 20 16 12<br />
710 6 11 16 19 21 20 17 13<br />
800 5 10 14 17 19 18 16 12<br />
900 4 9 13 16 18 16 13 9<br />
1000 3 8 12 15 17 14 12 8<br />
1120 4 8 13 16 18 15 13 9<br />
1250 4 9 13 17 18 16 13 9<br />
Static pressure loss �ps [Pa] ➝<br />
(per silencer)<br />
224<br />
180<br />
140<br />
112<br />
90<br />
71<br />
56<br />
45<br />
35,5<br />
28<br />
22,4<br />
2000<br />
2500<br />
3150<br />
Nominal-Ø 315<br />
4000<br />
Volume flow [m 3/h] ➝<br />
5000<br />
Ø 355<br />
AXIAL FLOW FANS AXN SERIES<br />
ROUND SILENCERS - TSR<br />
Ø 400<br />
6300<br />
Size Ø i.d. Ø D Ø k Ø d 1 L z x ø d 2<br />
8000<br />
Ø 450<br />
Ø 500<br />
10000<br />
12500<br />
Ø 560<br />
16000<br />
Ø 630<br />
20000<br />
Ø 710<br />
25000<br />
Ø 800<br />
31500<br />
Ø 900<br />
40000<br />
Ø 1000<br />
50000<br />
Ø 1120<br />
63000<br />
Ø 1250<br />
80000<br />
100000<br />
016<br />
Weight<br />
[kg]<br />
315 320 490 356 180 930 8 x M 8 31<br />
355 359 525 395 200 930 8 x M 8 39<br />
400 401 570 438 224 930 12 x M 8 50<br />
450 450 620 487 250 930 12 x M 8 56<br />
500 504 675 541 280 930 12 x M 8 60<br />
560 565 735 605 315 930 16 x M 8 68<br />
630 634 885 674 355 930 16 x M 8 76<br />
710 711 960 751 400 1430 16 x M 8 120<br />
800 797 1050 837 450 1430 24 x M 8 137<br />
900 894 1145 934 500 1430 24 x M 8 153<br />
1000 1003 1255 1043 560 1430 24 x M 8 167<br />
1120 1124 1375 1174 630 1430 24 x M 8 207<br />
1250 1261 1515 1311 710 1430 24 x M 8 254<br />
i.d.<br />
This diagram shows the<br />
static pressure loss<br />
caused by insertion of a<br />
silencer into a matching<br />
duct of the diameter<br />
shown.<br />
125000<br />
Dimensional and design changes reserved – Dimensions in mm
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Description:<br />
shell-design, easy dismanteling, reusable.<br />
For acoustic insulation and/or<br />
reduction of thermal emission from<br />
the fan casing.<br />
The design of this insulation - compared<br />
to some other types - allows a<br />
more space saving installation with<br />
improved accessibility as well as considerably<br />
easier testing and maintenance<br />
of the fan.<br />
The Insulation consists of:<br />
A certian number of shells acc. to fan<br />
length, split into upper and lower<br />
shell, made of galvanized steel<br />
sheets for connecting the shells in the<br />
vicinity of the fan´s mounting feet as<br />
well as insulated connections to flexible<br />
connectors or ducts. Insulating<br />
material made of mineral wool with<br />
wire gauze on one side, thickness 80<br />
mm and 120 mm respetcively, not inflammable<br />
class A1 as per DIN 4102<br />
T4, specific density 60-80 kg/m3.<br />
These mats are fixed to the shells.<br />
Total insulation value<br />
<strong>Axial</strong> Fan with insulated casing<br />
[A-weighted]<br />
approximative calculation of the Aweighted<br />
acoustic power, emitted<br />
from the insulated fan casing<br />
L WAcasing = L Wvent. – De chart<br />
Insulation value [DE]<br />
Insulation value [De]<br />
dB (A) weighted<br />
f D [Hz] 500 250 125<br />
Size<br />
315-560<br />
Size<br />
630-1600<br />
35 35 36<br />
37 38 37<br />
(please ask for exact value of insulation<br />
within the octave band)<br />
ACOUSTIC INSULATION<br />
FOR AXO + AXN SERIES<br />
<strong>Axial</strong> Fan AXN 12/56/1000 with acoustic insulation<br />
017
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Examples for horizontal installation<br />
ACOUSTIC INSULATION<br />
MAIN DIMENSIONS<br />
Type A Type B Type C<br />
L2 L3 L<br />
Insulation<br />
3<br />
Type D<br />
L 4<br />
*<br />
In case of horizontal outdoor installation a canope is to be erected covering<br />
complete insulation (available upon request)<br />
Examples for vertical installation<br />
Insulation<br />
b<br />
➞<br />
d<br />
A 2<br />
A 3<br />
L 3<br />
D 2<br />
Size L 3 A 2 A 3 b d<br />
355 495 631 679 68 12<br />
400 564 674 722 68 12<br />
450 600 723 771 68 12<br />
500 675 777 825 68 12<br />
560 726 903 951 90 14<br />
630 858 1014 1066 90 14<br />
710 915 1091 1143 90 14<br />
800 1050 1177 1229 90 14<br />
900 1119 1274 1326 90 14<br />
1000 1245 1383 1435 90 14<br />
1120 1350 1504 1564 100 18<br />
1250 1500 1641 1701 100 18<br />
Insulation<br />
dimensions in mm<br />
for dimensions please<br />
see page 019<br />
018<br />
This insulation should not be used for<br />
vertical outdoor installation
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Size D 2 L 2 L 3 L 4<br />
355 525 330 495 660<br />
400 570 376 564 752<br />
450 620 400 600 800<br />
500 675 450 675 900<br />
560 735 484 726 968<br />
630 885 572 858 1144<br />
Fan - Flexible connector - angular duct<br />
Insulation<br />
loosely supplied<br />
Impeller of<br />
axial fan<br />
Connecting<br />
piece<br />
Fan - Flexible Connector - Duct<br />
Impeller of<br />
axial fan<br />
Connecting piece<br />
ACOUSTIC INSULATION<br />
MAIN DIMENSIONS<br />
CONNECTION DETAILS<br />
Adhesive tape<br />
230<br />
Flexible sleeve<br />
Insulation<br />
(loosely<br />
supplied)<br />
Flexible<br />
Connector<br />
200<br />
230<br />
Flexible sleeve<br />
Flexible<br />
Connector<br />
200<br />
Size D 2 L 2 L 3 L 4<br />
710 960 610 915 1220<br />
800 1050 700 1050 1400<br />
900 1145 746 1119 1492<br />
1000 1255 830 1245 1660<br />
1120 1375 900 1350 1800<br />
1250 1515 1000 1500 2000<br />
Tensioner<br />
Tensioner<br />
Adhesive tape<br />
019<br />
Angular<br />
duct<br />
(customersupplied)<br />
Insulated duct<br />
(customersupplied)
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Acoustic level<br />
The total acoustic power level LW.Vent. (in dB) of an axial-flow fan can be obtained<br />
directly from the characteristic<br />
data sheets for each operating point.<br />
Starting from this value, the A-weighted<br />
acoustic power level LWA and the<br />
1. Acousting power level emitted into the duct<br />
The level of acoustic power an axial-flow fan emits into the<br />
ducting is used for calculating the sound power characteristics<br />
of downstream systems, e.g., silencers.<br />
The levels are calculated as follows:<br />
Lwvent. [dB] = total acoustic power emitted by the fan,<br />
(please see respective characteristic curve<br />
sheets)<br />
LwA vent. [dB] = A-weighted acoustic power level, according<br />
to the equation<br />
Lw A vent.<br />
= Lw vent. – portion 1.1 [dB]<br />
Lw rel vent. [dB]= relative acoustic power level as expressed<br />
by the equation<br />
Lw rel vent.<br />
= Lw vent. – portion 1.2 [dB]<br />
2. Acoustic power emitted from the fan inlet or outlet<br />
opening<br />
To determine the sound levels at a given installation site,<br />
it is usually necessary to know the level of acoustic power<br />
emitted from the fan’s inlet or outlet opening. The adjacent<br />
tables are based on the outlet reflection pattern assumed<br />
in VDI 2081, Case 2.<br />
LwA op. [dB] = A-weighted level of acoustic power emitted from<br />
the fan’s opening, expressed by the equation<br />
Lw A op.<br />
Lw rel op.<br />
Lw rel op.<br />
Lwvent. LwAvent. Amount A<br />
Amount-linear level<br />
= Lw vent. – portion 2.1 [dB]<br />
= relative level of acoustic power emitted from the<br />
fan’s opening, expressed by the equation<br />
= Lw vent. – portion 2.2 [dB]<br />
Blade frequency of the fan ist calculated from the number of blades<br />
z and the fan speed n [rpm].<br />
fD = –––––– [s-1 z · n<br />
]<br />
60<br />
fD<br />
Hz<br />
63 125 250 500 1000 2000 4000 8000<br />
AXIAL FLOW FANS AXO SERIES<br />
ACOUSTIC DATA<br />
relative acoustic power level L Wrel.<br />
can be determined using the tables<br />
below. These values are available as<br />
the acoustic power emitted into the<br />
duct and as the acoustic power emitted<br />
from the fan inlet or outlet opening,<br />
respectively. The values given<br />
were taken from measurements as<br />
Lw rel.vent.<br />
z · n<br />
fD = ––––<br />
60<br />
500<br />
250<br />
125<br />
63<br />
31,5<br />
Portion 1.1<br />
4<br />
6<br />
7<br />
8<br />
8<br />
020<br />
per EN 25136 (formerly DIN 45 635,<br />
Part 9) duct testing method.<br />
<strong>Axial</strong> Smoke Exhaust Fan AXO (without guide vanes)<br />
Size*<br />
315<br />
400<br />
500<br />
630<br />
800<br />
1000<br />
fD =<br />
z · n<br />
60<br />
500<br />
250<br />
125<br />
500<br />
250<br />
125<br />
63<br />
500<br />
250<br />
125<br />
63<br />
500<br />
250<br />
125<br />
63<br />
500<br />
250<br />
125<br />
63<br />
250<br />
125<br />
63<br />
Portion<br />
2.1<br />
4<br />
6<br />
8<br />
4<br />
6<br />
7<br />
8<br />
4<br />
6<br />
7<br />
8<br />
4<br />
6<br />
7<br />
8<br />
4<br />
6<br />
7<br />
8<br />
6<br />
7<br />
8<br />
Portion 1.2 at mid-octave frequency [Hz]<br />
63 125 250 500 1000 2000 4000 8000<br />
12 9 7 5 11 12 14 15<br />
9 7 4 10 12 13 15 17<br />
6 4 10 11 13 14 16 21<br />
2 8 10 11 13 15 19 24<br />
6 8 9 11 13 17 21 26<br />
Portion 2.2 at mid-octave frequency [Hz]<br />
63 125 250 500 1000 2000 4000 8000<br />
24 17 11 6 11 12 14 15<br />
21 15 8 12 12 13 15 17<br />
18 12 14 13 13 14 16 21<br />
22 16 10 5 11 12 14 15<br />
20 13 7 11 12 13 15 17<br />
17 10 13 12 13 14 16 21<br />
13 15 13 12 13 15 19 24<br />
21 14 9 5 11 12 14 15<br />
18 12 6 11 12 13 15 17<br />
15 9 11 11 13 14 16 21<br />
12 13 12 12 13 15 19 24<br />
20 13 8 5 11 12 14 15<br />
17 11 6 10 12 13 15 17<br />
14 8 11 11 13 14 16 21<br />
10 12 11 11 13 15 19 24<br />
18 12 8 5 11 12 14 15<br />
15 10 5 10 12 13 15 17<br />
12 7 10 11 13 14 16 21<br />
9 11 11 11 13 15 19 24<br />
14 9 5 10 12 13 15 17<br />
11 6 10 11 13 14 16 21<br />
8 10 10 11 13 15 19 24<br />
*Intermediate values to be obtained by interpolation.<br />
Note:<br />
Portions 1.1 / 1.2 / 2.1 / 2.2 to be taken frome the above<br />
spreadsheets.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Acoustic level<br />
The total acoustic power level LW.Vent. (in dB) of an axial-flow fan can be obtained<br />
directly from the characteristic<br />
data sheets for each operating point.<br />
Starting from this value, the A-weighted<br />
acoustic power level LWA and the<br />
1. Acousting power level emitted into the duct<br />
The level of acoustic power an axial-flow fan emits into the<br />
ducting is used for calculating the sound power characteristics<br />
of downstream systems, e.g., silencers.<br />
The levels are calculated as follows:<br />
Lwvent. [dB] = total acoustic power emitted by the fan,<br />
(please see respective characteristic curve<br />
sheets)<br />
LwA vent. [dB] = A-weighted acoustic power level, according<br />
to the equation<br />
Lw A vent.<br />
Lwvent. LwAvent. Amount A<br />
Amount linear-level<br />
= Lw vent. – portion 1.1 [dB]<br />
Lw rel vent. [dB]= relative acoustic power level as expressed<br />
by the equation<br />
Lw rel vent.<br />
= Lw vent. – portion 1.2 [dB]<br />
2. Acoustic power emitted from the fan inlet or outlet<br />
opening<br />
To determine the sound levels at a given installation site,<br />
it is usually necessary to know the level of acoustic power<br />
emitted from the fan’s inlet or outlet opening. The adjacent<br />
tables are based on the outlet reflection pattern assumed<br />
in VDI 2081, Case 2.<br />
LwA op. [dB] = A-weighted level of acoustic power emitted from<br />
the fan’s opening, expressed by the equation<br />
Lw A op.<br />
Lw rel op.<br />
Lw rel op.<br />
= Lw vent. – portion 2.1 [dB]<br />
= relative level of acoustic power emitted from the<br />
fan’s opening, expressed by the equation<br />
= Lw vent. – portion 2.2 [dB]<br />
Blade frequency of the fan ist calculated from the number of blades<br />
z and the fan speed n [rpm].<br />
fD = –––––– [s-1 z · n<br />
]<br />
60<br />
fD<br />
Hz 63 125 250 500 1000 2000 4000 8000<br />
AXIAL FLOW FANS AXN SERIES<br />
ACOUSTIC DATA<br />
relative acoustic power level L Wrel.<br />
can be determined using the tables<br />
below. These values are available as<br />
the acoustic power emitted into the<br />
duct and as the acoustic power emitted<br />
from the fan inlet or outlet opening,<br />
respectively. The values given<br />
were taken from measurements as<br />
Lw rel.vent.<br />
<strong>Axial</strong> Smoke Exhaust Fan AXN (with guide vanes)<br />
z · n<br />
fD = ––––<br />
60<br />
500<br />
250<br />
125<br />
63<br />
31,5<br />
Size*<br />
315<br />
400<br />
500<br />
630<br />
800<br />
1000<br />
1250<br />
fD =<br />
z · n<br />
60<br />
500<br />
250<br />
125<br />
500<br />
250<br />
125<br />
63<br />
500<br />
250<br />
125<br />
63<br />
500<br />
250<br />
125<br />
63<br />
500<br />
250<br />
125<br />
63<br />
250<br />
125<br />
63<br />
250<br />
125<br />
63<br />
Portion 1.1<br />
2<br />
5<br />
7<br />
10<br />
11<br />
Portion<br />
2.1<br />
3<br />
6<br />
8<br />
3<br />
5<br />
8<br />
10<br />
2<br />
5<br />
8<br />
10<br />
2<br />
5<br />
8<br />
10<br />
2<br />
5<br />
7<br />
9<br />
5<br />
7<br />
9<br />
5<br />
7<br />
9<br />
Portion 1.2 at mid-octave frequency [Hz]<br />
021<br />
per EN 25136 (formerly DIN 45 635,<br />
Part 9) duct testing method.<br />
63 125 250 500 1000 2000 4000 8000<br />
13 10 8 6 6 12 15 16<br />
10 8 5 5 11 14 16 18<br />
7 5 5 11 14 16 18 22<br />
4 4 10 13 15 17 21 25<br />
3 9 12 13 15 20 24 28<br />
Portion 2.2 at mid-octave frequency [Hz]<br />
63 125 250 500 1000 2000 4000 8000<br />
25 18 12 7 6 12 15 16<br />
23 16 9 7 12 14 16 18<br />
20 13 9 12 14 16 18 22<br />
23 17 11 6 6 12 15 16<br />
21 14 9 6 11 14 16 18<br />
18 11 8 12 14 16 18 22<br />
15 11 13 14 15 17 21 25<br />
22 15 10 6 6 12 15 16<br />
20 13 8 6 11 14 16 18<br />
17 10 7 11 14 16 18 22<br />
14 9 12 13 15 17 21 25<br />
21 14 9 6 6 12 15 16<br />
18 12 7 6 11 14 16 18<br />
15 9 6 11 14 16 18 22<br />
12 8 11 13 15 17 21 25<br />
19 13 9 6 6 12 15 16<br />
17 11 6 5 11 14 16 18<br />
14 8 6 11 14 16 18 22<br />
11 7 11 13 15 17 21 25<br />
15 10 6 5 11 14 16 18<br />
12 7 5 11 14 16 18 22<br />
9 6 10 13 15 17 21 25<br />
14 9 6 5 11 14 16 18<br />
11 6 5 11 14 16 18 22<br />
9 5 10 13 15 17 21 25<br />
*Intermediate values to be obtained by interpolation.<br />
Note:<br />
Portions 1.1 / 1.2 / 2.1 / 2.2 to be taken frome the above<br />
spreadsheets.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Application example for<br />
axial-flow fans<br />
The volume flow measuring system<br />
determines the operating volume flow<br />
of an axial fan installed in an air-handling<br />
installation. The system greatly<br />
facilitates the determination of fan volume<br />
flow. As a result, the cost and effort<br />
required for in-duct measurements<br />
on the system side, as often<br />
carried out during commissioning,<br />
can be significantly reduced. Moreover,<br />
adjustments are faster and easier<br />
to carry out.<br />
The measuring accuracy of the volume-flow<br />
measuring system is approx.<br />
± 5%.<br />
Description of the measuring<br />
system<br />
The volume flow measuring system is<br />
firmly mounted on the fan to determine<br />
the volume flow in its installed condition.<br />
The reading is obtained by a<br />
simple differential-pressure measurement<br />
between the sockets of the<br />
pressure measuring lines connected<br />
to the measuring system. The calibration<br />
curve is prepared individually, taking<br />
into account fan-specific parameters.<br />
Key influencing variables include<br />
fan type, inlet density, rpm and<br />
fan design size. Being established individually<br />
with reference to the above<br />
parameters, the calibration curve is<br />
not transferable to other fan types<br />
Options<br />
Adirect automatic volume flow measurement<br />
can be implemented by<br />
means of root-extracting differential<br />
pressure transducers or suitable<br />
electronic evaluation units. The following<br />
equation may be used for this<br />
purpose:<br />
Volume flow calculation:<br />
V = k x A x<br />
� 2 x d<br />
p<br />
VOLUME FLOW MEASURING SYSTEM VDE<br />
FOR CENTRIFUGAL ROOF FANS<br />
AND AXIAL FLOW FANS<br />
and sizes. At fan operating speeds<br />
deviating from the rated rpm level,<br />
major inaccuracies will be obtained,<br />
especially when the fan is running at<br />
slower speeds.<br />
The measuring system consists of an<br />
additional casing extension made of<br />
sheet steel, pre-installed measuring<br />
lines for the pressure measurement,<br />
and a sheet aluminium hub body attached<br />
to, and rotating with, the fan impeller.<br />
The pressure measurement<br />
ring line consists of plastic hose as<br />
employed in pneumatic applications,<br />
as well as brass screw-in adapters.<br />
The four measuring points, spaced<br />
evenly over the circumference, are<br />
connected into a ring line by means of<br />
T-fittings. The connection to a pressure<br />
measuring instrument is likewise<br />
made via a T-fitting.<br />
Technical description<br />
The calibration curves can be computed<br />
for flow medium throughput conditions<br />
as habitually employed in ventilation<br />
technology, and apply to air only.<br />
The measuring system is standardized<br />
for AXN series fans in the 315<br />
to 2000 size range. It is recommended<br />
to use the volume flow measuring<br />
device only at blade angles equal to,<br />
or exceeding, 10 degrees so as to to<br />
maximize the accuracy of the reading.<br />
At blade angles below 10 deg.,<br />
the magnitude of the differential pressure<br />
indication will not suffice for an<br />
Calculation of k:<br />
Correction factor:<br />
k = f (Re, NG, n)<br />
Reynolds number:<br />
c x Dh Re = x<br />
�<br />
Hydraulic diameter:<br />
Dh = A· 4<br />
�<br />
�<br />
Rotational Speed:<br />
n [rpm]<br />
Reference cross section:<br />
NG [mm]<br />
022<br />
unambiguous volume flow measurement.<br />
The accuracy of the system depends<br />
essentially on its installation<br />
conditions and on the inlet-side approach<br />
flow situation. An irregular or<br />
swirl-impaired inlet airflow will reduce<br />
the accuracy of the volume flow measuring<br />
system. The differential pressure<br />
measurement can be carried out<br />
with the aid of electronic differential<br />
pressure sensors or other standard<br />
commercial transducers, whether<br />
mechanical or hydrostatic. The measuring<br />
range of the differential pressure<br />
instrument should be 0 - 2000<br />
Pa, at a resolution of 1 Pa. The measuring<br />
tolerance of the instrument<br />
employed should be better than ± 2.5<br />
of the measured value.<br />
Uses:<br />
The system may be used for the following<br />
<strong>TLT</strong> axial-flow fans:<br />
Series AXN 12/56<br />
AXN 9/56<br />
AXN 6/56<br />
BVAXN 12/56<br />
BVAXN 9/56<br />
BVAXN 6/56<br />
Flow velocity in the annulus area:<br />
c [m/s]<br />
Kinematic viscosity:<br />
� [kg/ms]<br />
Inlet density:<br />
[kg/m3] �<br />
Reference surface area for the volume<br />
flow determination:<br />
A= [m2 ] = annulus area of the blading<br />
d P= Differential pressure [Pa] at the<br />
volume flow measuring point
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Rating sheet for a volume flow<br />
measuring system<br />
Example given for an AXN<br />
12/56/1000 axial-flow fan<br />
Nominal size NG 1000<br />
Rotational speed n 1500 rpm<br />
Tip speed u2 79 m/s<br />
Density 1,2 kg/m3 Dynamic viscosity � 1,80E-05 Pa s<br />
Reference cross-section A ring 0,5391 m 2<br />
Reference diameter Dh ref 0,8285 m<br />
Rated fan total pressure increase dpt 500 Pa<br />
Rated volume flow VA 45000 m3/h Rated flow within measuring range* VA > 32100 m3/h Correction factor at VA k 2,13<br />
Differential pressure under rating conditions dp 71 Pa<br />
* At smaller volume flows the differential pressure values are of insufficient magnitude.<br />
The accuracy of the volume flow measuring system depends on the pressure gauge employed as well as on the flow approach situation. Under unperturbed<br />
incoming flow condition and taking into account the inlet density, the tolerance is approx. 5% of the actual volume flow value.<br />
Table of values:<br />
VOLUME FLOW MEASURING SYSTEM VME<br />
FOR AXIAL-FLOW FANS<br />
Input data Calculated data Operating limits<br />
�<br />
Item Reynolds number<br />
Correction coefficient for<br />
volume flow measurement<br />
Differential pressure Volume flow rate<br />
Rec k dpk V<br />
(-) (-) (Pa) (m3/h) 1 150 000 undefined range<br />
2 300 000 undefined range<br />
3 450 000 undefined range<br />
4 600 000 10861,97 0 21 364<br />
5 750 000 36,35 0 26 705<br />
6 900 000 7,06 3 32 046<br />
7 1 050 000 3,36 20 37 386<br />
8 1 200 000 2,37 52 42 727<br />
9 1 350 000 2,00 92 48 068<br />
10 1 500 000 1,84 134 53 409<br />
11 1 650 000 1,75 179 58 750<br />
12 1 800 000 1,70 226 64 091<br />
13 1 950 000 1,67 274 69 432<br />
14 2 100 000 1,65 326 74 773<br />
15 2 250 000 1,64 380 80 114<br />
16 2 400 000 1,63 437 85 455<br />
17 2 550 000 1,62 498 90 796<br />
18 2 700 000 1,62 561 96 137<br />
19 2 850 000 1,62 628 101 477<br />
20 3 000 000 1,61 698 106 818<br />
21 3 150 000 1,61 772 112 159<br />
023
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Rating sheet for a volume flow<br />
measuring system<br />
Example given for an AXN<br />
12/56/1000 axial-flow fan<br />
Differential pressure [Pa]<br />
900<br />
800<br />
700<br />
600<br />
500<br />
400<br />
300<br />
200<br />
100<br />
Density 1,2 kg/m 3<br />
Density 1,1 kg/m 3<br />
Density 1,0 kg/m 3<br />
Density 0,9 kg/m 3<br />
Density 1,3 kg/m 3<br />
VOLUME FLOW MEASURING SYSTEM VME<br />
FOR AXIAL-FLOW FANS<br />
Nominal size NG 1000<br />
Rotational speed n 1500 rpm<br />
Tip speed u2 79 m/s<br />
Density 1,2 kg/m3 Dynamic viscosity � 1,80E-05 Pa s<br />
Reference cross-section A ring 0,5391 m 2<br />
Reference diameter Dh ref 0,8285 m<br />
Rated fan total pressure increase dpt 500 Pa<br />
Rated volume flow VA 45000 m3/h Rated flow within measuring range* VA > 32100 m3/h Correction factor at VA k 2,13<br />
Differential pressure under rating conditions dp 71 Pa<br />
* At smaller volume flows the differential pressure values are of insufficient magnitude.<br />
The accuracy of the volume flow measuring system depends on the pressure gauge employed as well as on the flow approach situation. Under unperturbed<br />
incoming flow condition and taking into account the inlet density, the tolerance is approx. 5% of the actual volume flow value.<br />
Input data Calculated data Operating limits<br />
�<br />
0<br />
0 20000 40 000 60 000 80 000 100 000 120 000<br />
Volume flow [m 3 /h]<br />
024
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Application description<br />
1. Determine the differential pressure<br />
between the two measuring points<br />
(marked „-“ and „+“) using a suitable<br />
differential pressure gauge.<br />
2. Determine the operating volume<br />
flow as a function of the inlet density<br />
from the „volume flow over differential<br />
pressure“ diagram available for each<br />
fan.<br />
Alternatively:<br />
Determine the volume flow automatically<br />
using a differential pressure<br />
transducer and analyzer unit.<br />
Nominal<br />
size (1)<br />
a MS b MS k L<br />
315 50 1 80 2 88 150<br />
355 57 1 91 2 99 165<br />
400 64 1 102 2 112 188<br />
450 72 1 115 2 126 200<br />
500 80 1 128 2 140 225<br />
560 90 1 143 2 157 242<br />
630 101 1 161 2 176 286<br />
710 114 1 181 2 199 305<br />
800 128 1 204 2 224 350<br />
900 144 1 230 2 252 373<br />
1000 160 1 255 2 280 415<br />
1120 179 1 286 2 314 450<br />
1250 200 1 319 2 350 500<br />
1400 224 1 357 2 392 900<br />
1600 256 1 408 2 448 900<br />
1800 288 1 459 2 504 1120<br />
2000 320 1 510 2 560 1120<br />
(1) Ø DNG<br />
VOLUME FLOW MEASURING SYSTEM VME<br />
FOR AXIAL-FLOW FANS<br />
Duct extension<br />
Inlet cap<br />
Differential<br />
pressure gauge<br />
AXN Series axial-flow fan with VME system<br />
MS 1<br />
Ø DNG<br />
L<br />
a b<br />
k<br />
Measurement ring line (2)<br />
L<br />
MS 2<br />
025
Item<br />
Nr.<br />
Qty. Description<br />
or<br />
or<br />
– 026 –<br />
Volume flow measuring system for in-duct<br />
integration into axial-flow fans VME AX<br />
consisting of an aluminium inlet cap mounting<br />
on the hub of the axial fan impeller<br />
- Natural aluminium finish<br />
- Powder-coated in RAL colours (unicolour)<br />
Duct extension with flange, R3 hole pattern<br />
- Powder-coated steel in RAL colours (unicolour)<br />
- Galvanized steel<br />
- Measurement ring lines (2 pcs.), made of plastic,<br />
with adapters for connection of a pressure gauge<br />
- Documentation including flow rate calibration curve<br />
The volume flow measuring system can only be used<br />
in conjunction with an AXN / ZAXN / BVAXN or BVZAXN<br />
series fan.<br />
The operating limits of the measuring system are to be<br />
noted.<br />
Manufacturer: <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Type: VME-AX<br />
Unit price<br />
2<br />
Total<br />
2
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Drive motors<br />
<strong>Axial</strong>-flow fans of the AXO/AXN type<br />
are powered by surface-cooled motors<br />
according to IEC standards. Up<br />
to motor size 180, standard motors<br />
with type V1, B14 or B5 flanges are<br />
used, depending on the mounting position<br />
(AXO types are always supplied<br />
with B3 flanges). From motor size 200<br />
upwards, standard B3, V5 or V6 footmounted<br />
units are selected, again depending<br />
on the mounting position.<br />
These motors meet VDE 0530 specifications<br />
for electrical machinery, protection<br />
class IP 44, insulation class B,<br />
fitted with noise-tested antifriction<br />
bearings.<br />
Standard versions of these axial-flow<br />
fans are rated for a maximum operating<br />
temperature of 70°C since their<br />
impeller material is not resistant to<br />
higher thermal loads.<br />
Motor bearings require periodic regreasing.<br />
For guidance, the following<br />
lubrication intervals are given:<br />
Motor sizes 63 - 100<br />
n = 3000 rpm 5 000 operating hours<br />
n = 1500 rpm 10 000 operating hours<br />
n = 1000 rpm 20 000 operating hours<br />
n = 750 rpm 20 000 operating hours<br />
Motor sizes 112 - 160<br />
n = 3000 rpm 4 000 operating hours<br />
n = 1500 rpm 8 000 operating hours<br />
n = 1000 rpm 16 000 operating hours<br />
n = 750 rpm 16 000 operating hours<br />
Motor sizes 180 & 200<br />
n = 1500 rpm 5 000 operating hours<br />
n = 1000 rpm 7 000 operating hours<br />
n = 750 rpm 10 000 operating hours<br />
Motor sizes 225 - 280<br />
n = 1500 rpm 2 500 operating hours<br />
n = 1500 rpm 4 000 operating hours<br />
n = 750 rpm 6 000 operating hours<br />
AXIAL FLOW FANS<br />
ELECTRICAL NOTES<br />
GENERAL / MOTOR PROTECTION<br />
In any case, the motor manufacturer's<br />
detailed instructions must be observed<br />
(see motor nameplate). Motors<br />
up to size 200 in standard version<br />
have no relubrication device, on these<br />
motors bearing housings must be<br />
opened to apply new grease. Motors<br />
of size 225 and upwards have a relubricating<br />
device with grease valve.<br />
Single-speed motors can be run on<br />
230 V or 400 V three-phase a.c. (50<br />
Hz); pole-changing motors require a<br />
400 V / 50 Hz three-phase a.c. operating<br />
voltage.<br />
Other voltages, frequencies and class<br />
ratings may be available as special<br />
versions.<br />
Connecting diagrams<br />
Three-phase a.c. motor<br />
Connection: �/Y<br />
Ratio 1 : � 3<br />
e.g.,<br />
230 / 400 V<br />
400 V<br />
500 V<br />
Low voltage High voltage<br />
Motor protection<br />
First of all each power circuit must be<br />
fused. Fuses, however, can only protect<br />
switchgear and mains feeders<br />
against short circuits. They do not<br />
protect the motor from overload. Due<br />
to the breakaway starting current,<br />
which is many times (4 to 6x) the nominal<br />
current, these fuses must be<br />
rated higher than the nominal motor<br />
current would nominally require. To<br />
protect the motor itself, the following<br />
options are available:<br />
027<br />
1. Thermal overcurrent release<br />
(bimetal protection switch)<br />
This current-related motor protection<br />
device is set to the nominal voltage<br />
stated on the motor nameplate. In the<br />
case of an overcurrent it interrupts the<br />
motor contactor holding circuit. This<br />
is the most common overload protection<br />
system adopted for electric motors<br />
nowadays.<br />
2. Thermocouples<br />
In this system, thermostatic circuitbreakers<br />
are incorporated into the<br />
motor winding. In the case of an overtemperature<br />
they open or close a circuit.<br />
They are wired to the motor terminal<br />
panel.<br />
3. Full thermistor protection<br />
Thermistors are temperature-sensitive<br />
resistors which change their resistance<br />
briskly at a given temperature.<br />
Three such components are incorporated<br />
into the motor winding. In conjunction<br />
with a release device they<br />
provide an effective motor temperature<br />
monitoring function.<br />
Electric motors are primarily at risk<br />
from overcurrents due to overloading<br />
or phase failure. For this reason, the<br />
thermal overcurrent release is the<br />
most widespread motor protection<br />
system. Thermal cutouts or thermistors<br />
monitor the winding temperature<br />
directly. Since the winding may<br />
overheat not only from excessive electrical<br />
loads (i.e., overcurrent) but<br />
also due to a malfunction of the<br />
motor-cooling or an increase in the<br />
coolant temperature, these last-mentioned<br />
devices are also referred to as<br />
"full protection" systems. They are<br />
recommended wherever motors are<br />
at risk from cooling failures or<br />
overheating of the coolant. Moreover,<br />
the use of thermocouples or thermistors<br />
is recommended on motors with<br />
a very high number of poles where in<br />
the case of a phase failure, the current<br />
in the remaining phases will increase<br />
but slightly.
01.01<br />
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Hazardous duty<br />
Hazardous-duty motors, whether of<br />
the "Ex(e)" increased safety or "(Ex)d"<br />
explosion-proof type, are supplied for<br />
400 V three-phase a.c. operation and<br />
installed for ignition class G1 to G4.<br />
Please enquire about "(Ex)d" type<br />
availability. Such "explosion-proof"<br />
(pressure-containing) motors are required<br />
in rooms and operating facilities<br />
in which explosive atmospheres<br />
are frequently present (refer to VDE<br />
0165). Whether a location or plant belongs<br />
to a hazardous-duty category<br />
according to this regulation must be<br />
decided by the relevant supervisory<br />
body, e.g., a trade supervisory authority<br />
or technical inspectorate. These<br />
authorities will also determine the applicable<br />
protection class. (Conditions<br />
may vary from country to country)<br />
Where hazardous-duty motors are<br />
specified, the associated fans must<br />
L1<br />
L2<br />
L3 N<br />
PE<br />
Terminal<br />
box<br />
F1 F3<br />
K1<br />
F2<br />
X1<br />
M2<br />
1 3 5<br />
2 4 6<br />
2 4 6<br />
1 2 3<br />
U1<br />
V1 W1 U2 V2<br />
U1 V1 W1<br />
U2 V2 W2<br />
M2 fan motor<br />
(230/400 V �/Y)<br />
Contactor control circuit with overcurrent<br />
protection for one-speed<br />
motor with direct on-line starting<br />
PE<br />
W2 PE<br />
AXIAL FLOW FANS<br />
ELECTRICAL NOTES<br />
GENERAL / CIRCUIT DIAGRAMS<br />
be of a spark-suppressed type. For<br />
this application a special slipring is<br />
available for installation between the<br />
impeller and the casing.<br />
Operation<br />
Direct on-line starting<br />
The breakaway torque may reach 150<br />
– 300% of the nominal torque, depending<br />
on output and number of poles.<br />
Starting currents may rise to between<br />
4 and 6 times the rated current value.<br />
Star-delta starting<br />
Here the starting current and torque<br />
are only about one-third of what they<br />
would be with direct on-line starting.<br />
The motor should be close to its nominal<br />
rpm before the changeover is<br />
made.<br />
With high-powered motors, please<br />
consult with us on fan starting modes<br />
and start-up times.<br />
F2 F2<br />
S1<br />
S2 K1<br />
K1 H1 H2<br />
Run Fault<br />
028<br />
IMPORTANT!<br />
All axial-flow fans are equipped with<br />
IEC standard motors sourced from<br />
various quality-brand manufacturers.<br />
These motors do NOT feature thermocouple<br />
or thermistor protection<br />
systems. They must therefore be operated<br />
with an overcurrent protection<br />
device according to VDE 0660.<br />
Please enquire about current consumption<br />
details. For guidance, refer<br />
to the motor manufacturers' catalogues.<br />
L1<br />
L2<br />
L3<br />
N<br />
PE<br />
NO1
01.01<br />
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
L1<br />
L2<br />
L3 N<br />
PE<br />
Contactor control circuit for a twospeed<br />
motor with Dahlander polechanging<br />
winding and overcurrent<br />
protection<br />
L1<br />
L2<br />
L3 N<br />
PE<br />
K3<br />
Maintenance<br />
switch<br />
1 3 5<br />
2 4 6<br />
Terminal box<br />
K1<br />
F2<br />
Q1<br />
F1<br />
Contactor control circuit for a twospeed<br />
motor with separate windings<br />
with overcurrent protection<br />
AXIAL FLOW FANS<br />
ELECTRICAL NOTES<br />
CIRCUIT DIAGRAMS<br />
F1 F4<br />
1 3 5<br />
K1<br />
2 4 6<br />
F2<br />
2 4 6<br />
X1 1 2 3 4 5 6 PE<br />
1U<br />
K2<br />
1 3 5<br />
2 4 6<br />
F3<br />
2 4 6<br />
1U 1W 2U 2V<br />
1U 1U 1W<br />
2U 2U 2W<br />
M1 fan motor<br />
(400 V Y/YY)<br />
PE<br />
X1<br />
1 2 3 4 5 6<br />
M1<br />
2 4 6<br />
L1 L2 L3<br />
F3<br />
1 3 5 K2<br />
2 4 6<br />
T1 T2 T3<br />
1U 1V 1W<br />
2U 2V 2W<br />
M1 fan motor<br />
(400 V)<br />
F4<br />
PE<br />
1 3 5<br />
2 4 6<br />
2 4 6<br />
L4 L5 L6<br />
T4 T5 T6<br />
2W PE<br />
51 63<br />
52 64<br />
PE<br />
PE<br />
F5<br />
F2 F2 F3<br />
F3<br />
S1<br />
S2<br />
K2 K3 K1<br />
K3<br />
K1 S3 K2<br />
K1 H1 K2 K3 H2 H3 H4<br />
Run<br />
Stage I<br />
Run<br />
Stage II<br />
Fault<br />
Stage I<br />
F2 F2 F4<br />
F4<br />
S1<br />
S2<br />
K2<br />
K1 S3 K2<br />
K1<br />
K1 H1 K2 H2 H3 H4<br />
Run<br />
Stage I<br />
Run<br />
Stage II<br />
Fault<br />
Stage I<br />
029<br />
L1<br />
L2<br />
L3<br />
N<br />
PE<br />
NO1<br />
Fault<br />
Stage II<br />
L1<br />
L2<br />
L3<br />
N<br />
PE<br />
NO1<br />
Fault<br />
Stage II
01.01<br />
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
L1<br />
L2<br />
L3 N<br />
PE<br />
Q1<br />
Maintenance<br />
switch<br />
Contactor control circuit for a singlespeed<br />
motor with thermocouple. Auxiliary<br />
contacts are provided to open<br />
L1<br />
L2<br />
L3 N<br />
PE<br />
Contactor control circuit for a singlespeed<br />
motor with overcurrent protection<br />
for star delta starting<br />
AXIAL FLOW FANS<br />
ELECTRICAL NOTES<br />
CIRCUIT DIAGRAMS<br />
F1 F3<br />
K2<br />
X1<br />
M1<br />
F1<br />
K2<br />
F2<br />
Q1<br />
Maintenance<br />
switch<br />
1<br />
X1 1<br />
1 3 5<br />
2 4 6<br />
2 3 4 5 PE<br />
S1<br />
6 6 7 8 PE<br />
L1 L2 L3 13 43 31<br />
T1 T2 T3 Terminal 14 44 32<br />
U1 V1 W1<br />
W2 U2 V2<br />
M1<br />
fan rmotor<br />
(400/690 V �/Y)<br />
1 3 5<br />
2 4 6<br />
2 4 6<br />
M1<br />
F2<br />
2 3 4 5 6 PE<br />
L1 L2 L3 L4 L5 L6 13 21<br />
T1 T2 T3 T4 T5 T6 14 22<br />
U1 V1 W1<br />
M1 P1<br />
U2 V2 W2<br />
M1<br />
fan motor<br />
(400/690 V �/Y)<br />
K3<br />
1 3 5<br />
2 4 6<br />
51 63<br />
52 64<br />
K1<br />
1 3 5<br />
2 4 6<br />
PE<br />
PE<br />
S2<br />
K1<br />
B1<br />
K1 H1 K2<br />
a damper when the fan motor is running<br />
and close it when the motor is<br />
stationary. In addition, the system is<br />
F3<br />
S1<br />
K1 K2<br />
Contactmaking<br />
device<br />
M2<br />
Damper actuating motor<br />
030<br />
L1<br />
L2<br />
L3<br />
N<br />
PE<br />
equipped for connection of a contactmaking<br />
device for switching on and<br />
off the fan motor.<br />
F2 F2<br />
S2<br />
K4<br />
K3 K1<br />
K1<br />
K1 K4 K3 K2 H1 H2<br />
Star<br />
contactor<br />
Delta<br />
contactor<br />
K2<br />
Mains<br />
contactor<br />
Run Fault<br />
L1<br />
L2<br />
L3<br />
N<br />
PE<br />
N
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � p t1 [Pa]<br />
2000<br />
1800<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
40<br />
M-D Type<br />
AXO series – without guide vanes<br />
– direct drive<br />
– airflow direction “D“<br />
1120<br />
Nominal<br />
speed<br />
1500 rpm<br />
8/315<br />
8/400<br />
Volume flow [m 3 /h]<br />
8/315<br />
AXIAL FLOW FANS AXO SERIES<br />
DIRECT DRIVE<br />
PRE-SELECTION DIAGRAMS<br />
RANGE OF APPLICATION / USE<br />
Nominal speed 3000 rpm<br />
5/500<br />
8/400<br />
9/630<br />
5/630<br />
5/500<br />
9/630<br />
9/800<br />
9/500<br />
9/800<br />
9/630<br />
5/630<br />
9/1000<br />
Sizes / Nominal speeds<br />
Nominal speed 750 rpm<br />
6 sizes: 800/1000/1120/<br />
1250/1400/1600 dia.<br />
Nominal speed 1000 rpm<br />
7 sizes: 630/800/1000/1120/<br />
1250/1400/1600 dia.<br />
Nominal speed 1500 rpm<br />
9 sizes 315/400/500/630/800/<br />
1000/1120/1400/1600 dia.<br />
Nominal speed 3000 rpm<br />
3 sizes 315/400/500 dia.<br />
9/800<br />
Number of blades<br />
4, 5, 8, 9, 12 or 16 blades (refer to<br />
the above pre-selection diagram and<br />
to the characteristic curves on page<br />
044 - 078).<br />
Range of Application<br />
For small to large volume flows<br />
against low pressures.<br />
V · = approx. 900 m 3 /h<br />
to 224 000 m 3 /h<br />
� pt = approx. 30 Pa to 1800 Pa<br />
9/1000<br />
12/1120<br />
8/1250<br />
12/1000<br />
12/1120<br />
Nominal speed<br />
750 rpm<br />
Nominal<br />
speed<br />
1000 rpm<br />
12/1120<br />
8/1600<br />
10/1400<br />
8/1600<br />
031<br />
Density 1,2 kg/m 3<br />
Temperature: 20C<br />
1250<br />
1400<br />
1600<br />
1800<br />
2000<br />
2240<br />
2500<br />
2800<br />
3150<br />
3550<br />
4000<br />
4500<br />
5000<br />
5600<br />
6300<br />
7100<br />
8000<br />
9000<br />
10000<br />
11200<br />
12500<br />
14000<br />
16000<br />
18000<br />
20000<br />
22400<br />
25000<br />
28000<br />
31500<br />
35500<br />
40000<br />
45000<br />
50000<br />
56000<br />
63000<br />
71000<br />
80000<br />
90000<br />
100000<br />
112000<br />
125000<br />
140000<br />
160000<br />
180000<br />
200000<br />
224000<br />
Use<br />
Preferably in applications in which<br />
the system resistance lies on the<br />
inlet side, e.g., straightforward air<br />
extraction or venting systems, process<br />
equipment, cooling towers,<br />
condensers, greenhouses, livestock<br />
stables, and in dryer exhaust service.<br />
For systems with outlet side resistances,<br />
these fans should be used<br />
with caution specifically if such resistances<br />
are encountered immediately<br />
downstream of the fan. The swirl<br />
may cause resistances to increase to<br />
many times their calculated value.<br />
Please consult with our engineering<br />
experts in such cases.<br />
For characteristic curves<br />
refer to pages 044 – 078
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase pt [Pa]<br />
3150<br />
2500<br />
2000<br />
1600<br />
1250<br />
1000<br />
800<br />
630<br />
500<br />
400<br />
315<br />
250<br />
200<br />
160<br />
125<br />
100<br />
80<br />
63<br />
50<br />
40<br />
M-D Type<br />
AXN series – with outlet guide vanes<br />
– direct-drive<br />
– 0.56 hub ratio<br />
– 12 impeller blades<br />
– airflow direction "D"<br />
500<br />
630<br />
800<br />
315<br />
1000<br />
250<br />
1250<br />
355<br />
1600<br />
Volume flow V · [m 3 /h]<br />
400<br />
500<br />
2000<br />
280<br />
Sizes / Nominal Speeds<br />
Nominal speed 750 rpm<br />
11 Sizes 630 to 2000 dia.<br />
Nominal speed 1000 rpm<br />
11 Sizes 500 to 1600 dia.<br />
Nominal speed 1500 rpm<br />
12 Sizes 315 to 1250 dia.<br />
Nominal speed 3000min -1<br />
7 Sizes 250 bis 500 dia.<br />
2500<br />
AXIAL FLOW FANS AXN SERIES<br />
DIRECT DRIVE<br />
PRE-SELECTION DIAGRAMS<br />
RANGE OF APPLICATION / USE<br />
450<br />
3150<br />
315<br />
560<br />
Size 630<br />
4000<br />
630<br />
5000<br />
355<br />
500<br />
6300<br />
Nominal speed<br />
3000 rpm<br />
8000<br />
400<br />
560<br />
10000<br />
450<br />
710<br />
630<br />
710<br />
12500<br />
16000<br />
500<br />
710<br />
900<br />
800<br />
800<br />
20000<br />
25000<br />
800<br />
900<br />
Number of blades<br />
Standard fans: 12 blades<br />
(for characteristic curves refer to the<br />
catalogue)<br />
For impellers with 9, 8, 6 or 4 blades:<br />
please enquire about characteristics<br />
and sizing.<br />
Hub ratio<br />
Standard fans 0.56<br />
(for characteristic curves refer to the<br />
catalogue)<br />
Special design: 0.63<br />
(Please enquire about characteristics<br />
and sizing)<br />
Nominal speed<br />
1500 rpm<br />
1000<br />
31500<br />
900<br />
1000<br />
40000<br />
1120<br />
50000<br />
1000<br />
1120<br />
63000<br />
1250<br />
1120 1250<br />
1250<br />
1400<br />
1400<br />
Nominal speed<br />
750 rpm<br />
80000<br />
100000<br />
125000<br />
1600<br />
1600<br />
1800<br />
032<br />
Nominal speed<br />
1000 rpm<br />
2000<br />
Density: 1,2 kg/m 3<br />
Temperature: 20 °C<br />
160000<br />
200000<br />
250000<br />
315000<br />
400000<br />
Range of Application<br />
From small volume flows against low<br />
pressures to very large volume flows<br />
against high pressures.<br />
V · = approx. 600 to 400 000 m 3 /h<br />
� pt = approx. 50 Pa bis 1800 Pa<br />
Use<br />
Ventilation systems, air conditioning,<br />
air recirculation and air exhaust solutions,<br />
process equipment, dryer construction,<br />
ship ventilation systems.<br />
For characteristic curves<br />
refer to pages 089 - 131
01.01<br />
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase pt [Pa]<br />
5000<br />
4000<br />
3150<br />
2500<br />
2000<br />
1600<br />
1250<br />
1000<br />
800<br />
630<br />
500<br />
400<br />
315<br />
250<br />
200<br />
160<br />
125<br />
100<br />
80<br />
R1 Type<br />
R2 Type<br />
AXN series – with outlet guide vanes<br />
– belt-drive<br />
– 12 impeller blades<br />
– airflow direction "D"<br />
AXN 12/56/400<br />
AXN 12/56/450<br />
AXN 12/56/500<br />
Volume flow V · [m 3 /h]<br />
AXN 12/56/560<br />
AXIAL FLOW FANS AXN SERIES<br />
BELT DRIVE<br />
PRE-SELECTION DIAGRAMS<br />
RANGE OF APPLICATION / USE<br />
AXN 12/56/630<br />
AXN 12/56/710<br />
Sizes / Hub ratio<br />
With hub ratio 0.56<br />
15 Sizes 400 to 2000 dia.<br />
With hub ratio 0.50<br />
2 Sizes 2000 and 2240 dia.<br />
With hub ratio 0.45<br />
1 Size 2500 dia.<br />
AXN 12/56/800<br />
AXN 12/56/900<br />
AXN 12/56/1000<br />
AXN 12/56/1120<br />
AXN 12/56/1250<br />
Number of blades<br />
12 impeller blades on all versions<br />
(for characteristic curves refer to the<br />
catalogue)<br />
An optimum adjustment to the required<br />
operating point is achieved via<br />
the fan speed by changing the belt<br />
transmission ratio.<br />
Range of Application<br />
From small volume flows against low<br />
pressures to very large volume flows<br />
against high pressures.<br />
V · = approx. 4000 to 560 000 m 3 /h<br />
� pt = approx. 80 Pa to 1800 Pa<br />
AXN 12/56/1400<br />
AXN 12/56/1600<br />
AXN 12/50/2000<br />
AXN 12/56/1800<br />
AXN 12/50/2240<br />
AXN 12/56/2000<br />
AXN 12/45/2500<br />
5600<br />
6300<br />
7100<br />
8000<br />
9000<br />
10000<br />
11200<br />
12500<br />
14000<br />
16000<br />
18000<br />
20000<br />
22400<br />
25000<br />
28000<br />
31500<br />
35500<br />
40000<br />
45000<br />
50000<br />
56000<br />
63000<br />
71000<br />
80000<br />
90000<br />
100000<br />
112000<br />
125000<br />
140000<br />
160000<br />
180000<br />
200000<br />
224000<br />
250000<br />
280000<br />
315000<br />
355000<br />
400000<br />
450000<br />
500000<br />
560000<br />
Die Leistungsgrenzen der<br />
Bauformen R1 und R2 bitte den<br />
Kennlinienblättern entnehmen.<br />
033<br />
Density: 1.2 kg/m3 Temperature: 20 °C<br />
Use<br />
Ventilation systems, air conditioning,<br />
large air supply and extraction centers.<br />
In these environments these fans are<br />
particularly suitable for installation in<br />
equipment, conventional air conditioning<br />
centers, or sandwich-type<br />
center configurations.<br />
For characteristic curves<br />
refer to pages 139 - 155
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Our test rig for axial-flow fans conforms to DIN 24 163<br />
for volume and pressure measurements and DIN 45 635,<br />
Part 9 (draft) for sound measurements.<br />
Extension<br />
L = 2.5 D<br />
Calibrated<br />
motor<br />
Specimen<br />
<strong>Axial</strong>-flow fan<br />
Measuring<br />
duct<br />
Antidrum<br />
compound<br />
Air handling test station with chamber rig<br />
and partial view of the fan measuring duct.<br />
AXIAL FLOW FANS<br />
IN-HOUSE RESEARCH – RELIABLE RESULTS<br />
MEASURING CONFIGURATION<br />
Sound measuring duct<br />
Friedrichs<br />
probe<br />
1<br />
Air-tight<br />
hatch<br />
View of the measuring center of our test<br />
station. An array of high-precision instruments<br />
are needed for the measurements,<br />
e.g., a Betz pressure gauge ➀, a calibra-<br />
1<br />
1<br />
Low-reflection air<br />
duct connection as<br />
per DIN 45635, Part 9<br />
2<br />
3<br />
isolated Damping chamber,<br />
calibrated<br />
4<br />
034<br />
Nozzles<br />
ting unit for the pressure measuring station<br />
➁, a frequency analyzer for collecting<br />
acoustic data ➂, a measured data<br />
acquisition computer ➃, etc.<br />
Measurement 1<br />
<strong>Axial</strong>-flow fan, direct discharge<br />
The dynamic pressure (pd) is<br />
related to the annular cross<br />
section (A1).<br />
Application: direct discharge<br />
into a large room.<br />
(The dynamic pressure pdR is<br />
fully considered as loss. Use<br />
red characteristic curves.)<br />
Measurement 2<br />
<strong>Axial</strong>-flow fan with outlet-side<br />
equalizing duct. The dynamic<br />
pressure (od) is related to the<br />
full circular cross-section (A2)<br />
(The impact loss is reflected<br />
in the characteristic curve.<br />
Use black characteristic curves.)<br />
Measurement 3<br />
<strong>Axial</strong>-flow fan with outlet diffuser.<br />
The dynamic pressure<br />
(pd) is related to the annular<br />
cross-section.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Important design notice:<br />
<strong>Axial</strong>-flow fans have a pronounced<br />
stall range starting on the left of the<br />
respective curve end. Due to the risk<br />
of fatigue failure, an axial-flow fan<br />
must not be operated in stall mode. It<br />
is therefore important when sizing<br />
these fans to allow for an appropriate<br />
safety margin around the stall point.<br />
The operating point should be located<br />
on the right-hand (steep) side of<br />
the curve. A pressure margin of approx.<br />
15% from the stall point is recommended.<br />
Stall<br />
margin<br />
Stall<br />
point<br />
Fan characteristic<br />
Operating point<br />
In selecting fans and their control systems,<br />
care should be taken to ensure<br />
that all operating points of the envisaged<br />
control range lie within the stable<br />
area of the fan characteristic.<br />
Flow direction<br />
Direct-driven fans are available with<br />
the airflow direction "D" (motor in<br />
outlet) or "S" (motor in inlet). The<br />
catalogue shows the characteristic<br />
curves for airflow direction "D" units.<br />
For "S" type fans, a correction of the<br />
fan characteristic must be applied as<br />
follows:<br />
Volume flow + 5 %<br />
Total pressure increase + 10 %<br />
In addition, 5% should be deducted<br />
from the efficiency value.<br />
Belt-driven fans are available with airflow<br />
direction "D" only.<br />
If - for whatever reason - a belt guard<br />
is to be provided inside the fan, an<br />
output reduction must be expected.<br />
The impellers are not designed for reversible<br />
or contra-rotating operation.<br />
AXIAL FLOW FANS<br />
WITH ADJUSTABLE BLADES AT REST<br />
SIZING INFORMATION<br />
Air inlet/outlet<br />
Our characteristic curves are based<br />
on the assumption that a uniformly<br />
swirl-free velocity distribution prevails<br />
at the fan inlet. It may therefore be necessary<br />
to install a bellmouth inlet in<br />
the case of free intake configurations,<br />
or to fit appropriate guide panels if the<br />
fan operates immediately downstream<br />
of a duct elbow.<br />
Antivibration mounts<br />
Size 224 – 900 fans operating at<br />
1000+ rpm and size 1000 – 2000 fans<br />
with speeds exceeding 750 rpm can<br />
be fitted on rubber antivibration<br />
mounts.<br />
Determining motor output<br />
We recommend that the calculated<br />
shaft horsepower (PW) should be increased<br />
by the following percentages:<br />
Direct-driven fans +5% to 10%<br />
Belt-driven fans +10% to 20%<br />
Motor terminal box for AXO types<br />
All fans of this type (sizes 315 – 1000)<br />
are supplied with an exterior terminal<br />
box fitted on the casing and wired to<br />
the motor terminal box.<br />
Motor terminal box for AXN types<br />
Fans up to size 1250 are supplied with<br />
an exterior terminal box fitted on the<br />
casing and wired to the motor terminal<br />
box.<br />
Important notes:<br />
Direct-driven fans are available<br />
only with the motor output ratings<br />
indicated in our price lists.<br />
(Please inquire for special motors).<br />
The max. motor outputs for beltdrive<br />
fans are stated on the characteristic<br />
curve sheets on page 139 –<br />
155.<br />
For maximum acceptable motor<br />
sizes please refer to the dimensional<br />
diagrams on pages 007 – 011.<br />
035<br />
Acoustics<br />
All acoustic performance data are<br />
given in the characteristic curve<br />
sheets and on the "Acoustic Data"<br />
pages. The information supplied is<br />
valid for the stated rotational speeds.<br />
Acoustic data for other rpm levels<br />
can be derived by approximation<br />
using the following formulas:<br />
For lower rpm:<br />
L 1 = L 2 – 45 [log ( n2 )]<br />
n1<br />
For higher rpm:<br />
L 2 = L 1 + 45 [log ( n2 )]<br />
n1<br />
To correct for a greater distance:<br />
Distance in m<br />
Decrease in sound pressure level (dB)<br />
The acoustic emissions of multiple<br />
axial-flow fans operating at the same<br />
sound volume can be determined<br />
using the following table:<br />
Number of units<br />
Increase in sound level (dB)<br />
If two not equally loud axial-flow fans<br />
are operated simultaneously, the following<br />
correction values should be<br />
added to the higher acoustic level:<br />
Level difference [dB]<br />
Value to be added [dB]<br />
Fans with two or more speeds<br />
In the characteristic curves appearing<br />
below, the effect of the<br />
Reynolds number has been taken<br />
into account. As a result, the known<br />
laws of proportionality are not applicable<br />
to all fan sizes, specifically at<br />
small diameters and low speeds.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
The ideal mounting configuration<br />
corresponds to that of the test airflow<br />
duct, with inlet and outlet tube diameters<br />
of 2.5 x D (D = fan diameter).<br />
Fig. 1<br />
200<br />
Flexible duct connectors upstream<br />
and downstream of the fan must be fitted<br />
carefully with zero offset, taking<br />
into account the installed length. Failure<br />
to observe this rule will result in<br />
performance loss and increased acoustic<br />
emissions. Flexible connectors are<br />
not intended as “elastic fit“ adapters<br />
compensating for installation inaccuracies!<br />
Where dampers must be fitted in airflows<br />
arriving vertically from below<br />
(e.g., through a ceiling or inlet duct), an<br />
opposed-blade damper type should be<br />
used to ensure an appropriate approach<br />
flow onto downstream deflector<br />
or baffle elements.<br />
The flexible duct connector (two nominal<br />
sizes > nominal fan size) ensures<br />
an additional improvement in incoming<br />
flow conditions and superior acoustic<br />
performance.<br />
AXIAL FLOW FANS<br />
INSTALLATION EXAMPLES<br />
2,5 x D 2,5 x D<br />
On free inlet fans, the use of an optimized<br />
bellmouth is mandatory. Failure to<br />
install this would result in severely degraded<br />
fan performance and increased<br />
noise levels.<br />
To satisfy accident prevention rules, a<br />
wire guard must be fitted to the front of<br />
the bellmouth.<br />
Fig. 2/2.1/2.2 Fig. 3/3.1 Fig. 4/4.1<br />
Baffles<br />
Opposedbladedamper<br />
b<br />
a<br />
b = 0,6 x a<br />
at least five, ideally<br />
more (e.g., 8 baffles)<br />
With horizontal approach flows from a<br />
larger duct or inlet chamber, an oversized<br />
flexible connector (two nominal<br />
sizes > nominal fan size) in conjunction<br />
with the bellmouth will greatly improve<br />
incoming flow conditions and<br />
noise output.<br />
An approach flow situation as shown<br />
in Fig. 6 will result in a greatly impaired<br />
fan performance.<br />
Fig. 5/5.1 Fig. 6/6.1 Fig. 7/7.1<br />
036<br />
Connections of the above type are absolutely<br />
unacceptable in practice.<br />
2,5 x D<br />
In special cases, i.e., where no alternative<br />
is feasible, an adapter cone and<br />
2.5 D tube section (D = fan diameter)<br />
must be fitted as shown.<br />
Installation of an axial-flow fan directly<br />
downstream of a curved duct section<br />
will give rise to substantial performance<br />
losses and noise increase.<br />
If a 2.5 x D inlet flow section cannot be<br />
fitted, baffles should be used (for configuration<br />
and sizes refer to Fig. 5.1)
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
In a free-outlet configuration, the dynamic<br />
pressure acting on the fan’s annular<br />
surface area (fan surface minus<br />
hub surface) must be taken into account<br />
as impact loss.<br />
Fig. 8/8.1/8.2<br />
To avoid high impact loss, turbulence<br />
effects and excessive noise, downstream<br />
splitter attenuators should be<br />
connected via a diffuser with internal<br />
core and an interposed pressure<br />
chamber. In systems with large cross<br />
sections, the pressure chamber may<br />
be additionally provided<br />
Curved leading ends<br />
Baffle screen<br />
Diffuser with<br />
core<br />
with a built-in baffle screen (perforated<br />
metal panel). This recommendation<br />
also applies to filters, heaters, etc. The<br />
splitters should have curved leading<br />
ends.<br />
AXIAL FLOW FANS<br />
INSTALLATION EXAMPLES<br />
Maximum impact loss 50% reduced impact loss 70% reduced impact loss<br />
High impact loss<br />
Fig. 9/9.1<br />
min.<br />
0,5xD<br />
For in-chamber installation specified<br />
minimum distance must be observed.<br />
If multiple fans are mounted next to<br />
each other, the distance between their<br />
bellmouths must be at least 0.5 D.<br />
Free outlet Free outlet<br />
0,5 x D<br />
On a free outlet system with 2.5 x D outlet<br />
duct, the entire surface area as determined<br />
from the nominal fan size may be<br />
used for the impact loss calculation (rectified<br />
flow).<br />
In-chamber installation<br />
The same applies by<br />
analogy for installation<br />
in tube or channel<br />
ducts.<br />
In practice, fans are often mounted in<br />
such cramped conditions that proper<br />
maintenance or repairs are impossible<br />
or extremely costly to carry out. Fans<br />
are machines which comprise wearing<br />
parts. It is therefore important to provide<br />
adequate free space around the unit for<br />
maintenance or repair access. On roofs<br />
(especially warm roofs), the availability<br />
Fig. 11<br />
Fig. 10 Fig. 12<br />
Plenum inlet<br />
chamber<br />
Vortex flow effects<br />
are often encountered<br />
in configurations<br />
of this<br />
type. The use of<br />
an anti-vortex baffle<br />
is recommended.<br />
2,5 x D<br />
In large inlet chambers with multible air<br />
streams, vortex effects may impair the<br />
airflow at the fan inlet. Performance losses<br />
are an inevitable result. In this type<br />
of operating situation, the recommended<br />
anti-vortex baffle should either be<br />
fitted from the start or planned in such a<br />
way it can be installed later.<br />
Diffuser with core<br />
037<br />
Free outlet<br />
Diffusers can reduce impact loss by<br />
about 70% when compared to the configuration<br />
shown in Fig. 8.<br />
0,5 x nominal fan size<br />
Bafflefront<br />
view Baffle -<br />
side view<br />
1 x nominal fan size<br />
+ at least 1 m<br />
of sufficiently strong support areas is<br />
important. It should be possible to erect<br />
scaffolding above and around the fans<br />
for installation and maintenance.<br />
0,5 x D<br />
Please also observe other fan technology<br />
fundamentals as described in the<br />
relevant academic and trade literature<br />
(e.g., <strong>TLT</strong> Fan Primer, published by Promoter<br />
Verlag, Karlsruhe). Our staff will<br />
be glad to answer your questions on<br />
this subject.
Am Weinberg Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Hersfeld/Germany<br />
Phone: Tel.: +49.6621.950-0 +49.6621.950-0 · · Fax: +49.6621.950-100<br />
Instruction for using the characteristic<br />
curve sheet:<br />
Given:<br />
Volume flow V · = 14 m3/s Totel pressure<br />
increase �pt = 1000 Pa<br />
(ca. 100 kp/m2) Density = 1.2 kg/m 3<br />
Temperature t = 20 °C<br />
Speed n = 1450 rpm<br />
Sought:<br />
Fan size, power input requirement,<br />
overall acoustic power level<br />
Selected:<br />
<strong>Axial</strong>-flow fan<br />
Typ AXN 12/56/900/M-D<br />
(direct-drive)<br />
Specifications:<br />
Peripheral speed u = 67 m/s<br />
Flow velocity c = 22.4 m/s<br />
Efficiency � = 76%<br />
Shaft power<br />
input:<br />
�<br />
·<br />
V ·�pt 50000 · 1000<br />
P w = = =18.27 kW<br />
� · 1000 · 3600 0.76 · 1000 · 3600<br />
Recommended<br />
motor output P M = 22 kW<br />
Total acoustic<br />
power level L W = 103.5 dB<br />
All fans are available only with the<br />
motor outputs stated in our price<br />
lists.<br />
AXIAL FLOW FANS – AXN SERIES<br />
DIRECT DRIVE<br />
SELECTION EXAMPLE<br />
(FAN OUTLET INTO DUCT)<br />
TURBO LUFTTECHNIK GMBH<br />
Business Unit Standard Fans<br />
BABCOCK BSH System<br />
Am Postfach Weinberg 1234 68 · · 36222 D-36251 Bad Bad Hersfeld/Germany<br />
Tel.: + +49.6621.950-0 49.6621.950-0 · · Fax: +49.6621.950-100<br />
+ 49.6621.950-100<br />
Key to the type designations:<br />
AXN 12 / 56 / 900 / M – D<br />
2D08026<br />
Airflow direction D, motor in outlet<br />
Type M (directly coupled motor)<br />
Size (nominal design size)<br />
Hub ratio<br />
(outer impeller dia. / hub dia.)<br />
Impeller with 12 blades<br />
With outlet guide vanes<br />
<strong>Axial</strong>-flow fan<br />
038<br />
Blade pitch angle
01.01<br />
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Instruction for using the characteristic<br />
curve sheets:<br />
Given:<br />
Volume flow V · = 40.000 m 3/h<br />
Total pressure<br />
increase �pt = 900 Pa<br />
(ca. 90 kp/m 2)<br />
Density = 1.2 kg/m 3<br />
Temperature t = 20 °C<br />
Sought:<br />
Fan size, rpm, power input requirement,<br />
etc.<br />
Selected:<br />
<strong>Axial</strong>-flow fan<br />
Typ AXN 12/56/900 R1<br />
(belt-driven)<br />
Specifications:<br />
Fan speed n = 1250 rpm<br />
Peripheral speed u = 59 m/s<br />
Flow velocity c = 18 m/s<br />
Efficiency � = 82%<br />
Shaft power<br />
input requirement P W = 12,19 kW<br />
Recommended<br />
motor output P M = 15 kW<br />
Total acoustic<br />
power level L W Vent = 102 dB<br />
�<br />
Belt-drive fans are available only<br />
with the maximum motor outputs<br />
stated on the characteristic curve<br />
sheets.<br />
AXIAL FLOW FANS – AXN SERIES<br />
BELT DRIVE<br />
SELECTION EXAMPLE<br />
(FAN OUTLET INTO DUCT)<br />
TURBO LUFTTECHNIK GMBH<br />
Business Unit Standard Fans<br />
BABCOCK BSH System<br />
Postfach Am Weinberg 1234 68 · · 36222 D-36251 Bad Bad Hersfeld/Germany<br />
Tel.: Tel.: + +49.6621.950-0 49.6621.950-0 · Fax: +49.6621.950-100<br />
+ 49.6621.950-100<br />
Key to the type designations<br />
AXN 12 / 56 / 900 R1<br />
2D08027<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/900/R1-R2<br />
Type R1, belt-driven<br />
Size (nominal design size)<br />
Hub ratio<br />
(outer impeller dia. / hub dia.)<br />
Impeller with 12 blades<br />
With outlet guide vanes<br />
<strong>Axial</strong>-flow fan<br />
039
AXO series (without guide vanes)<br />
– Technical Lists pages 042 - 043<br />
– Characteristic curves pages 044 - 078<br />
– Specification pages 079 - 080<br />
AXN series (with guide vanes)<br />
– Technical Lists pages 083 - 088<br />
– Characteristic curves<br />
(direct drive) pages 089 - 131<br />
– Specification pages 132 - 135<br />
– Characteristic curves<br />
(belt drive) pages 139 - 155<br />
– Specification pages 156 - 159
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal<br />
speed<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
Size Type<br />
[rpm]<br />
�<br />
AXIAL FLOW FANS<br />
TECHNICAL LISTS (AVAILABLE MODELS)<br />
AXO SERIES<br />
Number<br />
of<br />
blades<br />
315 1500 0,25 0,78 71 B3 8<br />
3000 0,37 0,9 71 B3 8<br />
0,55 1,4 71 B3 8<br />
0,75 1,75 80 B3 8<br />
1,1 2,55 80 B3 8<br />
1500/750 0,2/0,05 0,71/0,3 71 B3 8<br />
3000/1500 0,3/0,08 0,95/0,28 71 B3 8<br />
0,48/0,12 1,21/0,34 71 B3 8<br />
0,7/0,18 1,75/0,47 80 B3 8<br />
0,9/0,25 2,19/0,63 80 B3 8<br />
400 1000 0,18 0,88 71 B3 8<br />
1500 0,25 0,78 71 B3 8<br />
0,37 1,06 71 B3 8<br />
3000 1,1 2,55 80 B3 8<br />
1,5 3,3 90 B3 8<br />
2,2 4,5 90 B3 8<br />
3,0 6,0 100 B3 8<br />
1500/750 0,3/0,075 1,08/0,44 71 B3 8<br />
1500/1000 0,4/0,12 1,25/0,52 80 B3 8<br />
3000/1500 0,9/0,25 2,19/0,63 80 B3 8<br />
1,5/0,37 3,45/0,87 90 B3 8<br />
2,0/0,5 4,45/1,12 90 B3 8<br />
2,8/0,7 6,1/1,55 100 B3 8<br />
3,6/0,9 7,7/2,0 100 B3 8<br />
500 1000 0,37 1,22 80 B3 (5) 9<br />
0,55 1,73 80 B3 (5) 9<br />
1500 0,55 1,6 80 B3 (5) 9<br />
0,75 2,1 80 B3 (5) 9<br />
1,1 2,62 90 B3 (5) 9<br />
1,5 3,4 90 B3 (5) 9<br />
3000 3,0 6,0 100 B3 (5) 9<br />
4,0 7,5 112 B3 (5) 9<br />
5,5 11 132 B3 9<br />
7,5 14 132 B3 9<br />
11 20,5 132 B3 9<br />
1000/500 0,48/0,08 1,6/0,58 90 B3 (5) 9<br />
1500/750 0,5/0,12 1,31/0,49 80 B3 (5) 9<br />
0,7/0,18 1,79/0,7 80 B3 (5) 9<br />
1,0/0,25 2,55/0,97 90 B3 (5) 9<br />
1500/1000 0,4/0,12 1,25/0,52 80 B3 (5) 9<br />
0,55/0,16 1,55/0,63 80 B3 (5) 9<br />
0,75/0,25 1,9/0,87 90 B3 (5) 9<br />
1,1/0,37 2,7/1,25 90 B3 (5) 9<br />
3000/1500 4,8/1,2 10,2/2,5 112 B3 (5) 9<br />
8,2/2,2 17,5/4,5 132 B3 (5) 9<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal<br />
speed<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
Size Type<br />
[rpm] �<br />
� Nominal current = appr. values for 400 V motors (depending on brand)<br />
042<br />
Number<br />
of<br />
blades<br />
630 750 0,55 2,04 90 B3 (5) 9<br />
1000 0,75 2,43 90 B3 (5) 9<br />
1,1 3,15 90 B3 (5) 9<br />
1500 1,1 2,62 90 B3 (5) 9<br />
1,5 3,4 90 B3 (5) 9<br />
2,2 5,15 100 B3 (5) 9<br />
3,0 6,7 100 B3 (5) 9<br />
4,0 8,8 112 B3 (5) 9<br />
3000 5,5 11 112 B3 5<br />
7,5 14,5 112 B3 5<br />
8,25 15,5 112 B3 5<br />
11 20,5 132 B3 9<br />
15 27 132 B3 9<br />
1000/500 0,48/0,08 1,6/0,58 90 B3 (5) 9<br />
0,8/0,15 2,3/0,9 90 B3 (5) 9<br />
1500/750 1,0/0,25 2,55/0,97 90 B3 (5) 9<br />
1,5/0,37 3,7/1,33 90 B3 (5) 9<br />
2,5/0,65 5,5/2,38 100 B3 (5) 9<br />
1500/1000 1,1/0,37 2,7/1,25 90 B3 (5) 9<br />
1,5/0,5 3,45/1,6 1000 B3 (5) 9<br />
2,0/0,75 4,55/2,35 100 B3 (5) 9<br />
3,1/1,0 6,85/2,85 112 B3 (5) 9<br />
3000/1500 5,5/1,5 11,0/3,0 112 B3 (5) 9<br />
12/3,3 23/6,8 132 B3 (5) 9<br />
800 750 0,75 2,7 100 B3 9<br />
1,1 3,25 100 B3 9<br />
1,5 4,1 112 B3 9<br />
1000 1,5 3,9 100 B3 9<br />
2,2 5,35 112 B3 9<br />
3,0 6,7 132 B3 9<br />
4,0 9,0 132 B3 9<br />
1500 2,2 5,15 100 B3 9<br />
3,0 6,7 100 B3 9<br />
4,0 8,8 112 B3 9<br />
5,5 11,8 132 B3 9<br />
7,5 15 132 B3 9<br />
11 21 160 B3 9<br />
Fan-types showing no. of blades in ( ) are to be selected by technical services at the<br />
factory
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal<br />
speed<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
Size Type<br />
[rpm] �<br />
800 1500/750 3,6/0,9 7,9/3,3 112 B3 9<br />
4,5/1,1 10,5/3,8 132 B3 9<br />
6,5/1,8 13/4,5 132 B3 9<br />
9,0/2,3 18,5/5,5 160 B3 9<br />
12,5/3,5 25,5/9,1 160 B3 9<br />
1000 750 2,2 5,5 132 B3 (9) 12<br />
3,0 7,4 132 B3 (9) 12<br />
4,0 9,3 160 B3 (9) 12<br />
1000 3,0 6,7 132 B3 (9) 12<br />
4,0 9,0 132 B3 (9) 12<br />
5,5 11,5 132 B3 (9) 12<br />
7,5 15,5 160 B3 (9) 12<br />
11 21,5 160 B3 (9) 12<br />
1500 7,5 15 132 B3 (9) 12<br />
11 21 160 B3 (9) 12<br />
15 28 160 B3 (9) 12<br />
18,5 34,5 180 B3 12<br />
22 42 180 B3 12<br />
30 55,5 200 B3 12<br />
1000/500 3,3/0,75 9,3/3,6 132 B3 (9) 12<br />
4,4/1,0 11/4,4 132 B3 (9) 12<br />
6,3/1,5 15,7/5,4 160 B3 (9) 12<br />
8,8/2,2 20,5/7,0 160 B3 (9) 12<br />
12,5/3,0 32,5/11 180 B3 12<br />
1500/750 4,5/1,1 10,5/3,8 132 B3 (9) 12<br />
6,5/1,8 13/4,5 132 B3 (9) 12<br />
9,0/2,3 18,5/5,5 160 B3 (9) 12<br />
12,5/3,5 25,5/9,1 160 B3 (9) 12<br />
20/5,0 40/13 180 B3 12<br />
26/7,2 51/17,5 200 B3 12<br />
1120 1000 5,5 11,5 12 B3 12<br />
7,5 15,5 160 B3 12<br />
11 21,5 160 B3 12<br />
15 30,5 180 B3 12<br />
1500 11 21 160 B3 12<br />
15 28 160 B3 12<br />
18,5 34,5 180 B3 12<br />
22 42 180 B3 12<br />
30 55,5 200 B3 12<br />
37 67 200 B3 12<br />
1500/750 9,0/2,3 18,5/5,5 160 B3 12<br />
16/4,5 32,5/11,5 180 B3 12<br />
20/5,0 40/13 180 B3 12<br />
26/7,2 51/17,5 200 B3 12<br />
35/9,5 73/23,5 225 B3 12<br />
AXIAL FLOW FANS<br />
TECHNICAL LISTS (AVAILABLE MODELS)<br />
AXO SERIES<br />
Number<br />
of<br />
blades<br />
Fan Motor 400 V, 50 Hz - explosion-proof<br />
Size<br />
Nominal<br />
speed<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
Size Type<br />
[rpm] �<br />
043<br />
Number<br />
of<br />
blades<br />
315 1500 0,25 0,83 71 B3 8<br />
3000 0,37 1,05 71 B3 8<br />
0,55 1,36 71 B3 8<br />
400 1500 0,25 0,83 71 B3 8<br />
0,37 1,1 71 B3 8<br />
3000 1,1 2,2 80 B3 8<br />
1,5 3,05 90 B3 8<br />
2,0 3,8 90 B3 8<br />
500 1500 0,55 1,51 80 B3 (5) 9<br />
0,75 1,94 80 B3 (5) 9<br />
1,1 2,55 90 B3 (5) 9<br />
1,5 3,35 90 B3 (5) 9<br />
3000 4,6 8,2 132 B3 9<br />
5,5 9,6 132 B3 9<br />
630 750 0,55 1,69 90 B3 (5) 9<br />
1000 0,75 2,05 90 B3 (5) 9<br />
1,1 3,0 90 B3 (5) 9<br />
1500 1,1 2,55 90 B3 (5) 9<br />
2,0 4,0 100 B3 (5) 9<br />
800 1000 1,35 3,4 100 B3 9<br />
1,9 4,65 112 B3 9<br />
2,6 6,5 132 B3 9<br />
1500 4,0 7,6 112 B3 9<br />
6,8 13,3 132 B3 9<br />
1000 750 2,6 6,3 132 B3 (9) 12<br />
3,5 8,6 160 B3 (9) 12<br />
1000 4,8 10,9 132 B3 (9) 12<br />
6,6 14,3 160 B3 (9) 12<br />
9,7 21 160 B3 (9) 12<br />
13,2 28 160 B3 (9) 12<br />
Fan-types showing no. of blades in ( ) are to be selected by technical services at the<br />
factory<br />
� Nominal current = appr. values for 400 V motors (depending on brand)<br />
Technical Lists
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
40<br />
35,5<br />
31,5<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
710<br />
0,2<br />
2,5<br />
4,0<br />
800<br />
0,224<br />
900<br />
0,25<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 8/315/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u 2 = 23 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m 3<br />
1000<br />
0,28<br />
�<br />
1120<br />
0,315<br />
1250<br />
0,355<br />
1400<br />
0,4<br />
1600<br />
0,45<br />
1800<br />
0,5<br />
2000<br />
0,56<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 320 mm<br />
Outlet cross section A2 = 0,08 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
A hazardous-duty version is available<br />
only with 35° blade angle.<br />
2,8<br />
5,0<br />
25°<br />
3,15<br />
6,3<br />
3,55<br />
8,0<br />
4,0<br />
10<br />
30°<br />
4,5<br />
12,5<br />
5,0<br />
16<br />
5,6<br />
20<br />
6,3<br />
25<br />
7,1<br />
31,5<br />
2240<br />
0,63<br />
8,0<br />
40<br />
2500<br />
0,71<br />
9,0<br />
50<br />
2800<br />
0,8<br />
10<br />
63<br />
89<br />
87<br />
85<br />
83<br />
81<br />
79<br />
77<br />
75<br />
73<br />
71<br />
69<br />
044<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
25°<br />
35°<br />
� =<br />
0,49<br />
0,32<br />
40°<br />
0,46<br />
30°<br />
0,43<br />
0,40<br />
45°<br />
35°<br />
40°<br />
pd<br />
45° Blade pitch angle
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
1600<br />
0,45<br />
5,6<br />
20<br />
25°<br />
1800<br />
0,5<br />
6,3<br />
25<br />
2000<br />
0,56<br />
7,1<br />
31,5<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 8/315/D*<br />
ROTATIONAL SPEED 2800 RPM<br />
2240<br />
0,63<br />
8,0<br />
40<br />
30°<br />
Tip speed u 2 = 47 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m 3<br />
�<br />
2500<br />
0,71<br />
9,0<br />
50<br />
35°<br />
2800<br />
0,8<br />
10<br />
63<br />
� =<br />
0,49<br />
0,36<br />
25°<br />
3150<br />
0,9<br />
11,2<br />
80<br />
40°<br />
0,47<br />
0,44<br />
3550<br />
1,0<br />
12,5<br />
100<br />
0,40<br />
30°<br />
4000<br />
1,12<br />
14<br />
125<br />
45°<br />
4500<br />
1,25<br />
16<br />
160<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 320 mm<br />
Outlet cross section A2 = 0,08 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
A hazardous-duty version is available<br />
only with 35° blade angle.<br />
35°<br />
40°<br />
5000<br />
1,4<br />
18<br />
200<br />
pd<br />
45° Blade pitch angle<br />
5600<br />
1,6<br />
20<br />
250<br />
6300<br />
1,8<br />
22,4<br />
315<br />
103<br />
101<br />
99<br />
97<br />
95<br />
93<br />
91<br />
89<br />
87<br />
85<br />
83<br />
045<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
1600<br />
0,45<br />
3,55<br />
8,0<br />
1800<br />
0,5<br />
4,0<br />
10<br />
25°<br />
2000<br />
0,56<br />
4,5<br />
12,5<br />
30°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 8/400/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u2 = 30 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 2240<br />
0,63<br />
5,0<br />
16<br />
2500<br />
0,71<br />
5,6<br />
20<br />
�<br />
35°<br />
25°<br />
2800<br />
0,8<br />
6,3<br />
25<br />
� =<br />
0,54<br />
0,47<br />
3150<br />
0,9<br />
7,1<br />
31,5<br />
40°<br />
0,52<br />
3550<br />
1,0<br />
8,0<br />
40<br />
0,50<br />
45°<br />
30°<br />
4000<br />
1,12<br />
9,0<br />
50<br />
4500<br />
1,25<br />
10<br />
63<br />
40°<br />
5000<br />
1,4<br />
11,2<br />
80<br />
pd<br />
5600<br />
1,6<br />
12,5<br />
100<br />
6300<br />
1,8<br />
14<br />
125<br />
93<br />
91<br />
89<br />
87<br />
85<br />
83<br />
81<br />
79<br />
77<br />
75<br />
73<br />
046<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 401 mm<br />
Outlet cross section A2 = 0,126 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
A hazardous-duty version is available<br />
only with 35° blade angle.<br />
45° Blade pitch angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
35°
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
2800<br />
0,8<br />
6,3<br />
25<br />
3150<br />
0,9<br />
7,1<br />
31,5<br />
25°<br />
3550<br />
1,0<br />
8,0<br />
40<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 8/400/D*<br />
ROTATIONAL SPEED 2870 RPM<br />
Tip speed u2 = 60 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 4000<br />
1,12<br />
9,0<br />
50<br />
30°<br />
4500<br />
1,25<br />
10<br />
63<br />
�<br />
5000<br />
1,4<br />
11,2<br />
80<br />
25°<br />
5600<br />
1,6<br />
12,5<br />
100<br />
35°<br />
0,50<br />
0,48<br />
6300<br />
1,8<br />
14<br />
125<br />
40°<br />
0,53<br />
7100<br />
2,0<br />
16<br />
160<br />
30°<br />
8000<br />
2,24<br />
18<br />
200<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 401 mm<br />
Outlet cross section A2 = 0,126 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
A hazardous-duty version is available<br />
only with 35° blade angle.<br />
45°<br />
� =<br />
0,54 pd<br />
9000<br />
2,5<br />
20<br />
250<br />
40°<br />
10000<br />
2,8<br />
22,4<br />
315<br />
11200<br />
3,15<br />
25<br />
400<br />
107<br />
105<br />
103<br />
101<br />
99<br />
97<br />
95<br />
93<br />
91<br />
89<br />
87<br />
047<br />
45° Blade pitch angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
35°<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
20°<br />
2 800<br />
0,8<br />
4,0<br />
10<br />
3 150<br />
0,9<br />
4,5<br />
12,5<br />
3 550<br />
1,0<br />
5,0<br />
16<br />
25°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 5/500/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u2 = 38 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 4 000<br />
1,12<br />
5,6<br />
20<br />
20°<br />
30°<br />
4 500<br />
1,25<br />
6,3<br />
25<br />
�<br />
0,44<br />
5 000<br />
1,4<br />
7,1<br />
31,5<br />
5 600<br />
1,6<br />
8,0<br />
40<br />
0,48<br />
25°<br />
35° 40°<br />
6 300<br />
1,8<br />
9,0<br />
50<br />
� =<br />
0,51<br />
0,49<br />
7 100<br />
2,0<br />
10<br />
63<br />
30°<br />
8 000<br />
2,24<br />
11,2<br />
80<br />
32,5°<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 504 mm<br />
Outlet cross section A2 = 0,2 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
32,5°<br />
35°<br />
9 000<br />
2,5<br />
12,5<br />
100<br />
40°<br />
37,5°<br />
10 000<br />
2,8<br />
14<br />
125<br />
37,5°<br />
pd<br />
45° Blade pitch angle<br />
45°<br />
11 200<br />
3,15<br />
16<br />
160<br />
95<br />
93<br />
91<br />
89<br />
87<br />
85<br />
83<br />
81<br />
79<br />
77<br />
75<br />
048<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
4 000<br />
1,12<br />
5,6<br />
20<br />
4 500<br />
1,25<br />
6,3<br />
25<br />
5 000<br />
1,4<br />
7,1<br />
31,5<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 5/500/D*<br />
ROTATIONAL 2870 RPM<br />
5 600<br />
1,6<br />
8,0<br />
40<br />
6 300<br />
1,8<br />
9,0<br />
50<br />
20° 25°<br />
Tip speed u2 = 76 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 �<br />
7 100<br />
2,0<br />
10<br />
63<br />
8 000<br />
2,24<br />
11,2<br />
80<br />
30°<br />
0,48<br />
20°<br />
9 000<br />
2,5<br />
12,5<br />
100<br />
0,44<br />
10 000<br />
2,8<br />
14<br />
125<br />
� =<br />
0,51<br />
0,49<br />
11 200<br />
3,15<br />
16<br />
160<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 504 mm<br />
Outlet cross section A2 = 0,2 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
25°<br />
12 500<br />
3,55<br />
18<br />
200<br />
14 000<br />
4,0<br />
20<br />
250<br />
30°<br />
16 000<br />
4,5<br />
22,4<br />
315<br />
32,5°<br />
pd<br />
107<br />
105<br />
103<br />
101<br />
99<br />
97<br />
95<br />
93<br />
91<br />
89<br />
87<br />
049<br />
32,5° Blade pitch angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
35°<br />
7 100<br />
2,0<br />
10<br />
63<br />
8 000<br />
2,24<br />
11,2<br />
80<br />
9000<br />
2,5<br />
12,5<br />
100<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/500/D*<br />
ROTATIONAL SPEED 2870 RPM<br />
Tip speed u2 = 76 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 10 000<br />
2,8<br />
14<br />
125<br />
11 200<br />
3,15<br />
16<br />
160<br />
�<br />
37,5°<br />
12 500<br />
3,55<br />
18<br />
200<br />
0,46<br />
0,44<br />
0,40<br />
14 000<br />
4,0<br />
20<br />
250<br />
� =<br />
0,47<br />
16 000<br />
4,5<br />
22,4<br />
315<br />
35°<br />
18000<br />
5,0<br />
25<br />
400<br />
37,5°<br />
40°<br />
20 000<br />
5,6<br />
28<br />
500<br />
40°<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 504 mm<br />
Outlet cross section A2 = 0,2 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
pd<br />
45° Blade pitch angle<br />
22 400<br />
6,3<br />
31,5<br />
630<br />
45°<br />
25 000<br />
7,1<br />
35,5<br />
800<br />
28 000<br />
8,0<br />
40<br />
1 000<br />
115<br />
113<br />
111<br />
109<br />
107<br />
105<br />
103<br />
101<br />
99<br />
97<br />
94<br />
050<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
20°<br />
4 000<br />
1,12<br />
3,55<br />
8,0<br />
4 500<br />
1,25<br />
4,0<br />
10<br />
25°<br />
5 000<br />
1,4<br />
4,5<br />
12,5<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/630/D*<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u2 = 32 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 20°<br />
5 600<br />
1,6<br />
5,0<br />
16<br />
�<br />
6 300<br />
1,8<br />
5,6<br />
20<br />
32,5°<br />
30°<br />
25°<br />
7 100<br />
2,0<br />
6,3<br />
25<br />
35°<br />
0,56<br />
0,51<br />
8 000<br />
2,24<br />
7,1<br />
31,5<br />
0,58<br />
9 000<br />
2,5<br />
8,0<br />
40<br />
0,60<br />
30°<br />
10 000<br />
2,8<br />
9,0<br />
50<br />
� =<br />
0,62 pd<br />
32,5°<br />
11 200<br />
3,15<br />
10<br />
63<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 634 mm<br />
Outlet cross section A2 = 0,31 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
35°<br />
12 500<br />
3,55<br />
11,2<br />
80<br />
37,5°<br />
37,5°<br />
40°<br />
14 000<br />
4,0<br />
12,5<br />
100<br />
16 000<br />
4,5<br />
14<br />
125<br />
45°<br />
40°<br />
91<br />
89<br />
87<br />
85<br />
83<br />
81<br />
79<br />
77<br />
75<br />
73<br />
71<br />
051<br />
45° Blade pitch angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
20°<br />
5600<br />
1,6<br />
5,0<br />
16<br />
6300<br />
1,8<br />
5,6<br />
20<br />
7100<br />
2,0<br />
6,3<br />
25<br />
25°<br />
20°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/630/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u2 = 46 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 8000<br />
2,24<br />
7,1<br />
31,5<br />
30°<br />
9000<br />
2,5<br />
8,0<br />
40<br />
�<br />
32,5°<br />
25°<br />
10000<br />
2,8<br />
9,0<br />
50<br />
35°<br />
11200<br />
3,15<br />
10<br />
63<br />
0,52<br />
0,54<br />
12500<br />
3,55<br />
11,2<br />
80<br />
30°<br />
14000<br />
4,0<br />
12,5<br />
100<br />
16000<br />
4,5<br />
14<br />
125<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 634 mm<br />
Outlet cross section A2 = 0,31 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
0,56<br />
32,5°<br />
� =<br />
0,61<br />
35°<br />
18000<br />
5,0<br />
16<br />
160<br />
0,59<br />
37,5°<br />
40°<br />
20000<br />
5,6<br />
18<br />
200<br />
40°<br />
37,5°<br />
pd<br />
22400<br />
6,3<br />
20<br />
250<br />
45°<br />
103<br />
101<br />
99<br />
97<br />
95<br />
93<br />
91<br />
89<br />
87<br />
85<br />
83<br />
052<br />
45° Blade pitch angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
8000<br />
2,24<br />
7,1<br />
31,5<br />
0,48<br />
9000<br />
2,5<br />
8,0<br />
40<br />
10000<br />
2,8<br />
9,0<br />
50<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 5/630/D*<br />
ROTATIONAL SPEED 2880 RPM<br />
Tip speed u2 = 94 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 11200<br />
3,15<br />
10<br />
63<br />
12500<br />
3,55<br />
11,2<br />
80<br />
�<br />
0,50<br />
14000<br />
4,0<br />
12,5<br />
100<br />
20°<br />
16000<br />
4,5<br />
14<br />
125<br />
20°<br />
0,55<br />
18000<br />
5,0<br />
16<br />
160<br />
20000<br />
5,6<br />
18<br />
200<br />
0,58<br />
25°<br />
22400<br />
6,3<br />
20<br />
250<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 634 mm<br />
Outlet cross section A2 = 0,31 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
25°<br />
� =<br />
0,59<br />
25000<br />
7,1<br />
22,4<br />
315<br />
28000<br />
8,0<br />
25<br />
400<br />
30°<br />
31500<br />
9,0<br />
28<br />
500<br />
pd<br />
30° Blade pitch angle<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
053<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
11200<br />
3,15<br />
10<br />
63<br />
12500<br />
3,55<br />
11,2<br />
80<br />
14000<br />
4,0<br />
12,5<br />
100<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/630/D*<br />
ROTATIONAL SPEED 2880 RPM<br />
Tip speed u2 = 94 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 16000<br />
4,5<br />
14<br />
125<br />
0,54<br />
�<br />
18000<br />
5,0<br />
16<br />
160<br />
20000<br />
5,6<br />
18<br />
200<br />
0,56<br />
0,58<br />
22400<br />
6,3<br />
20<br />
250<br />
25000<br />
7,1<br />
22,4<br />
315<br />
� =<br />
0,61<br />
28000<br />
8,0<br />
25<br />
400<br />
31500<br />
9,0<br />
28<br />
500<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 634 mm<br />
Outlet cross section A2 = 0,31 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
32,5°<br />
35°<br />
35500<br />
10<br />
31,5<br />
630<br />
32,5° 35°<br />
40000<br />
11,2<br />
35,5<br />
800<br />
37,5°<br />
pd<br />
37,5° Blade pitch angle<br />
45000<br />
12,5<br />
40<br />
1000<br />
118<br />
116<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
054<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
25°<br />
25°<br />
30°<br />
30°
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
40<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
20°<br />
5 600<br />
1,6<br />
3,15<br />
6,3<br />
6 300<br />
1,8<br />
3,55<br />
8,0<br />
20°<br />
7 100<br />
2,0<br />
4,0<br />
10<br />
25°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/800/D*<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u2 = 30 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 8 000<br />
2,24<br />
4,5<br />
12,5<br />
�<br />
9 000<br />
2,5<br />
5,0<br />
16<br />
30°<br />
25°<br />
10 000<br />
2,8<br />
5,6<br />
20<br />
32,5°<br />
0,56<br />
0,51<br />
11 200<br />
3,15<br />
6,3<br />
25<br />
35°<br />
30°<br />
12 500<br />
3,55<br />
7,1<br />
31,5<br />
40°<br />
14 000<br />
4,0<br />
8,0<br />
40<br />
0,59<br />
32,5°<br />
16 000<br />
4,5<br />
9,0<br />
50<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 797 mm<br />
Outlet cross section A2 = 0,5 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
0,64<br />
� =<br />
0,67<br />
35°<br />
37,5°<br />
18 000<br />
5,0<br />
10<br />
63<br />
37,5°<br />
40°<br />
20 000<br />
5,6<br />
11,2<br />
80<br />
pd<br />
45° Blade pitch angle<br />
45°<br />
22 400<br />
6,3<br />
12,5<br />
100<br />
92<br />
90<br />
88<br />
86<br />
84<br />
82<br />
80<br />
78<br />
76<br />
74<br />
72<br />
055<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
20°<br />
7 100<br />
2,0<br />
4,0<br />
10<br />
8 000<br />
2,24<br />
4,5<br />
12,5<br />
25°<br />
20°<br />
9 000<br />
2,5<br />
5,0<br />
16<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/800/D*<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u2 = 39 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 10 000<br />
2,8<br />
5,6<br />
20<br />
30°<br />
11 200<br />
3,15<br />
6,3<br />
25<br />
�<br />
32,5°<br />
25°<br />
12 500<br />
3,55<br />
7,1<br />
31,5<br />
14 000<br />
4,0<br />
8,0<br />
40<br />
0,56<br />
0,50<br />
16 000<br />
4,5<br />
9,0<br />
50<br />
30°<br />
40°<br />
18 000<br />
5,0<br />
10<br />
63<br />
0,59<br />
20 000<br />
5,6<br />
11,2<br />
80<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 797 mm<br />
Outlet cross section A2 = 0,5 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
32,5°<br />
� =<br />
0,67<br />
0,65<br />
0,63<br />
35°<br />
22 400<br />
6,3<br />
12,5<br />
100<br />
35°<br />
37,5°<br />
25 000<br />
7,1<br />
14<br />
125<br />
37,5°<br />
40°<br />
28 000<br />
8,0<br />
16<br />
160<br />
pd<br />
45°<br />
96<br />
94<br />
92<br />
90<br />
88<br />
86<br />
84<br />
82<br />
80<br />
78<br />
76<br />
056<br />
45° Blade pitch angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
20°<br />
11 200<br />
3,15<br />
6,3<br />
25<br />
12 500<br />
3,55<br />
7,1<br />
31,5<br />
20°<br />
25°<br />
14 000<br />
4,0<br />
8,0<br />
40<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/800/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u2 = 60 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 16 000<br />
4,5<br />
9,0<br />
50<br />
18 000<br />
5,0<br />
10<br />
63<br />
�<br />
25°<br />
32,5°<br />
20 000<br />
5,6<br />
11,2<br />
80<br />
0,56<br />
0,52<br />
22 400<br />
6,3<br />
12,5<br />
100<br />
37,5°<br />
25 000<br />
7,1<br />
14<br />
125<br />
30°<br />
28 000<br />
8,0<br />
16<br />
160<br />
30°<br />
0,60<br />
32,5°<br />
31 500<br />
9,0<br />
18<br />
200<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 797 mm<br />
Outlet cross section A2 = 0,5 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
� =<br />
0,68 pd<br />
0,64<br />
35°<br />
35°<br />
37,5°<br />
35 500<br />
10<br />
20<br />
250<br />
40°<br />
40 000<br />
11,2<br />
22,4<br />
315<br />
45°<br />
40°<br />
45° Blade pitch angle<br />
45 000<br />
12,5<br />
25<br />
400<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
90<br />
88<br />
86<br />
057<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
40<br />
35,5<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
25°<br />
8 000<br />
2,24<br />
2,8<br />
5,0<br />
9 000<br />
2,5<br />
3,15<br />
6,3<br />
10 000<br />
2,8<br />
3,55<br />
8,0<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/1000/D*<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u2 = 38 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 11 200<br />
3,15<br />
4,0<br />
10<br />
12 500<br />
3,55<br />
4,5<br />
12,5<br />
�<br />
25°<br />
0,54<br />
0,52<br />
14 000<br />
4,0<br />
5,0<br />
16<br />
0,50<br />
16 000<br />
4,5<br />
5,6<br />
20<br />
0,56<br />
18 000<br />
5,0<br />
6,3<br />
25<br />
30°<br />
� =<br />
0,57<br />
20 000<br />
5,6<br />
7,1<br />
31,5<br />
30°<br />
22 400<br />
6,3<br />
8,0<br />
40<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1003 mm<br />
Outlet cross section A2 = 0,79 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
32,5°<br />
25 000<br />
7,1<br />
9,0<br />
50<br />
pd<br />
35°<br />
32,5°<br />
35° Blade pitch angle<br />
28 000<br />
8,0<br />
10<br />
63<br />
31 500<br />
9,0<br />
11,2<br />
80<br />
90<br />
88<br />
86<br />
84<br />
82<br />
80<br />
78<br />
76<br />
74<br />
72<br />
70<br />
058<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
25°<br />
12 500<br />
3,55<br />
4,5<br />
12,5<br />
14 000<br />
4,0<br />
5,0<br />
16<br />
25°<br />
16 000<br />
4,5<br />
5,6<br />
20<br />
30°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/1000/D*<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u2 = 51 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 18 000<br />
5,0<br />
6,3<br />
25<br />
0,48<br />
20 000<br />
5,6<br />
7,1<br />
31,5<br />
�<br />
22 400<br />
6,3<br />
8,0<br />
40<br />
30° 32,5°<br />
25 000<br />
7,1<br />
9,0<br />
50<br />
37,5°<br />
0,54<br />
28 000<br />
8,0<br />
10<br />
63<br />
0,56<br />
31 500<br />
9,0<br />
11,2<br />
80<br />
45°<br />
32,5°<br />
35°<br />
35 500<br />
10<br />
12,5<br />
100<br />
35°<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1003 mm<br />
Outlet cross section A2 = 0,79 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
0,60<br />
37,5°<br />
40 000<br />
11,2<br />
14<br />
125<br />
� =<br />
0,61<br />
0,58<br />
40°<br />
40°<br />
45 000<br />
12,5<br />
16<br />
160<br />
45°<br />
50 000<br />
14<br />
18<br />
200<br />
50°<br />
pd<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
90<br />
88<br />
86<br />
059<br />
50° Blade pitch angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
14 000<br />
4,0<br />
5,0<br />
16<br />
16 000<br />
4,5<br />
5,6<br />
20<br />
18 000<br />
5,0<br />
6,3<br />
25<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 9/1000/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u2 = 76 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 20 000<br />
5,6<br />
7,1<br />
31,5<br />
22 400<br />
6,3<br />
8,0<br />
40<br />
�<br />
25 000<br />
7,1<br />
9,0<br />
50<br />
25°<br />
0,52<br />
28 000<br />
8,0<br />
10<br />
63<br />
25°<br />
0,48<br />
31 500<br />
9,0<br />
11,2<br />
80<br />
0,54<br />
35 500<br />
10<br />
12,5<br />
100<br />
30°<br />
� =<br />
0,58<br />
40 000<br />
11,2<br />
14<br />
125<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1003 mm<br />
Outlet cross section A2 = 0,79 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
30°<br />
45 000<br />
12,5<br />
16<br />
160<br />
32,5°<br />
32,5°<br />
pd<br />
50 000<br />
14<br />
18<br />
200<br />
35° Blade pitch angle<br />
35°<br />
56 000<br />
16<br />
20<br />
250<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
060<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
0,56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
11 200<br />
3,15<br />
4,0<br />
10<br />
35°<br />
12 500<br />
3,55<br />
4,5<br />
12,5<br />
14 000<br />
4,0<br />
5,0<br />
16<br />
0,44<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 12/1000/D*<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u2 = 38 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 16 000<br />
4,5<br />
5,6<br />
20<br />
18 000<br />
5,0<br />
6,3<br />
25<br />
�<br />
20 000<br />
5,6<br />
7,1<br />
31,5<br />
37,5°<br />
0,52<br />
22 400<br />
6,3<br />
8,0<br />
40<br />
80<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
25 000<br />
7,1<br />
9,0<br />
50<br />
35°<br />
28 000<br />
8,0<br />
10<br />
63<br />
31 500<br />
9,0<br />
11,2<br />
80<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1003 mm<br />
Outlet cross section A2 = 0,79 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
� =<br />
0,58<br />
37,5°<br />
0,56<br />
40°<br />
35 500<br />
10<br />
12,5<br />
100<br />
40°<br />
45°<br />
40 000<br />
11,2<br />
14<br />
125<br />
45°<br />
pd<br />
50° Blade pitch angle<br />
45 000<br />
12,5<br />
16<br />
160<br />
50°<br />
100<br />
98<br />
96<br />
94<br />
92<br />
90<br />
88<br />
86<br />
84<br />
82<br />
061<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
22 400<br />
6,3<br />
8,0<br />
40<br />
25 000<br />
7,1<br />
9,0<br />
50<br />
35°<br />
0,40<br />
28 000<br />
8,0<br />
10<br />
63<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 12/1000/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u2 = 76 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 31 500<br />
9,0<br />
11,2<br />
80<br />
35 500<br />
10<br />
12,5<br />
100<br />
�<br />
0,50<br />
40 000<br />
11,2<br />
14<br />
125<br />
37,5°<br />
45 000<br />
12,5<br />
16<br />
160<br />
94<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
35°<br />
50 000<br />
14<br />
18<br />
200<br />
56 000<br />
16<br />
20<br />
250<br />
37,5°<br />
63 000<br />
18<br />
22,4<br />
315<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1003 mm<br />
Outlet cross section A2 = 0,79 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
0,56<br />
40°<br />
� =<br />
0,59<br />
0,52<br />
40°<br />
71 000<br />
20<br />
25<br />
400<br />
45°<br />
80 000<br />
22,4<br />
28<br />
500<br />
45° 50°<br />
pd<br />
50° Blade pitch angle<br />
90 000<br />
25<br />
31,5<br />
630<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
062<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
30°<br />
16 000<br />
4,5<br />
4,5<br />
12,5<br />
18 000<br />
5,0<br />
5,0<br />
16<br />
20 000<br />
5,6<br />
5,6<br />
20<br />
35°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 12/1120/D*<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u2 = 42 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 22 400<br />
6,3<br />
6,3<br />
25<br />
30°<br />
�<br />
25 000<br />
7,1<br />
7,1<br />
31,5<br />
32,5°<br />
28 000<br />
8,0<br />
8,0<br />
40<br />
40°<br />
32,5°<br />
0,47<br />
31 500<br />
9,0<br />
9,0<br />
50<br />
0,49<br />
35°<br />
35 500<br />
10<br />
10<br />
63<br />
40 000<br />
11,2<br />
11,2<br />
80<br />
37,5°<br />
37,5°<br />
0,53<br />
0,51<br />
40°<br />
45 000<br />
12,5<br />
12,5<br />
100<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1124 mm<br />
Outlet cross section A2 = 1,0 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
� =<br />
0,56<br />
50 000<br />
14<br />
14<br />
125<br />
45°<br />
45°<br />
pd<br />
56 000<br />
16<br />
16<br />
160<br />
50° Blade pitch angle<br />
50°<br />
63 000<br />
18<br />
18<br />
200<br />
105<br />
103<br />
101<br />
99<br />
97<br />
95<br />
93<br />
91<br />
89<br />
87<br />
85<br />
063<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
16 000<br />
4,5<br />
4,5<br />
12,5<br />
25°<br />
18 000<br />
5,0<br />
5,0<br />
16<br />
20 000<br />
5,6<br />
5,6<br />
20<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 12/1120/D*<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u2 = 57 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 25°<br />
22 400<br />
6,3<br />
6,3<br />
25<br />
25 000<br />
7,1<br />
7,1<br />
31,5<br />
�<br />
32,5°<br />
0,50<br />
0,45<br />
28 000<br />
8,0<br />
8,0<br />
40<br />
31 500<br />
9,0<br />
9,0<br />
50<br />
30°<br />
35 500<br />
10<br />
10<br />
63<br />
37,5°<br />
32,5°<br />
30°<br />
0,53<br />
40 000<br />
11,2<br />
11,2<br />
80<br />
45 000<br />
12,5<br />
12,5<br />
100<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1124 mm<br />
Outlet cross section A2 = 1,0 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
50 000<br />
14<br />
14<br />
125<br />
45°<br />
35°<br />
35°<br />
� =<br />
0,58<br />
37,5°<br />
0,56<br />
56 000<br />
16<br />
16<br />
160<br />
40°<br />
40°<br />
63 000<br />
18<br />
18<br />
200<br />
45°<br />
50°<br />
pd<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
90<br />
88<br />
86<br />
064<br />
50°<br />
Blade pitch<br />
angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
30°<br />
25°<br />
25 000<br />
7,1<br />
7,1<br />
31,5<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 12/1120/D*<br />
ROTATIONAL SPEED 1460 RPM<br />
Tip speed u2 = 86 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 �<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1124 mm<br />
Outlet cross section A2 = 1,0 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
28 000<br />
8,0<br />
8,0<br />
40<br />
32,5°<br />
31 500<br />
9,0<br />
9,0<br />
50<br />
35 500<br />
10<br />
10<br />
63<br />
0,43<br />
25°<br />
40 000<br />
11,2<br />
11,2<br />
80<br />
0,44<br />
45 000<br />
12,5<br />
12,5<br />
100<br />
30°<br />
50 000<br />
14<br />
14<br />
125<br />
065<br />
50°<br />
Blade pitch<br />
angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
32,5°<br />
56 000<br />
16<br />
16<br />
160<br />
0,46<br />
63 000<br />
18<br />
18<br />
200<br />
0,50<br />
35°<br />
0,52<br />
71 000<br />
20<br />
20<br />
250<br />
37,5°<br />
80 000<br />
22,4<br />
22,4<br />
315<br />
37,5°<br />
35°<br />
0,54<br />
40°<br />
90 000<br />
25<br />
25<br />
400<br />
� =<br />
0,57<br />
0,56<br />
40°<br />
45°<br />
100 000<br />
28<br />
28<br />
500<br />
50°<br />
45°<br />
pd<br />
115<br />
113<br />
111<br />
109<br />
107<br />
105<br />
103<br />
101<br />
99<br />
97<br />
95<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
31500<br />
9,0<br />
7,1<br />
31,5<br />
35500<br />
10<br />
8,0<br />
40<br />
40000<br />
11,2<br />
9,0<br />
50<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 6/1250/D<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u2 = 65 m/s<br />
Temperaturee t = 20°C<br />
Density = 1,2 kg/m3 45000<br />
12,5<br />
10<br />
63<br />
50000<br />
14<br />
11,2<br />
80<br />
�<br />
56000<br />
16<br />
12,5<br />
63000<br />
18<br />
14<br />
71000<br />
20<br />
16<br />
80000<br />
22,4<br />
18<br />
90000<br />
25<br />
20<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1261 mm<br />
Outlet cross section A2 = 1,25 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
0,46<br />
25°<br />
100<br />
20° 25°<br />
0,50<br />
125<br />
� = 0,58<br />
0,56<br />
160<br />
0,57<br />
0,54<br />
200<br />
30°<br />
30°<br />
35°<br />
250<br />
35°<br />
40°<br />
100000<br />
28<br />
22,4<br />
315<br />
40°<br />
45°<br />
112000<br />
31,5<br />
25<br />
400<br />
45°<br />
pd<br />
50° Blade pitch<br />
angle<br />
125000<br />
35,5<br />
28<br />
500<br />
50°<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
066<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
45000<br />
12,5<br />
10<br />
63<br />
50000<br />
14<br />
11,2<br />
80<br />
56000<br />
16<br />
12,5<br />
100<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 6/1250/D<br />
ROTATIONAL SPEED 1460 RPM<br />
Tip speed u2 = 98 m/s<br />
Temperaturee t = 20°C<br />
Density = 1,2 kg/m3 63000<br />
18<br />
14<br />
125<br />
71000<br />
20<br />
16<br />
160<br />
�<br />
80000<br />
22,4<br />
18<br />
90000<br />
25<br />
20<br />
100000<br />
28<br />
22,4<br />
112000<br />
31,5<br />
25<br />
125000<br />
35,5<br />
28<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1261 mm<br />
Outlet cross section A2 = 1,25 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,46<br />
200<br />
25°<br />
250<br />
0,52<br />
0,49<br />
315<br />
450<br />
� = 0,56<br />
0,55<br />
0,54<br />
25° 30°<br />
30°<br />
500<br />
35°<br />
140000<br />
40<br />
31,5<br />
630<br />
35°<br />
40°<br />
160000<br />
45<br />
35,5<br />
800<br />
45°<br />
180000<br />
50<br />
40<br />
1000<br />
45°<br />
40°<br />
50°<br />
pd<br />
50° Blade pitch<br />
angle<br />
122<br />
120<br />
118<br />
116<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
067<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
45000<br />
12,5<br />
10<br />
63<br />
50000<br />
14<br />
11,2<br />
80<br />
56000<br />
16<br />
12,5<br />
100<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 8/1250/D<br />
ROTATIONAL SPEED 1460 RPM<br />
Tip speed u2 = 96 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 63000<br />
18<br />
14<br />
125<br />
71000<br />
20<br />
16<br />
160<br />
�<br />
80000<br />
22,4<br />
18<br />
90000<br />
25<br />
20<br />
100000<br />
28<br />
22,4<br />
112000<br />
31,5<br />
25<br />
125000<br />
35,5<br />
28<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1261 mm<br />
Outlet cross section A2 = 1,25 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,45<br />
200<br />
25°<br />
250<br />
25°<br />
0,50<br />
0,47<br />
315<br />
� = 0,55<br />
0,54<br />
0,52<br />
400<br />
30°<br />
30°<br />
500<br />
35°<br />
35°<br />
140000<br />
40<br />
31,5<br />
630<br />
40°<br />
40°<br />
160000<br />
45<br />
35,5<br />
800<br />
50° Blade pitch<br />
angle<br />
45°<br />
45°<br />
180000<br />
50<br />
40<br />
1000<br />
pd<br />
50°<br />
122<br />
120<br />
118<br />
116<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
068<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
31500<br />
9,0<br />
5,6<br />
20<br />
35000<br />
10<br />
6,3<br />
25<br />
40000<br />
11,2<br />
7,1<br />
31,5<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 6/1400/D<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u2 = 55 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 45000<br />
12,5<br />
8,0<br />
40<br />
50000<br />
14<br />
9,0<br />
50<br />
�<br />
56000<br />
16<br />
10<br />
63000<br />
18<br />
11,2<br />
71000<br />
20<br />
12,5<br />
80000<br />
22,4<br />
14<br />
90000<br />
25<br />
16<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A2 = 1,57 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,48<br />
25°<br />
63<br />
80<br />
25°<br />
0,52<br />
100<br />
� = 0,59<br />
0,55<br />
30°<br />
30°<br />
125<br />
0,57<br />
35°<br />
160<br />
35°<br />
100000<br />
28<br />
18<br />
200<br />
40°<br />
40°<br />
45°<br />
112000<br />
31,5<br />
20<br />
250<br />
50°<br />
45°<br />
pd<br />
50° Blade pitch<br />
angle<br />
125000<br />
35,5<br />
22,4<br />
315<br />
106<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
90<br />
88<br />
069<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
31500<br />
9,0<br />
5,6<br />
20<br />
35500<br />
10<br />
6,3<br />
25<br />
40000<br />
11,2<br />
7,1<br />
31,5<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 8/1400/D<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u2 = 55 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 45000<br />
12,5<br />
8,0<br />
40<br />
50000<br />
14<br />
9,0<br />
50<br />
�<br />
56000<br />
16<br />
10<br />
63000<br />
18<br />
11,2<br />
71000<br />
20<br />
12,5<br />
80000<br />
22,4<br />
14<br />
90000<br />
25<br />
16<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A2 = 1,57 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,50<br />
63<br />
25°<br />
0,55<br />
0,52<br />
80<br />
� = 0,59<br />
100<br />
0,57<br />
25° 30°<br />
30°<br />
125<br />
160<br />
35°<br />
35°<br />
100000<br />
28<br />
18<br />
200<br />
40°<br />
40°<br />
112000<br />
31,5<br />
20<br />
250<br />
45°<br />
45°<br />
125000<br />
35,5<br />
22,4<br />
315<br />
pd<br />
50° Blade pitch<br />
angle<br />
50°<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
90<br />
070<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
31500<br />
9,0<br />
5,6<br />
20<br />
35500<br />
10<br />
6,3<br />
25<br />
40000<br />
11,2<br />
7,1<br />
31,5<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 10/1400/D<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u2 = 55 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 45000<br />
12,5<br />
8,0<br />
40<br />
50000<br />
14<br />
9,0<br />
50<br />
�<br />
56000<br />
16<br />
10<br />
63000<br />
18<br />
11,2<br />
71000<br />
20<br />
12,5<br />
80000<br />
22,4<br />
14<br />
90000<br />
25<br />
16<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A2 = 1,57 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
25°<br />
63<br />
80<br />
0,44<br />
100<br />
30°<br />
0,48<br />
125<br />
25° 30°<br />
� = 0,51<br />
0,46<br />
0,50<br />
160<br />
35°<br />
35°<br />
100000<br />
28<br />
18<br />
200<br />
40°<br />
40°<br />
112000<br />
31,5<br />
20<br />
250<br />
45°<br />
45°<br />
125000<br />
35,5<br />
22,4<br />
315<br />
pd<br />
50° Blade pitch<br />
angle<br />
50°<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
071<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
40000<br />
11,2<br />
7,1<br />
31,5<br />
45000<br />
12,5<br />
8,0<br />
40<br />
50000<br />
14<br />
9,0<br />
50<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 6/1400/D<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u2 = 73 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 56000<br />
16<br />
10<br />
63<br />
63000<br />
18<br />
11,2<br />
80<br />
�<br />
71000<br />
20<br />
12,5<br />
80000<br />
22,4<br />
14<br />
90000<br />
25<br />
16<br />
100000<br />
28<br />
18<br />
112000<br />
31,5<br />
20<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A2 = 1,57 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,45<br />
100<br />
25°<br />
125<br />
25°<br />
0,50<br />
160<br />
0,57<br />
200<br />
� = 0,59<br />
0,54<br />
30°<br />
30°<br />
250<br />
35°<br />
35°<br />
125000<br />
35,5<br />
22,4<br />
315<br />
40°<br />
140000<br />
40<br />
25<br />
400<br />
40°<br />
50° Blade pitch<br />
angle<br />
45°<br />
45°<br />
160000<br />
45<br />
28<br />
500<br />
pd<br />
50°<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
072<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
63000<br />
18<br />
11,2<br />
80<br />
71000<br />
20<br />
12,5<br />
100<br />
80000<br />
22,4<br />
14<br />
125<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 6/1400/D<br />
ROTATIONAL SPEED 1460 RPM<br />
Tip speed u2 = 108 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 90000<br />
25<br />
16<br />
160<br />
100000<br />
28<br />
18<br />
200<br />
�<br />
112000<br />
31,5<br />
20<br />
125000<br />
35,5<br />
22,4<br />
140000<br />
40<br />
25<br />
160000<br />
45<br />
28<br />
180000<br />
50<br />
31,5<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A2 = 1,57 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,48<br />
25°<br />
250<br />
25°<br />
0,51<br />
315<br />
0,57<br />
400<br />
� = 0,59<br />
0,55<br />
0,53<br />
30°<br />
30°<br />
500<br />
630<br />
35°<br />
35°<br />
40°<br />
200000<br />
56<br />
35,5<br />
800<br />
45°<br />
224000<br />
63<br />
40<br />
1000<br />
40° 45°<br />
50°<br />
pd<br />
50° Blade pitch<br />
angle<br />
250000<br />
71<br />
45<br />
1250<br />
122<br />
120<br />
118<br />
116<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
073<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
63000<br />
18<br />
11,2<br />
80<br />
71000<br />
20<br />
12,5<br />
100<br />
80000<br />
22,4<br />
14<br />
125<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 8/1400/D<br />
ROTATIONAL SPEED 1460 RPM<br />
Tip speed u2 = 108 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 90000<br />
25<br />
16<br />
160<br />
100000<br />
28<br />
18<br />
200<br />
�<br />
112000<br />
31,5<br />
20<br />
125000<br />
35,5<br />
22,4<br />
140000<br />
40<br />
25<br />
160000<br />
45<br />
28<br />
180000<br />
50<br />
31,5<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A2 = 1,57 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,49<br />
250<br />
25°<br />
315<br />
25°<br />
0,53<br />
400<br />
30°<br />
30°<br />
500<br />
� = 0,59<br />
0,55<br />
0,57<br />
630<br />
35°<br />
35°<br />
200000<br />
56<br />
35,5<br />
800<br />
40°<br />
40°<br />
224000<br />
63<br />
40<br />
1000<br />
45°<br />
45°<br />
250000<br />
71<br />
45<br />
1250<br />
50° Blade pitch<br />
angle<br />
50°<br />
pd<br />
124<br />
122<br />
120<br />
118<br />
116<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
074<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
2000<br />
1800<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
63000<br />
18<br />
11,2<br />
80<br />
71000<br />
20<br />
12,5<br />
100<br />
80000<br />
22,4<br />
14<br />
125<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 10/1400/D<br />
ROTATIONAL SPEED 1460 RPM<br />
Tip speed u2 = 109 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 90000<br />
25<br />
16<br />
160<br />
100000<br />
28<br />
18<br />
200<br />
�<br />
112000<br />
31,5<br />
20<br />
125000<br />
35,5<br />
22,4<br />
140000<br />
40<br />
25<br />
160000<br />
45<br />
28<br />
180000<br />
50<br />
31,5<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A2 = 1,57 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,45<br />
25°<br />
250<br />
315<br />
25°<br />
0,46<br />
30°<br />
400<br />
0,50<br />
0,48<br />
� = 0,51<br />
500<br />
630<br />
30° 35°<br />
35°<br />
200000<br />
56<br />
35,5<br />
800<br />
40°<br />
40°<br />
224000<br />
63<br />
40<br />
1000<br />
45°<br />
45°<br />
250000<br />
71<br />
45<br />
1250<br />
50°<br />
pd<br />
50° Blade pitch<br />
angle<br />
126<br />
124<br />
122<br />
120<br />
118<br />
116<br />
114<br />
112<br />
110<br />
108<br />
106<br />
075<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
45000<br />
12,5<br />
6,3<br />
25<br />
50000<br />
14<br />
7,1<br />
31,5<br />
56000<br />
16<br />
8,0<br />
40<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 8/1600/D<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u2 = 61 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 63000<br />
18<br />
9,0<br />
50<br />
71000<br />
20<br />
10<br />
63<br />
�<br />
80000<br />
22,4<br />
11,2<br />
90000<br />
25<br />
12,5<br />
100000<br />
28<br />
14<br />
112000<br />
31,5<br />
16<br />
125000<br />
35,5<br />
18<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1587 mm<br />
Outlet cross section A2 = 1,98 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,49<br />
25°<br />
25°<br />
80<br />
0,51<br />
100<br />
30°<br />
125<br />
30°<br />
0,56<br />
0,54<br />
160<br />
35°<br />
� = 0,62<br />
0,60<br />
0,58<br />
35°<br />
200<br />
40°<br />
140000<br />
40<br />
20<br />
250<br />
45°<br />
160000<br />
45<br />
22,4<br />
315<br />
45°<br />
40°<br />
pd<br />
50°<br />
50° Blade pitch<br />
angle<br />
180000<br />
50<br />
25<br />
400<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
076<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
56000<br />
16<br />
8,0<br />
40<br />
63000<br />
18<br />
9,0<br />
50<br />
71000<br />
20<br />
10<br />
63<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 8/1600/D<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u2 = 84 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 80000<br />
22,4<br />
11,2<br />
80<br />
90000<br />
25<br />
12,5<br />
100<br />
�<br />
100000<br />
28<br />
14<br />
112000<br />
31,5<br />
16<br />
125000<br />
35,5<br />
18<br />
140000<br />
40<br />
20<br />
160000<br />
45<br />
22,4<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1587 mm<br />
Outlet cross section A2 = 1,98 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
0,50<br />
25°<br />
125<br />
25°<br />
0,53<br />
160<br />
30°<br />
200<br />
30°<br />
0,56<br />
250<br />
315<br />
35°<br />
� = 0,61<br />
0,57<br />
35°<br />
0,59<br />
180000<br />
50<br />
25<br />
400<br />
40°<br />
40°<br />
200000<br />
56<br />
28<br />
500<br />
45°<br />
45°<br />
224000<br />
63<br />
31,5<br />
630<br />
50°<br />
pd<br />
50° Blade pitch<br />
angle<br />
118<br />
116<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
077<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
AXO-Direct-drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dyn. pressure [Pa] bzw. x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
56000<br />
16<br />
8,0<br />
40<br />
63000<br />
18<br />
9,0<br />
50<br />
71000<br />
20<br />
10<br />
63<br />
CHARACTERISTIC CURVES - AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE BVAXO 10/1600/D<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u2 = 81 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 80000<br />
22,4<br />
11,2<br />
80<br />
90000<br />
25<br />
12,5<br />
100<br />
�<br />
100000<br />
28<br />
14<br />
112000<br />
31,5<br />
16<br />
125000<br />
35,5<br />
18<br />
140000<br />
40<br />
20<br />
160000<br />
45<br />
22,4<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 1587 mm<br />
Outlet cross section A2 = 1,98 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
20°<br />
20°<br />
25°<br />
125<br />
25°<br />
0,44<br />
160<br />
30°<br />
200<br />
30°<br />
0,50<br />
� = 0,52<br />
0,48<br />
0,46<br />
250<br />
0,51<br />
315<br />
35°<br />
35°<br />
180000<br />
50<br />
25<br />
400<br />
40°<br />
40°<br />
200000<br />
56<br />
28<br />
500<br />
45°<br />
45°<br />
224000<br />
63<br />
31,5<br />
630<br />
50°<br />
pd<br />
50° Blade pitch<br />
angle<br />
118<br />
116<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
98<br />
078<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]
Item<br />
Nr.<br />
or<br />
or<br />
or<br />
or<br />
or<br />
Qty. Description<br />
– 079 –<br />
<strong>Axial</strong> Flow Fan – AXO Series, Type M-D<br />
Airflow direction: motor in outlet<br />
Direct-drive type<br />
<strong>Axial</strong> Flow Fan – AXO Series, Type M-S<br />
Airflow direction: motor in inlet<br />
Direct-drive type<br />
consisting of<br />
Casing of welded sheet steel construction<br />
with drilled flanges<br />
according to DIN 24 154, Series 3<br />
Surface protection:<br />
• Polyester powder coating<br />
Colour: RAL 7030<br />
• Hot-dip galvanized<br />
Aluminium hub<br />
Blades made of plastic (PP), non-adjustable,<br />
Placed on the shaft end of the<br />
3-phase a.c. standard motor<br />
Type 3<br />
Protection class IP 54, wired to exterior terminal box<br />
Outlet-side installation:<br />
• Duct connection<br />
• Direct outlet without diffuser<br />
• Outlet into short-type diffuser<br />
without interior core (optional)<br />
Specifications<br />
Volume flow m3/h Dynamic inlet pressure Pa<br />
Dynamic outlet pressure Pa<br />
Total pressure increase of fan Pa<br />
Pressure loss of accessories Pa<br />
External pressure loss Pa<br />
Temperature °C<br />
Density kg/m3 Fan rotational speed rpm<br />
Blade pitch angle °<br />
Total acoustic power level L w<br />
dB<br />
Efficiency %<br />
Power required at shaft kW<br />
Three-phase a.c. motor<br />
• single-speed<br />
• with Dahlander pole-changing type<br />
• pole-changing type with separate windings<br />
Motor speed rpm<br />
Motor output kW<br />
Current consumption A<br />
Voltage Volt<br />
Frequency Hz<br />
Weight kg<br />
Manufacturer: <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Type: AXO / M-D<br />
Type: AXO / M-S<br />
Carryover<br />
Unit price<br />
2<br />
Total<br />
2<br />
AXO-Direct drive
Item<br />
Nr.<br />
Qty. Description<br />
Options:<br />
• Galvanized fan<br />
• Fan with special coating<br />
– 080 –<br />
• Extension casing (without inspection hatch)<br />
• Inspection hatch<br />
• Bellmouth inlet with flange<br />
• Wire guard on inlet<br />
• Wire guard on extension casing (motor side)<br />
• Flexible connector, inlet side *<br />
• Flexible connector, outlet side *<br />
• Matching flange, inlet side *<br />
• Matching flange, outlet side *<br />
• Angular wall ring with brackets *<br />
• Set of mounting feet (2 pcs.)<br />
• Set of spring-type antivibration mounts *<br />
• Brackets for vertical fan installation<br />
• Diffuser without interior core *<br />
• Outlet duct with wire guard *<br />
• Duct with self-activating damper *<br />
• Insulating casing<br />
Note: Please see our Installation, Operating<br />
and Maintenance Instructions,<br />
available upon request.<br />
* Loosely supplied<br />
Carryover<br />
Unit price<br />
2<br />
Total<br />
2
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
View „A“<br />
View "B"<br />
(shown without louvre-type damper)<br />
Please refer to characteristic<br />
curves on pages 046 to 057.<br />
Size<br />
WALL-MOUNTING AXIAL FANS<br />
WAXO SERIES<br />
200 / 300 °C – 120 MIN<br />
200/300°C - 120 MIN.<br />
Direction of flow<br />
Pressure losses of fan and shutoff damper sum up to the total<br />
pressure increase needed for the sizing of complete fan units<br />
(assuming free inlet / free outlet conditions).<br />
*For flow velocities please refer to the characteristic curves.<br />
900<br />
330<br />
450<br />
Wall opening<br />
Dimensions in mm<br />
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).<br />
081<br />
Pressure loss across shutoff damper (overpressure louvre)<br />
Flow velocity*c<br />
Weight<br />
approx. [kg]<br />
(without<br />
motor)<br />
25<br />
40<br />
65<br />
90<br />
WAXO
Item<br />
Nr.<br />
Qty. Description<br />
or<br />
or<br />
– 082 –<br />
Wall-mounting <strong>Axial</strong> Flow Fan, WAXO Series<br />
Type M-D<br />
Airflow direction: motor in outlet, direct drive.<br />
Wall-mounting type<br />
Consisting of:<br />
Duct casing of welded sheet steel construction, with drilled<br />
flanges according to DIN 24154 - Series 3, 3-phase a.c.<br />
standard motor arranged in the flow, with terminal box fitted<br />
on the casing.<br />
Surface protection:<br />
• Polyester powder coating, colour: RAL 7030<br />
Louvre damper slats: made of aluminium<br />
Louvre damper frame and wire guard: galvanized.<br />
• Impeller made of cast aluminium, directly mounted on motor<br />
shaft, non-adjustable blades<br />
• Bellmouth with wire guard<br />
• Wall-mounting plate (inside)<br />
• Outlet box (outside)<br />
• Louvre damper (outside)<br />
Specifications<br />
Volume flow m3/h Dynamic inlet pressure Pa<br />
Dynamic outlet pressure Pa<br />
Total pressure increase of fan Pa<br />
Pressure loss of accessories Pa<br />
External pressure loss Pa<br />
Temperature °C<br />
Density kg/m3 Fan rotational speed rpm<br />
Blade pitch angle °<br />
Total acoustic power level L w<br />
Efficiency %<br />
Power required at shaft kW<br />
Three-phase motor:<br />
single-speed<br />
with Dahlander pole-changing type<br />
pole-changing type with separate windings<br />
Motor speed rpm<br />
Motor output kW<br />
Nominal motor current A<br />
Voltage V<br />
Frequency Hz<br />
Protection class IP<br />
Style B<br />
Size<br />
Weight of fan with accessories kg<br />
Manufacturer: <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Type: WAXO<br />
Accessory equipment needed in connection with use of inlet<br />
duct<br />
• Flexible connector (in this case please deduct price of<br />
bellmouth and inlet wire guard from fan price)<br />
Note: Please observe our Installation, Operating and Maintenance<br />
Instructions (available upon request).<br />
dB<br />
Unit price<br />
2<br />
Total<br />
2
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
AXIAL FLOW FANS<br />
TECHNICAL LISTS (AVAILABLE MODELS)<br />
AXN 12/56 SERIES<br />
Flange<br />
dia.<br />
250 3000 0-20 0,25 • 0,65 63 B14 120<br />
21-30 0,37 • 1,0 71 B14 120<br />
31-35 0,55 • 1,35 71 B14 120<br />
3000/1500 0-30 0,37/0,08 • 0,75/0,23 71 B14 120<br />
280 3000 0-10 0,25 • 0,65 63 B14 120<br />
11-20 0,37 • 1,0 71 B14 120<br />
21-30 0,55 • 1,35 71 B14 120<br />
31-35 0,75 • 1,7 80 B14 120<br />
3000/1500 0-20 0,37/0,08 • 0,75/0,23 71 B14 120<br />
21-30 0,55/0,13 • 1,33/0,32 71 B14 120<br />
31-35 0,75/0,2 • 1,7/0,5 80 B14 120<br />
315 1500 0-35 0,25 • 0,75 71 B5 160<br />
3000 0-13 0,55 • 1,35 71 B5 160<br />
14-20 0,75 • 1,7 80 B14 160<br />
21-32 1,1 • 2,4 80 B14 160<br />
1500/750 0-35 0,22/0,05 0,95/0,38 71 B5 160<br />
3000/1500 0-13 0,55/0,13 • 1,33/0,32 71 B5 160<br />
14-20 0,75/0,2 • 1,7/0,5 80 B14 160<br />
21-32 1,1/0,26 • 2,5/0,7 80 B14 160<br />
355 1500 0-32 0,25 • 0,75 71 B5 160<br />
3000 0-7 0,75 • 1,7 80 B14 160<br />
8-16 1,1 • 2,4 80 B14 160<br />
17-25 1,5 • 3,3 90 B14 160<br />
26-35 2,2 • 4,6 90 B14 160<br />
1500/750 0-30 0,22/0,05 0,95/0,38 71 B5 160<br />
3000/1500 0-7 0,75/0,2 • 1,7/0,5 80 B14 160<br />
8-16 1,1/0,26 • 2,5/0,7 80 B14 160<br />
17-30 1,8/0,37 • 4,1/0,9 90 B14 160<br />
400 1500 0-20 0,25 • 0,75 71 B5 160<br />
21-30 0,37 1,0 71 B5 160<br />
31-35 0,55 • 1,5 80 B5 200<br />
3000 0-10 1,5 • 3,3 90 B5 200<br />
11-19 2,2 • 4,6 90 B5 200<br />
20-27 3,0 • 6,2 100 B14 200<br />
28-35 4,0 • 7,9 112 B14 200<br />
1500/750 0-23 0,3/0,06 1,15/0,43 71 B5 160<br />
24-35 0,55/0,12 • 1,4/0,6 80 B5 200<br />
3000/1500 0-15 1,8/0,37 • 4,1/0,9 90 B5 200<br />
16-27 3,0/0,75 6,7/1,7 100 B14 200<br />
28-35 4,8/1,2 • 9,4/2,4 112 B14 200<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
� Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.<br />
It is important to check nominal current in case of other motor brands.*ATB motors<br />
083<br />
Flange<br />
dia.<br />
450 1500 0-22 0,55 • 1,5 80 B5 200<br />
23-31 0,75 • 2,0 80 B5 200<br />
32-35 1,1 • 2,7 90 B5 200<br />
3000 0-13 3,0 • 6,2 100 B14 200<br />
14-20 4,0 • 7,9 112 B14 200<br />
21-30 5,5 11,7 112 B14 200<br />
31-35 7,5 16,6 112 B14 200<br />
1500/750 0-22 0,55/0,12 • 1,4/0,6 80 B5 200<br />
23-30 0,7/0,18 2,0/0,8 80 B5 200<br />
3000/1500 0-13 3,0/0,75 6,7/1,7 100 B14 200<br />
14-25 4,8/1,2 • 9,4/2,4 112 B14 200<br />
500 1000 0-35 0,55 1,6 80 B5 200<br />
1500 0-15 0,75 • 2,0 80 B5 200<br />
16-25 1,1 • 2,7 90 B5 200<br />
26-35 1,5 • 3,5 90 B5 200<br />
3000 0-5 4,0 • 7,9 112 B14 200<br />
6-12 5,5 11 132 B5 250<br />
13-20 7,5 14,6 132 B5 250<br />
21-30 11 21 132 B5 250<br />
31-35 15 30 132 B5 250<br />
1000/500 0-30 0,33/0,05 1,15/0,33 80 B5 200<br />
1500/750 0-14 0,7/0,18 2,0/0,8 80 B5 200<br />
15-25 1,0/0,25 • 2,5/1,05 90 B5 200<br />
26-35 1,4/0,35 • 3,3/1,4 90 B5 200<br />
1500/1000 0-25 1,1/0,37 2,8/1,35 90 B5 200<br />
26-35 1,6/0,6 3,9/1,8 100 B5 250<br />
3000/1500 0-10 4,8/1,2 • 9,4/2,4 112 B5 250<br />
11-15 6,0/1,5 13,3/3,2 132 B5 250<br />
16-22 7,8/2,0 16,2/4,1 132 B5 250<br />
560 1000 0-26 0,55 1,6 80 B5 200<br />
27-35 0,75 2,2 90 B5 200<br />
1500 0-13 1,1 • 2,7 90 B5 200<br />
14-20 1,5 • 3,5 90 B5 200<br />
21-30 2,2 • 4,8 100 B5 250<br />
31-35 3,0 • 6,6 100 B5 250<br />
1000/500 0-35 0,8/0,15 2,3/0,9 90 B5 200<br />
1500/750 0-17 1,4/0,35 • 3,3/1,4 90 B5 200<br />
18-35 2,6/0,65 • 5,9/2,1 100 B5 250<br />
1500/1000 0-13 1,1/0,37 2,8/1,35 90 B5 200<br />
14-20 1,6/0,6 3,9/1,8 100 B5 250<br />
21-30 2,2/0,75 5,3/2,3 100 B5 250<br />
31-35 3,0/1,0 6,3/3,0 112 B5 250<br />
Technical Lists
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
AXIAL FLOW FANS<br />
TECHNICAL LISTS (AVAILABLE MODELS)<br />
AXN 12/56 SERIES<br />
Flange<br />
dia.<br />
630 750 0-35 0,55 1,8 90 B5 200<br />
1000 0-12 0,55 1,6 80 B5 200<br />
13-20 0,75 2,2 90 B5 200<br />
21-30 1,1 3,15 90 B5 200<br />
31-35 1,5 3,9 100 B5 250<br />
1500 0-6 1,5 • 3,5 90 B5 200<br />
7-15 2,2 • 4,8 100 B5 250<br />
16-23 3,0 • 6,6 100 B5 250<br />
24-30 4,0 • 8,8 112 B5 250<br />
31-35 5,5 • 11,5 132 B5 250<br />
1000/500 0-20 0,8/0,15 2,3/0,9 90 B5 200<br />
21-33 1,2/0,22 3,1/1,15 100 B5 250<br />
1500/750 0-20 2,6/0,65 • 5,9/2,1 100 B5 250<br />
21-26 3,6/0,9 • 7,6/3,0 112 B5 250<br />
27-35 5,5/1,4 11,4/4,3 132 B5 250<br />
1500/1000 0-15 2,2/0,75 5,3/2,3 100 B5 250<br />
16-23 3,0/1,0 6,3/3,0 112 B5 250<br />
24-35 6,0/2,0 12,5/5,4 132 B5 250<br />
710 750 0-17 0,55 1,8 90 B5 200<br />
18-25 0,75 2,2 100 B5 250<br />
26-35 1,1 3,15 100 B5 250<br />
1000 0-12 1,1 3,15 90 B5 200<br />
13-19 1,5 3,9 100 B5 250<br />
20-30 2,2 5,4 112 B5 250<br />
31-35 3,0 7,4 132 B5 250<br />
1500 0-6 3,0 • 6,6 100 B5 250<br />
7-13 4,0 • 8,8 112 B5 250<br />
14-20 5,5 • 11,5 132 B5 250<br />
21-28 7,5 • 15,5 132 B5 250<br />
29-35 11 22 160 B5 350<br />
1000/500 0-12 1,2/0,22 3,0/1,15 100 B5 250<br />
13-35 3,3/0,75 9,3/3,6 132 B5 250<br />
1500/750 0-20 5,5/1,4 11,4/4,3 132 B5 250<br />
21-26 7,0/1,7 • 15/6,0 132 B5 250<br />
27-35 11/3,0 24/9,5 160 B5 350<br />
1500/1000 0-16 4,5/1,5 9,5/3,8 132 B5 250<br />
17-25 6,0/2,0 12,5/5,4 132 B5 250<br />
26-30 8,5/3,0 17,9/7,6 160 B5 350<br />
31-35 12/3,5 24/9,5 160 B5 350<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
� Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.<br />
It is impöortant to check nominal current in case of other motor brands.*ATB motors<br />
084<br />
Flange<br />
dia.<br />
800 750 0-15 1,1 3,15 100 B5 250<br />
16-25 1,5 5,15 112 B5 250<br />
26-35 2,2 5,4 132 B5 250<br />
1000 0-13 2,2 5,4 112 B5 250<br />
14-22 3,0 7,4 132 B5 250<br />
23-31 4,0 9,2 132 B5 250<br />
32-35 5,5 12,7 132 B5 250<br />
1500 0-8 5,5 • 11,5 132 B5 250<br />
9-14 7,5 • 15,5 132 B5 250<br />
15-25 11 22 160 B5 350<br />
26-32 15 • 29,5 160 B5 350<br />
33-35 18,5 36 180 B5 350<br />
1000/500 0-12 1,85/0,33 4,6/1,6 112 B5 250<br />
13-25 3,3/0,75 9,3/3,6 132 B5 250<br />
26-35 4,4/1,1 11/4,4 132 B5 250<br />
1500/750 0-8 5,5/1,4 11,4/4,3 132 B5 250<br />
9-13 7,0/1,7 • 15/6,0 132 B5 250<br />
14-25 11/3,0 24/9,5 160 B5 350<br />
26-30 14/3,5 30,5/11,4 160 B5 350<br />
31-34 16/4,0 32,5/11,9 180 B5 350<br />
1500/1000 0-10 6,0/2,0 12,5/5,4 132 B5 250<br />
11-16 8,5/3,0 17,9/7,6 160 B5 350<br />
17-26 12/3,5 24/9,5 160 B5 350<br />
27-30 14/4,8 30/12 180 B5 350<br />
31-35 18/6,0 36/14 180 B5 350<br />
900 750 0-5 1,1 3,15 100 B5 250<br />
6-12 1,5 5,15 112 B5 250<br />
13-21 2,2 5,4 132 B5 250<br />
22-30 3,0 7,6 132 B5 250<br />
31-35 4,0 9,3 160 B5 350<br />
1000 0-8 3,0 7,4 132 B5 250<br />
9-14 4,0 9,2 132 B5 250<br />
15-22 5,5 12,7 132 B5 250<br />
23-31 7,5 15,7 160 B5 350<br />
32-35 11 22 160 B5 350<br />
1500 0-10 11 22 160 B5 350<br />
11-17 15 • 29,5 160 B5 350<br />
18-22 18,5 36 180 B5 350<br />
23-26 22 43 180 B5 350<br />
27-35 30 52 200 B5 350<br />
1000/500 0-10 3,3/0,75 9,3/3,6 132 B5 250<br />
11-16 4,4/1,1 11/4,4 132 B5 250<br />
17-26 6,3/1,5 15,7/5,4 160 B5 350<br />
27-35 8,8/2,2 20,5/7,0 160 B5 350
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
� Nominal current = appr. values for 400 V motors, brand EMOD. Brands<br />
ATB and Loher marked (A) and (L) respectively. It is impöortant to check nominal<br />
current in case of other motor brands.*ATB motors<br />
AXIAL FLOW FANS<br />
TECHNICAL LISTS (AVAILABLE MODELS)<br />
AXN 12/56 SERIES<br />
Flange<br />
dia.<br />
900 1500/750 0-10 11/3,0 24/9,5 160 B5 350<br />
11-15 14/3,5 30,5/11,4 160 B5 350<br />
16-18 16/4,0 32,5/11,9 180 B5 350<br />
19-25 20/5,5 39/16,2 180 B5 350<br />
26-35 28/7,0 52/16,2 200 B5 350<br />
1500/1000 0-11 12/3,5 24/9,5 160 B5 350<br />
12-15 14/4,8 30/12 180 B5 350<br />
16-22 18/6,0 36/14 180 B5 350<br />
23-25 20/7,0 41/16,2 200 B5 350<br />
26-30 25/9,0 47/18,5 200 B5 350<br />
31-35 33/11 61/24 225 B5 450<br />
1000 750 0-7 2,2 5,40 132 B5 250<br />
8-15 3,0 7,60 132 B5 250<br />
16-21 4,0 9,20 160 B5 350<br />
22-30 5,5 11,40 160 B5 350<br />
31-35 7,5 16,10 160 B5 350<br />
1000 0-10 5,5 12,70 132 B5 250<br />
11-17 7,5 15,70 160 B5 350<br />
18-27 11 22,00 160 B5 350<br />
28-35 15 29,50 180 B5 350<br />
1500 0-3 15 • 29,50 160 B5 350<br />
4-7 18,5 36,00 180 B5 350<br />
8-13 22 43,00 180 B5 350<br />
14-21 30 52,00 200 B5 350<br />
22-25 37 66,00 225 B5 450<br />
26-30 45 82,00 225 B5 450<br />
1000/500 0-7 4,4/1,0 11/4,4 132 B5 250<br />
8-13 6,3/1,5 15,7/5,4 160 B5 350<br />
14-22 8,8/2,2 20,5/7,0 160 B5 350<br />
23-30 12,5/3,0 32,5/11 180 B5 350<br />
31-35 18,5/4,4 40/13,3 200 B5 350<br />
1500/750 0-6 16/4,0 32,5/11,9 180 B5 350<br />
7-10 20/5,5 39/16,2 180 B5 350<br />
11-18 28/7,0 52/16,2 200 B5 350<br />
19-23 32/8,0 60/19 225 B5 450<br />
24-25 37/10 69/24,5 225 B5 450<br />
1500/1000 0-7 18/6,0 36/14 180 B5 350<br />
8-10 20/7,0 41/16,2 200 B5 350<br />
1120 750 0-5 4,0 9,3 160 B5 350<br />
6-13 5,5 11,4 160 B5 350<br />
14-21 7,5 16,1 160 B5 350<br />
22-27 11 23,5 180 B5 350<br />
28-35 15 31 200 B5 400<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
085<br />
Flange<br />
dia.<br />
1120 1000 0-2 7,5 15,7 160 B5 350<br />
3-9 11 22 160 B5 350<br />
10-14 15 29,5 180 B5 350<br />
15-20 18,5(L) 36 200 B5 400<br />
21-23 20 40 200 B5 400<br />
24-25 22 43 200 B5 400<br />
26-34 30 57 225 B5 450<br />
1000/500 0-1 6,3/1,5 15,7/5,4 160 B5 350<br />
2-44 8,8/2,2 20,5/7,0 160 B5 350<br />
55-12 12,5/3,0 32,5/11 180 B5 350<br />
13-16 15,5/3,3 34/11 200 B5 400<br />
17-20 18,5/4,4 40/13,3 200 B5 400<br />
1500 0-4 30 52 200 B5 400<br />
5-10 37 66 225 B5 450<br />
11-14 45 82 225 B5 450<br />
15-20 55(L) 97 250 B5 550<br />
21-27 75(L) 132 280 B5 550<br />
28-32 90(L) 157 280 B5 550<br />
1500/750 0-5 32/8,0 60/19 225 B5 450<br />
6-10 37/10 69/24,5 225 B5 450<br />
11-14 44/11(L) 78/24 225 B5 450<br />
15-23 68/17(L) 125/43,5 280 B5 550<br />
24-28 80/20(L) 140/48 280 B5 550<br />
1250 750 0-1 5,5 11,4 160 B5 350<br />
2-6 7,5 16,1 160 B5 350<br />
7-14 11 23,5 180 B5 350<br />
15-21 15 31 200 B5 400<br />
22-28 18,5 37 225 B5 450<br />
29-35 22 44,5 225 B5 450<br />
1000 0-3 15 29,5 180 B5 350<br />
4-10 20 40 200 B5 400<br />
11-15 22 43 200 B5 400<br />
16-20 30 57 225 B5 450<br />
21-32 45 85 280 B5 550<br />
1500 0-1 45 82 225 B5 450<br />
2-5 55(L) 97 250 B5 550<br />
6-13 75(L) 132 280 B5 550<br />
14-16 90(L) 157 280 B5 550<br />
17-22 110(L) 200 315<br />
23-26 132(L) 240 315<br />
auf<br />
Anfrage<br />
27-32 160(L)) 285 315<br />
1500/750 0-1 44/11(L) 78/24 225 B5 450<br />
2-3 49/11(L) 84/23 250 B5 550<br />
4-10 68/17(L) 125/43,5 280 B5 550<br />
11-15 80/20(L) 140/48 280 B5 550<br />
Technical Lists
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Fan Motor 400 V, 50 Hz<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
AXIAL FLOW FANS<br />
TECHNICAL LISTS (AVAILABLE MODELS)<br />
AXN 12/56 SERIES<br />
Flange<br />
dia.<br />
1400 750 0-3 11 23,5 180 B5 350<br />
4-10 15 31 200 B3<br />
11-13 18,5 37 225 B3<br />
14-18 22 44,5 225 B3<br />
19-27 30(L) 60 250 B3<br />
28-35 45(L) 88 280 B3<br />
1000 0-4 30 57 225 B3<br />
5-10 37(L) 74 250 B3<br />
11-14 45(L) 81 280 B3<br />
15-20 55(L) 99 280 B3<br />
21-27 75(L) 136 315 B3<br />
28-35 90(L) 160 315 B3<br />
1000/500 0-1 27/6,0(L) 51/18 225 B3<br />
2-4 30/7,0(L) 58/19 250 B3<br />
5-11 40/8,0(L) 74/24 280 B3<br />
12-15 48/9,5(L) 88/28 280 B3<br />
16-21 60/12(L) 106/22 315 B3<br />
22-24 70/14(L) 125/33 315 B3<br />
1600 750 0-3 22 44,5 225 B3<br />
4-11 30(L) 60 250 B3<br />
12-16 37(L) 73 280 B3<br />
17-21 45(L) 88 280 B3<br />
22-27 55(L) 110 315 B3<br />
1000 0-1 45(L) 81 280 B3<br />
2-7 55(L) 97 280 B3<br />
8-13 75(L) 138 315 B3<br />
14-17 90(L) 160 315 B3<br />
18-23 110(L) 195 315 B3<br />
1000/500 0-2 48/9,5(L) 88/28 280 B3<br />
3-9 60/12(L) 106/22 315 B3<br />
10-13 70/14(L) 125/33 315 B3<br />
14-16 85/16(L) 150/37 315 B3<br />
17-22 105/20(L) 185/47 315 B3<br />
� Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.<br />
It is impöortant to check nominal current in case of other motor brands.*ATB motors<br />
086
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Fan Motor 400 V, 50 Hz - explosion-proof<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
AXIAL FLOW FANS<br />
TECHNICAL LISTS (AVAILABLE MODELS)<br />
AXN 12/56 SERIES with explosion-proof motors<br />
Flange<br />
dia.<br />
250 3000 0-20 0,25 0,77 63 B14 120<br />
21-30 0,37 0,95 71 B14 120<br />
31-35 0,55 1,28 71 B14 120<br />
280 3000 0-10 0,25 0,77 63 B14 120<br />
11-20 0,37 0,95 71 B14 120<br />
21-30 0,55 1,28 71 B14 120<br />
31-35 0,75 1,74 80 B14 120<br />
315 1500 0-35 0,25 0,81 71 B5 160<br />
3000 0-13 0,55 1,28 71 B5 160<br />
14-20 0,75 1,74 80 B14 160<br />
21-31 1,0 2,4 80 B14 160<br />
355 1500 0-32 0,25 0,81 71 B5 160<br />
33-35 0,37 1,1 71 B5 160<br />
3000 0-7 0,75 1,74 80 B14 160<br />
8-15 1,0 2,4 80 B14 160<br />
16-25 1,5 3,1 90 B14 160<br />
26-35 1,85 3,8 90 B14 160<br />
400 1500 0-20 0,25 0,81 71 B5 160<br />
21-30 0,37 1,1 71 B5 160<br />
31-35 0,55 1,43 80 B5 200<br />
3000 0-10 1,5 3,1 90 B5 200<br />
11-114 1,85 3,8 90 b5 200<br />
15-21 2,5 4,65 100 B14 200<br />
22-28 3,3 6,7 112 B14 200<br />
450 1500 0-22 0,55 1,43 80 B5 200<br />
23-31 0,75 1,9 80 B5 200<br />
32-35 1,1 2,75 90 B5 200<br />
3000 0-14 3,3 6,7 112 B14 200<br />
500 1000 0-35 0,55 1,57 80 B5 200<br />
1500 0-15 0,75 1,9 80 B5 200<br />
16-25 1,1 2,75 90 B5 200<br />
3000 0-7 4,6 9,5 132 B5 250<br />
8-12 5,5 10,5 132 B5 250<br />
Fan Motor 400 V, 50 Hz - explosion-proof<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
� Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.<br />
It is impöortant to check nominal current in case of other motor brands.*ATB motors<br />
087<br />
Flange<br />
dia.<br />
560 1000 0-26 0,55 1,57 80 B5 200<br />
27-35 0,75 2,1 90 B5 200<br />
1500 0-13 1,1 2,75 90 B5 200<br />
14-20 1,5 3,5 90 B5 200<br />
21-30 2,1 4,75 100 B5 250<br />
31-34 2,6 5,8 100 B5 250<br />
630 750 0-35 0,55 1,71 90 B5 200<br />
1000 0-12 0,55 1,57 80 B5 200<br />
13-30 1,0 2,75 90 B5 200<br />
31-35 1,5 3,9 100 B5 250<br />
1500 0-6 1,5 3,5 90 B5 200<br />
7-15 2,1 4,75 100 B5 250<br />
16-20 2,6 5,8 100 B5 250<br />
21-30 4,0 8,2 112 B5 250<br />
31-35 5,5 10,9 132 B5 250<br />
710 750 0-17 0,55 1,71 90 B5 200<br />
18-22 0,65 1,9 100 B5 250<br />
23-32 0,95 2,85 100 B5 250<br />
1000 0-19 1,5 3,9 100 B5 250<br />
20-30 2,2 4,9 112 B5 250<br />
31-35 3,0 7,4 132 B5 250<br />
1500 0-13 4,0 8,2 112 B5 250<br />
14-20 5,5 10,9 132 B5 250<br />
21-28 7,5 15,4 132 B5 250<br />
800 750 0-13 0,95 2,85 100 B5 50<br />
14-22 1,3 4,0 112 B5 250<br />
23-32 1,9 5,0 132 B5 250<br />
1000 0-13 2,2 4,9 112 B5 250<br />
14-22 3,0 7,4 132 B5 250<br />
23-35 4,8 11,4 132 B5 250<br />
1500 0-8 5,5 10,9 132 B5 250<br />
9-14 7,5 15,4 132 B5 250<br />
15-24 10 19,2 160 B5 350<br />
25-29 13,5 25 160 B5 350<br />
30-32 15 28,5 180 B5 350<br />
33-35 17,5 32,5 180 B5 350<br />
Technical Lists
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Fan Motor 400 V, 50 Hz - explosion-proof<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
AXIAL FLOW FANS<br />
TECHNICAL LISTS (AVAILABLE MODELS)<br />
AXN 12/56 SERIES with explosion-proof motors<br />
Flange<br />
dia.<br />
900 750 0-9 1,3 4,0 112 B5 250<br />
10-19 1,9 5,0 132 B5 250<br />
20-22 2,6 6,75 132 B5 250<br />
23-35 3,5 8,4 132 B5 250<br />
1000 0-8 3,0 7,4 132 B5 250<br />
9-20 4,8 11,4 132 B5 250<br />
21-27 6,6 14,7 160 B5 350<br />
28-35 9,7 18,2 160 B5 350<br />
1500 0-12 13,5 25 160 B5 350<br />
13-17 15 28,5 180 B5 350<br />
18-21 17,5 32,5 180 B5 350<br />
22-28 24 42 200 B5 350<br />
29-35 29 50 225 B5 350<br />
1000 750 0-10 2,6 6,75 132 B5 250<br />
11-18 3,5 8,4 132 B5 250<br />
19-27 4,8 10,6 160 B5 350<br />
1000 0-6 4,8 11,4 132 B5 250<br />
7-14 6,6 14,7 160 B5 350<br />
15-23 9,7 18,2 160 B5 350<br />
24-33 13,2 26,6 180 B5 350<br />
1500 0-3 15 28,5 180 B5 350<br />
4-6 17,5 32,5 180 B5 350<br />
7-14 24 42 200 B5 350<br />
15-20 29 50 225 B5 450<br />
21-25 36 62 225 B5 450<br />
1120 750 0-12 4,8 10,6 160 B5 350<br />
13-18 6,6 15 160 B5 350<br />
19-26 9,7 20 180 B5 350<br />
27-35 13,2 28 200 B5 400<br />
1000 0-1 6,6 14,7 160 B5 350<br />
2-6 9,7 18,2 160 B5 350<br />
7-13 13,2 26,6 180 B5 350<br />
14-18 16,5 33,5 200 B5 400<br />
19-23 20 39 200 B5 400<br />
1500 0-4 29 50 225 B5 450<br />
5-10 36 62 225 B5 450<br />
Fan Motor 400 V, 50 Hz - explosion-proof<br />
Size<br />
Nominal Blade pitche<br />
speed angle<br />
[rpm] (black curve)<br />
Output<br />
[kW]<br />
Nominal<br />
current [A]<br />
�<br />
Size Type<br />
� Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.<br />
It is impöortant to check nominal current in case of other motor brands.*ATB motors<br />
088<br />
Flange<br />
dia.<br />
1250 750 0-1 5,5 12,2 160 B5 350<br />
2-5 6,6 15 160 B5 350<br />
6-12 9,7 20 180 B5 350<br />
13-20 13,2 28 200 B5 400<br />
21-26 16,5 36 225 B5 450<br />
27-32 20 43 225 B5 450<br />
1000 0-1 13,2 26,6 180 B5 350<br />
2-5 16,5 33,5 200 B5 400<br />
6-10 20 39 200 B5 400<br />
11-17 27 47,5 225 B5 450
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s30.ai<br />
5°<br />
0°<br />
710<br />
0,2<br />
4,0<br />
10<br />
5,6<br />
20<br />
0,39<br />
800<br />
0,224<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
900<br />
0,25<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,49<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/250/D*<br />
ROTATIONAL SPEED 2800 RPM<br />
Tip speed u 2 = 37 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
1 000<br />
0,28<br />
5,6<br />
20<br />
8,0<br />
40<br />
1 120<br />
0,315<br />
6,3<br />
25<br />
9,0<br />
50<br />
0,54<br />
1 250<br />
0,355<br />
7,1<br />
31,5<br />
10<br />
63<br />
1 400<br />
0,4<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,57<br />
1 600<br />
0,45<br />
9,0<br />
50<br />
12,5<br />
100<br />
1 800<br />
0,5<br />
10<br />
63<br />
14<br />
125<br />
Moment of inertia I = 0.0025 kg m 2<br />
Casing diameter d.i.L. = 254 mm<br />
Outlet cross section A 2 = 0.05 m 2<br />
2 000<br />
0,56<br />
11,2<br />
80<br />
16<br />
160<br />
� = 0,48<br />
0° 0° 5° 5° 10° 10° 15° 20° 25°<br />
15°<br />
15°<br />
20°<br />
0,45<br />
pd<br />
25°<br />
2 240<br />
0,63<br />
12,5<br />
100<br />
18<br />
200<br />
0,30<br />
2 500<br />
0,71<br />
14<br />
125<br />
20<br />
250<br />
0,40<br />
2 800<br />
0,8<br />
16<br />
160<br />
22,4<br />
315<br />
pd<br />
89<br />
88<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
81<br />
80<br />
79<br />
089<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 0,035 m 2<br />
35°<br />
Total acoustic powerlevel L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s31.ai<br />
5°<br />
0°<br />
0,46<br />
1 000<br />
0,28<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
1 120<br />
0,315<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,56<br />
1 250<br />
0,355<br />
5,6<br />
20<br />
8,0<br />
40<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/280/D*<br />
ROTATIONAL SPEED 2780 RPM 2D08031<br />
Tip speed u 2 = 41 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,61<br />
1 400<br />
0,4<br />
6,3<br />
25<br />
9,0<br />
50<br />
1 600<br />
0,45<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,66<br />
1 800<br />
0,5<br />
8,0<br />
40<br />
11,2<br />
80<br />
2 000<br />
0,56<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,69<br />
2 240<br />
0,63<br />
10<br />
63<br />
14<br />
125<br />
2 500<br />
0,71<br />
11,2<br />
80<br />
16<br />
160<br />
15°<br />
Moment of inertia I = 0.0045 kg m 2<br />
Casing diameter d.i.L. = 286 mm<br />
Outlet cross section A 2 = 0.064 m 2<br />
2 800<br />
0,8<br />
12,5<br />
100<br />
18<br />
200<br />
20°<br />
� = 0,60<br />
0,37<br />
10°<br />
0° 0° 5° 5° 10° 15° 20°<br />
10°<br />
15°<br />
3 150<br />
0,9<br />
14<br />
125<br />
20<br />
250<br />
0,57<br />
pd<br />
25°<br />
0,47<br />
25°<br />
3 550<br />
1,0<br />
16<br />
160<br />
22,4<br />
315<br />
0,52<br />
4 000<br />
1,12<br />
18<br />
200<br />
25<br />
400<br />
pd<br />
92<br />
91<br />
90<br />
89<br />
88<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
090<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0,044 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
40<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s32.ai<br />
5°<br />
0°<br />
630<br />
0,18<br />
2,24<br />
3,15<br />
3,15<br />
6,3<br />
710<br />
0,2<br />
2,5<br />
4,0<br />
3,55<br />
8,0<br />
0,36<br />
800<br />
0,224<br />
2,8<br />
5,0<br />
4,0<br />
10<br />
0,41<br />
Tip speed u 2 = 23 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
900<br />
0,25<br />
3,15<br />
6,3<br />
4,5<br />
12,5<br />
1 000<br />
0,28<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
0,46<br />
1 120<br />
0,315<br />
4,0<br />
10<br />
5,6<br />
20<br />
1 250<br />
0,355<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
0,49<br />
1 400<br />
0,4<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
1 600<br />
0,45<br />
5,6<br />
20<br />
8,0<br />
40<br />
Moment of inertia I = 0,007 kg m 2<br />
Casing diameter d.i.L. = 320 mm<br />
Outlet cross section A 2 = 0.08 m 2<br />
1 800<br />
0,5<br />
6,3<br />
25<br />
9,0<br />
50<br />
� = 0,40<br />
15°<br />
0° 0° 5° 5° 10° 10° 15° 20° 25°<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/315/D*<br />
ROTATIONAL SPEED 1360 RPM<br />
15°<br />
20°<br />
2 000<br />
0,56<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,37<br />
pd<br />
25°<br />
0,27<br />
2 240<br />
0,63<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,32<br />
2 500<br />
0,71<br />
9,0<br />
50<br />
12,5<br />
100<br />
pd<br />
83<br />
82<br />
81<br />
80<br />
79<br />
78<br />
77<br />
76<br />
75<br />
74<br />
73<br />
091<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.055 m 2<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
0,52<br />
5°<br />
0°<br />
1 600<br />
0,45<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,62<br />
1 800<br />
0,5<br />
6,3<br />
25<br />
9,0<br />
50<br />
2 000<br />
0,56<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,67<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/315/D*<br />
ROTATIONAL SPEED 2800 RPM 2D08033<br />
Tip speed u 2 = 47 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
2 240<br />
0,63<br />
8,0<br />
40<br />
11,2<br />
80<br />
2 500<br />
0,71<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,72<br />
2 800<br />
0,8<br />
10<br />
63<br />
14<br />
125<br />
3 150<br />
0,9<br />
11,2<br />
80<br />
16<br />
160<br />
0,75<br />
3 550<br />
1,0<br />
12,5<br />
100<br />
18<br />
200<br />
15°<br />
0,33<br />
4 000<br />
1,12<br />
14<br />
125<br />
20<br />
250<br />
Moment of inertia I = 0,007 kg m 2<br />
Casing diameter d.i.L. = 320 mm<br />
Outlet cross section A 2 = 0.08 m 2<br />
20°<br />
4 500<br />
1,25<br />
16<br />
160<br />
22,4<br />
315<br />
� = 0,66<br />
0,43<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
15°<br />
0,63<br />
pd<br />
25°<br />
5 000<br />
1,4<br />
18<br />
200<br />
25<br />
400<br />
0,53<br />
25°<br />
5 600<br />
1,6<br />
20<br />
250<br />
28<br />
500<br />
0,58<br />
30°<br />
6 300<br />
1,8<br />
22,4<br />
315<br />
31,5<br />
630<br />
pd<br />
97<br />
96<br />
95<br />
94<br />
93<br />
92<br />
91<br />
90<br />
89<br />
88<br />
87<br />
092<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
upon auf Anfrage request<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.055 m 2<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s34.ai<br />
5°<br />
0°<br />
0,32<br />
900<br />
0,25<br />
2,5<br />
4,0<br />
3,55<br />
8,0<br />
1 000<br />
0,28<br />
2,8<br />
5,0<br />
4,0<br />
10<br />
0,42<br />
1 120<br />
0,315<br />
3,15<br />
6,3<br />
4,5<br />
12,5<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/355/D*<br />
ROTATIONAL SPEED 1360 RPM<br />
Tip speed u 2 = 26 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,47<br />
1 250<br />
0,355<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
1 400<br />
0,4<br />
4,0<br />
10<br />
5,6<br />
20<br />
1 600<br />
0,45<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
0,52<br />
1 800<br />
0,5<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,55<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
2 000<br />
0,56<br />
5,6<br />
20<br />
8,0<br />
40<br />
2 240<br />
0,63<br />
6,3<br />
25<br />
9,0<br />
50<br />
15°<br />
Moment of inertia I = 0.014 kg m 2<br />
Casing diameter d.i.L. = 359 mm<br />
Outlet cross section A 2 = 0.10 m 2<br />
2 500<br />
0,71<br />
7,1<br />
31,5<br />
10<br />
63<br />
20°<br />
� = 0,46<br />
0,23<br />
2 800<br />
0,8<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,43<br />
pd<br />
25°<br />
0,33<br />
3 150<br />
0,9<br />
9,0<br />
50<br />
12,5<br />
100<br />
25°<br />
0,38<br />
3 550<br />
1,0<br />
10<br />
63<br />
14<br />
125<br />
pd<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
81<br />
80<br />
79<br />
78<br />
77<br />
093<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.07 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,56<br />
2 240<br />
0,63<br />
6,3<br />
25<br />
9,0<br />
50<br />
2 500<br />
0,71<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,66<br />
2 800<br />
0,8<br />
8,0<br />
40<br />
11,2<br />
80<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/355/D*<br />
ROTATIONAL SPEED 2820 RPM<br />
2D08035<br />
0,71<br />
Tip speed u 2 = 52 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
3 150<br />
0,9<br />
9,0<br />
50<br />
12,5<br />
100<br />
3 550<br />
1,0<br />
10<br />
63<br />
14<br />
125<br />
0,76<br />
4 000<br />
1,12<br />
11,2<br />
80<br />
16<br />
160<br />
4 500<br />
1,25<br />
12,5<br />
100<br />
18<br />
200<br />
0,79<br />
5 000<br />
1,4<br />
14<br />
125<br />
20<br />
250<br />
5 600<br />
1,6<br />
16<br />
160<br />
22,4<br />
315<br />
15°<br />
0,37<br />
Moment of inertia I = 0.014 kg m 2<br />
Casing diameter d.i.L. = 359 mm<br />
Outlet cross section A 2 = 0.10 m 2<br />
6 300<br />
1,8<br />
18<br />
200<br />
25<br />
400<br />
20°<br />
0,47<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
15°<br />
� = 0,70<br />
7 100<br />
2,0<br />
20<br />
250<br />
28<br />
500<br />
0,67<br />
pd<br />
25°<br />
0,57<br />
25°<br />
8 000<br />
2,24<br />
22,4<br />
315<br />
31,5<br />
630<br />
0,62<br />
9 000<br />
2,5<br />
25<br />
400<br />
35,5<br />
800<br />
pd<br />
101<br />
100<br />
99<br />
98<br />
97<br />
96<br />
95<br />
94<br />
93<br />
92<br />
91<br />
094<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.07 m 2<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,43<br />
1 400<br />
0,4<br />
3,15<br />
6,3<br />
4,5<br />
12,5<br />
1 600<br />
0,45<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
0,53<br />
1 800<br />
0,5<br />
4,0<br />
10<br />
5,6<br />
20<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/400/D*<br />
ROTATIONAL SPEED 1360 RPM<br />
Tip speed u 2 = 28 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,58<br />
2 000<br />
0,56<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
2 240<br />
0,63<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,63<br />
2 500<br />
0,71<br />
5,6<br />
20<br />
8,0<br />
40<br />
2 800<br />
0,8<br />
6,3<br />
25<br />
9,0<br />
50<br />
0,66<br />
3 150<br />
0,9<br />
7,1<br />
31,5<br />
10<br />
63<br />
3 550<br />
1,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
15°<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
15°<br />
Moment of inertia I = 0.024 kg m 2<br />
Casing diameter d.i.L. = 401 mm<br />
Outlet cross section A 2 = 0.126 m 2<br />
4 000<br />
1,12<br />
9,0<br />
50<br />
12,5<br />
100<br />
20°<br />
� = 0,57<br />
0,34<br />
4 500<br />
1,25<br />
10<br />
63<br />
14<br />
125<br />
0,54<br />
pd<br />
25°<br />
0,44<br />
25°<br />
5 000<br />
1,4<br />
11,2<br />
80<br />
16<br />
160<br />
0,49<br />
5 600<br />
1,6<br />
12,5<br />
100<br />
18<br />
200<br />
pd<br />
89<br />
88<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
81<br />
80<br />
79<br />
095<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0.087 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,50<br />
3 150<br />
0,9<br />
7,1<br />
31,5<br />
10<br />
63<br />
3 550<br />
1,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,60<br />
4 000<br />
1,12<br />
9,0<br />
50<br />
12,5<br />
100<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/400/D*<br />
ROTATIONAL SPEED 2895 RPM<br />
2D08037<br />
Tip speed u 2 = 59 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,70<br />
4 500<br />
1,25<br />
10<br />
63<br />
14<br />
125<br />
5 000<br />
1,4<br />
11,2<br />
80<br />
16<br />
160<br />
0,75<br />
5 600<br />
1,6<br />
12,5<br />
100<br />
18<br />
200<br />
6 300<br />
1,8<br />
14<br />
125<br />
20<br />
250<br />
0,83<br />
7 100<br />
2,0<br />
16<br />
160<br />
22,4<br />
315<br />
8 000<br />
2,24<br />
18<br />
200<br />
25<br />
400<br />
15°<br />
0,41<br />
Moment of inertia I = 0.024 kg m 2<br />
Casing diameter d.i.L. = 401 mm<br />
Outlet cross section A 2 = 0.126 m 2<br />
9 000<br />
2,5<br />
20<br />
250<br />
28<br />
500<br />
20°<br />
� = 0,74<br />
0,51<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
10°<br />
15°<br />
10 000<br />
2,8<br />
22,4<br />
315<br />
31,5<br />
630<br />
0,71<br />
pd<br />
25°<br />
0,61<br />
25°<br />
11 200<br />
3,15<br />
25<br />
400<br />
35,5<br />
800<br />
0,66<br />
12 500<br />
3,55<br />
28<br />
500<br />
40<br />
1000<br />
pd<br />
103<br />
102<br />
101<br />
100<br />
99<br />
98<br />
97<br />
96<br />
95<br />
94<br />
93<br />
096<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0.087 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s38.ai<br />
0,52<br />
5°<br />
0°<br />
2 240<br />
0,63<br />
4,0<br />
10<br />
5,6<br />
20<br />
0,62<br />
2 500<br />
0,71<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
2 800<br />
0,8<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
10°<br />
0,67<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/450/D*<br />
ROTATIONAL SPEED 1400 RPM<br />
Tip speed u 2 = 33 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
3 150<br />
0,9<br />
5,6<br />
20<br />
8,0<br />
40<br />
3 550<br />
1,0<br />
6,3<br />
25<br />
9,0<br />
50<br />
0,72<br />
4 000<br />
1,12<br />
7,1<br />
31,5<br />
10<br />
63<br />
4 500<br />
1,25<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,75<br />
5 000<br />
1,4<br />
9,0<br />
50<br />
12,5<br />
100<br />
15°<br />
0,33<br />
5 600<br />
1,6<br />
10<br />
63<br />
14<br />
125<br />
Moment of inertia I = 0.041 kg m 2<br />
Casing diameter d.i.L. = 450 mm<br />
Outlet cross section A 2 = 0.159 m 2<br />
20°<br />
6 300<br />
1,8<br />
11,2<br />
80<br />
16<br />
160<br />
� = 0,66<br />
0,43<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
15°<br />
0,63<br />
pd<br />
25°<br />
0,53<br />
7 100<br />
2,0<br />
12,5<br />
100<br />
18<br />
200<br />
25°<br />
8 000<br />
2,24<br />
14<br />
125<br />
20<br />
250<br />
0,58<br />
pd<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
9 000<br />
2,5<br />
16<br />
160<br />
22,4<br />
315<br />
92<br />
91<br />
90<br />
89<br />
88<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
097<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.11 m 2<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s39.ai<br />
5°<br />
0°<br />
0,62<br />
4 500<br />
1,25<br />
8,0<br />
40<br />
11,2<br />
80<br />
5 000<br />
1,4<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,72<br />
5 600<br />
1,6<br />
10<br />
63<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/450/D*<br />
ROTATIONAL SPEED 2860 RPM<br />
2D08039<br />
Tip speed u 2 = 67 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,77<br />
6 300<br />
1,8<br />
11,2<br />
80<br />
16<br />
160<br />
7 100<br />
2,0<br />
12,5<br />
100<br />
18<br />
200<br />
0,82<br />
8 000<br />
2,24<br />
14<br />
125<br />
20<br />
250<br />
9 000<br />
2,5<br />
16<br />
160<br />
22,4<br />
315<br />
0,85<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
10 000<br />
2,8<br />
18<br />
200<br />
25<br />
400<br />
11 200<br />
3,15<br />
20<br />
250<br />
28<br />
500<br />
15°<br />
0,43<br />
Moment of inertia I = 0.041 kg m 2<br />
Casing diameter d.i.L. = 450 mm<br />
Outlet cross section A 2 = 0.159 m 2<br />
12 500<br />
3,55<br />
22,4<br />
315<br />
31,5<br />
630<br />
20°<br />
� = 0,76<br />
0,53<br />
14 000<br />
4,0<br />
25<br />
400<br />
35,5<br />
800<br />
0,73<br />
pd<br />
25°<br />
0,63<br />
25°<br />
16 000<br />
4,5<br />
28<br />
500<br />
40<br />
1000<br />
0,68<br />
18 000<br />
5,0<br />
31,5<br />
630<br />
45<br />
1250<br />
pd<br />
108<br />
107<br />
106<br />
105<br />
104<br />
103<br />
102<br />
101<br />
100<br />
99<br />
98<br />
098<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.11 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s40.ai<br />
0,46<br />
5°<br />
0°<br />
2 000<br />
0,56<br />
2,8<br />
5,0<br />
4,0<br />
10<br />
0,56<br />
2 240<br />
0,63<br />
3,15<br />
6,3<br />
4,5<br />
12,5<br />
2 500<br />
0,71<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
0,61<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/500/D*<br />
ROTATIONAL SPEED 910 RPM<br />
Tip speed u 2 = 24 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
2 800<br />
0,8<br />
4,0<br />
10<br />
5,6<br />
20<br />
3 150<br />
0,9<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
0,66<br />
3 550<br />
1,0<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,69<br />
4 000<br />
1,12<br />
5,6<br />
20<br />
8,0<br />
40<br />
4 500<br />
1,25<br />
6,3<br />
25<br />
9,0<br />
50<br />
15°<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
15°<br />
5 000<br />
1,4<br />
7,1<br />
31,5<br />
10<br />
63<br />
Moment of inertia I = 0.073 kg m 2<br />
Casing diameter d.i.L. = 504 mm<br />
Outlet cross section A 2 = 0.2 m 2<br />
20°<br />
� = 0,60<br />
0,37<br />
5 600<br />
1,6<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,57<br />
pd<br />
25°<br />
0,47<br />
6 300<br />
1,8<br />
9,0<br />
50<br />
12,5<br />
100<br />
25°<br />
7 100<br />
2,0<br />
10<br />
63<br />
14<br />
125<br />
0,52<br />
pd<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
8 000<br />
2,24<br />
11,2<br />
80<br />
16<br />
160<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
81<br />
80<br />
79<br />
78<br />
77<br />
099<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.14 m 2<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s41.ai<br />
0,57<br />
5°<br />
0°<br />
3 150<br />
0,9<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
0,67<br />
3 550<br />
1,0<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
4 000<br />
1,12<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,72<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/500/D*<br />
ROTATIONAL SPEED 1400 RPM<br />
2D08041<br />
Tip speed u 2 = 38 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
4 500<br />
1,25<br />
6,3<br />
25<br />
9,0<br />
50<br />
5 000<br />
1,4<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,77<br />
5 600<br />
1,6<br />
8,0<br />
40<br />
11,2<br />
80<br />
6 300<br />
1,8<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,80<br />
0° 0° 5° 5° 10° 10° 15°<br />
15°<br />
7 100<br />
2,0<br />
10<br />
63<br />
14<br />
125<br />
15°<br />
0,38<br />
8 000<br />
2,24<br />
11,2<br />
80<br />
16<br />
160<br />
Moment of inertia I = 0.073 kg m 2<br />
Casing diameter d.i.L. = 504 mm<br />
Outlet cross section A 2 = 0.2 m 2<br />
20°<br />
9 000<br />
2,5<br />
12,5<br />
100<br />
18<br />
200<br />
� = 0,71<br />
0,48<br />
0,68<br />
pd<br />
25°<br />
10 000<br />
2,8<br />
14<br />
125<br />
20<br />
250<br />
0,58<br />
25°<br />
11 200<br />
3,15<br />
16<br />
160<br />
22,4<br />
315<br />
0,63<br />
12 500<br />
3,55<br />
18<br />
200<br />
25<br />
400<br />
pd<br />
97<br />
96<br />
95<br />
94<br />
93<br />
92<br />
91<br />
90<br />
89<br />
88<br />
87<br />
100<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.14 m 2<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1800<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s42.ai<br />
5°<br />
0°<br />
0,64<br />
6 300<br />
1,8<br />
9,0<br />
50<br />
12,5<br />
100<br />
7 100<br />
2,0<br />
10<br />
63<br />
14<br />
125<br />
0,74<br />
8 000<br />
2,24<br />
11,2<br />
80<br />
16<br />
160<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/500/D*<br />
ROTATIONAL SPEED 2880 RPM<br />
Tip speed u 2 = 76 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,79<br />
9 000<br />
2,5<br />
12,5<br />
100<br />
18<br />
200<br />
10 000<br />
2,8<br />
14<br />
125<br />
20<br />
250<br />
11 200<br />
3,15<br />
16<br />
160<br />
22,4<br />
315<br />
0,84<br />
12 500<br />
3,55<br />
18<br />
200<br />
25<br />
400<br />
0,87<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
14 000<br />
4,0<br />
20<br />
250<br />
28<br />
500<br />
16 000<br />
4,5<br />
22,4<br />
315<br />
31,5<br />
630<br />
15°<br />
0,45<br />
Moment of inertia I = 0.073 kg m 2<br />
Casing diameter d.i.L. = 504 mm<br />
Outlet cross section A 2 = 0.2 m 2<br />
18 000<br />
5,0<br />
25<br />
400<br />
35,5<br />
800<br />
20°<br />
� = 0,78<br />
0,55<br />
20 000<br />
5,6<br />
28<br />
500<br />
40<br />
1000<br />
0,75<br />
pd<br />
25°<br />
0,65<br />
22 400<br />
6,3<br />
31,5<br />
630<br />
45<br />
1250<br />
25°<br />
0,70<br />
25 000<br />
7,1<br />
35,5<br />
800<br />
50<br />
1600<br />
pd<br />
110<br />
109<br />
108<br />
107<br />
106<br />
105<br />
104<br />
103<br />
102<br />
101<br />
100<br />
101<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.14 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input reqirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s43.ai<br />
5°<br />
0°<br />
0,53<br />
2 800<br />
0,8<br />
3,15<br />
6,3<br />
4,5<br />
12,5<br />
3 150<br />
0,9<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
0,63<br />
3 550<br />
1,0<br />
4,0<br />
10<br />
5,6<br />
20<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/560/D*<br />
ROTATIONAL SPEED 920 RPM<br />
2D08043<br />
0,68<br />
Tip speed u 2 = 27 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
4 000<br />
1,12<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
4 500<br />
1,25<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,73<br />
5 000<br />
1,4<br />
5,6<br />
20<br />
8,0<br />
40<br />
5 600<br />
1,6<br />
6,3<br />
25<br />
9,0<br />
50<br />
0,76<br />
0° 0° 5° 5° 10° 10° 15°<br />
15°<br />
6 300<br />
1,8<br />
7,1<br />
31,5<br />
10<br />
63<br />
7 100<br />
2,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
15°<br />
0,34<br />
Moment of inertia I = 0.12 kg m 2<br />
Casing diameter d.i.L. = 565 mm<br />
Outlet cross section A 2 = 0.25 m 2<br />
8 000<br />
2,24<br />
9,0<br />
50<br />
12,5<br />
100<br />
20°<br />
� = 0,67<br />
0,44<br />
9 000<br />
2,5<br />
10<br />
63<br />
14<br />
125<br />
0,64<br />
pd<br />
25°<br />
0,54<br />
25°<br />
10 000<br />
2,8<br />
11,2<br />
80<br />
16<br />
160<br />
0,59<br />
11 200<br />
3,15<br />
12,5<br />
100<br />
18<br />
200<br />
pd<br />
92<br />
91<br />
90<br />
89<br />
88<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
102<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.17 m 2<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s44.ai<br />
5°<br />
0°<br />
0,61<br />
4 500<br />
1,25<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
5 000<br />
1,4<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,71<br />
5 600<br />
1,6<br />
6,3<br />
25<br />
9,0<br />
50<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/560/D*<br />
ROTATIONAL SPEED 1400 RPM<br />
0,76<br />
Tip speed u 2 = 41 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
6 300<br />
1,8<br />
7,1<br />
31,5<br />
10<br />
63<br />
7 100<br />
2,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,81<br />
8 000<br />
2,24<br />
9,0<br />
50<br />
12,5<br />
100<br />
9 000<br />
2,5<br />
10<br />
63<br />
14<br />
125<br />
0,84<br />
0° 0° 5° 5° 10° 10° 15°<br />
15°<br />
10 000<br />
2,8<br />
11,2<br />
80<br />
16<br />
160<br />
15°<br />
0,42<br />
11 200<br />
3,15<br />
12,5<br />
100<br />
18<br />
200<br />
Moment of inertia I = 0.12 kg m 2<br />
Casing diameter d.i.L. = 565 mm<br />
Outlet cross section A 2 = 0.25 m 2<br />
12 500<br />
3,55<br />
14<br />
125<br />
20<br />
250<br />
20°<br />
� = 0,75<br />
0,52<br />
14 000<br />
4,0<br />
16<br />
160<br />
22,4<br />
315<br />
0,72<br />
pd<br />
25°<br />
0,62<br />
25°<br />
16 000<br />
4,5<br />
18<br />
200<br />
25<br />
400<br />
0,67<br />
18 000<br />
5,0<br />
20<br />
250<br />
28<br />
500<br />
pd<br />
99<br />
98<br />
97<br />
96<br />
95<br />
94<br />
93<br />
92<br />
91<br />
90<br />
89<br />
103<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.17 m 2<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,51<br />
2 800<br />
0,8<br />
2,5<br />
4,0<br />
3,55<br />
8,0<br />
3 150<br />
0,9<br />
2,8<br />
5,0<br />
4,0<br />
10<br />
0,61<br />
3 550<br />
1,0<br />
3,15<br />
6,3<br />
4,5<br />
12,5<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/630/D*<br />
ROTATIONAL SPEED 690 RPM<br />
Tip speed u 2 = 23 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,66<br />
4 000<br />
1,12<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
4 500<br />
1,25<br />
4,0<br />
10<br />
5,6<br />
20<br />
5 000<br />
1,4<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
0,71<br />
5 600<br />
1,6<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,74<br />
6 300<br />
1,8<br />
5,6<br />
20<br />
8,0<br />
40<br />
7 100<br />
2,0<br />
6,3<br />
25<br />
9,0<br />
50<br />
15°<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
10°<br />
15°<br />
Moment of inertia I = 0.223 kg m 2<br />
Casing diameter d.i.L. = 634 mm<br />
Outlet cross section A 2 = 0.31 m 2<br />
8 000<br />
2,24<br />
7,1<br />
31,5<br />
10<br />
63<br />
20°<br />
� = 0,65<br />
0,42<br />
0,32<br />
9 000<br />
2,5<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,62<br />
pd<br />
25°<br />
0,52<br />
10 000<br />
2,8<br />
9,0<br />
50<br />
12,5<br />
100<br />
25°<br />
0,57<br />
11 200<br />
3,15<br />
10<br />
63<br />
14<br />
125<br />
pd<br />
88<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
81<br />
80<br />
79<br />
78<br />
104<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0.22 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,57<br />
4 000<br />
1,12<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
4 500<br />
1,25<br />
4,0<br />
10<br />
5,6<br />
20<br />
0,67<br />
5 000<br />
1,4<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/630/D*<br />
ROTATIONAL SPEED 920 RPM<br />
Tip speed u 2 = 30 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,72<br />
5 600<br />
1,6<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
6 300<br />
1,8<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,77<br />
7 100<br />
2,0<br />
6,3<br />
25<br />
9,0<br />
50<br />
8 000<br />
2,24<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,80<br />
9 000<br />
2,5<br />
8,0<br />
40<br />
11,2<br />
80<br />
10 000<br />
2,8<br />
9,0<br />
50<br />
12,5<br />
100<br />
15°<br />
0,38<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
10°<br />
15°<br />
Moment of inertia I = 0.223 kg m 2<br />
Casing diameter d.i.L. = 634 mm<br />
Outlet cross section A 2 = 0.31 m 2<br />
11 200<br />
3,15<br />
10<br />
63<br />
14<br />
125<br />
20°<br />
� = 0,71<br />
0,48<br />
12 500<br />
3,55<br />
11,2<br />
80<br />
16<br />
160<br />
0,68<br />
pd<br />
25°<br />
0,58<br />
25°<br />
14 000<br />
4,0<br />
12,5<br />
100<br />
18<br />
200<br />
0,63<br />
16 000<br />
4,5<br />
14<br />
125<br />
20<br />
250<br />
pd<br />
92<br />
91<br />
90<br />
89<br />
88<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
105<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0.22 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,62<br />
6 300<br />
1,8<br />
5,6<br />
20<br />
8,0<br />
40<br />
7 100<br />
2,0<br />
6,3<br />
25<br />
9,0<br />
50<br />
0,72<br />
8 000<br />
2,24<br />
7,1<br />
31,5<br />
10<br />
63<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/630/D*<br />
ROTATIONAL SPEED 1400 RPM<br />
Tip speed u 2 = 46 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,77<br />
9 000<br />
2,5<br />
8,0<br />
40<br />
11,2<br />
80<br />
10 000<br />
2,8<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,82<br />
11 200<br />
3,15<br />
10<br />
63<br />
14<br />
125<br />
12 500<br />
3,55<br />
11,2<br />
80<br />
16<br />
160<br />
0,85<br />
14 000<br />
4,0<br />
12,5<br />
100<br />
18<br />
200<br />
16 000<br />
4,5<br />
14<br />
125<br />
20<br />
250<br />
15°<br />
0,43<br />
Moment of inertia I = 0.223 kg m 2<br />
Casing diameter d.i.L. = 634 mm<br />
Outlet cross section A 2 = 0.31 m 2<br />
18 000<br />
5,0<br />
16<br />
160<br />
22,4<br />
315<br />
20°<br />
� = 0,76<br />
0,53<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
10°<br />
15°<br />
20 000<br />
5,6<br />
18<br />
200<br />
25<br />
400<br />
0,73<br />
pd<br />
25°<br />
0,63<br />
25°<br />
22 400<br />
6,3<br />
20<br />
250<br />
28<br />
500<br />
0,68<br />
25 000<br />
7,1<br />
22,4<br />
315<br />
31,5<br />
630<br />
pd<br />
101<br />
100<br />
99<br />
98<br />
97<br />
96<br />
95<br />
94<br />
93<br />
92<br />
91<br />
106<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0.22 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,57<br />
4 500<br />
1,25<br />
3,15<br />
6,3<br />
4,5<br />
12,5<br />
5 000<br />
1,4<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
0,67<br />
5 600<br />
1,6<br />
4,0<br />
10<br />
5,6<br />
20<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/710/D*<br />
ROTATIONAL SPEED 700 RPM<br />
0,72<br />
Tip speed u 2 = 26 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
6 300<br />
1,8<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
7 100<br />
2,0<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,77<br />
8 000<br />
2,24<br />
5,6<br />
20<br />
8,0<br />
40<br />
9 000<br />
2,5<br />
6,3<br />
25<br />
9,0<br />
50<br />
0,80<br />
10 000<br />
2,8<br />
7,1<br />
31,5<br />
10<br />
63<br />
15°<br />
0° 0° 5° 5° 10° 10° 15° 20°<br />
10°<br />
15°<br />
11 200<br />
3,15<br />
8,0<br />
40<br />
11,2<br />
80<br />
Moment of inertia I = 0,40 kg m 2<br />
Casing diameter d.i.L. = 711 mm<br />
Outlet cross section A 2 = 0,39 m 2<br />
12 500<br />
3,55<br />
9,0<br />
50<br />
12,5<br />
100<br />
20°<br />
� = 0,71<br />
0,48<br />
0,38<br />
14 000<br />
4,0<br />
10<br />
63<br />
14<br />
125<br />
0,68<br />
pd<br />
25°<br />
0,58<br />
25°<br />
16 000<br />
4,5<br />
11,2<br />
80<br />
16<br />
160<br />
0,63<br />
18 000<br />
5,0<br />
12,5<br />
100<br />
18<br />
200<br />
pd<br />
92<br />
91<br />
90<br />
89<br />
88<br />
87<br />
86<br />
85<br />
84<br />
83<br />
82<br />
107<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 0,27 m 2<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input reqirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
5 600<br />
1,6<br />
4,0<br />
10<br />
5,6<br />
20<br />
0,61<br />
6 300<br />
1,8<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
0,71<br />
7 100<br />
2,0<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/710/D*<br />
ROTATIONAL SPEED 950 RPM<br />
Tip speed u 2 = 35 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
8 000<br />
2,24<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,76<br />
9 000<br />
2,5<br />
6,3<br />
25<br />
9,0<br />
50<br />
10 000<br />
2,8<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,81<br />
11 200<br />
3,15<br />
8,0<br />
40<br />
11,2<br />
80<br />
12 500<br />
3,55<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,84<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
14 000<br />
4,0<br />
10<br />
63<br />
14<br />
125<br />
Moment of inertia I = 0.40 kg m 2<br />
Casing diameter d.i.L. = 711 mm<br />
Outlet cross section A 2 = 0.4 m 2<br />
15°<br />
16 000<br />
4,5<br />
11,2<br />
80<br />
16<br />
160<br />
20°<br />
18 000<br />
5,0<br />
12,5<br />
100<br />
18<br />
200<br />
� = 0,75<br />
0,52<br />
0,42<br />
0,72<br />
pd<br />
25°<br />
20 000<br />
5,6<br />
14<br />
125<br />
20<br />
250<br />
0,62<br />
25°<br />
22 400<br />
6,3<br />
16<br />
160<br />
22,4<br />
315<br />
0,67<br />
pd<br />
99<br />
98<br />
97<br />
96<br />
95<br />
94<br />
93<br />
92<br />
91<br />
90<br />
89<br />
108<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.27 m 2<br />
35°<br />
30°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,64<br />
9 000<br />
2,5<br />
6,3<br />
25<br />
9,0<br />
50<br />
10 000<br />
2,8<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,74<br />
11 200<br />
3,15<br />
8,0<br />
40<br />
11,2<br />
80<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/710/D*<br />
ROTATIONAL SPEED 1430 RPM<br />
Tip speed u 2 = 53 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,79<br />
12 500<br />
3,55<br />
9,0<br />
50<br />
12,5<br />
100<br />
14 000<br />
4,0<br />
10<br />
63<br />
14<br />
125<br />
16 000<br />
4,5<br />
11,2<br />
80<br />
16<br />
160<br />
0,84<br />
18 000<br />
5,0<br />
12,5<br />
100<br />
18<br />
200<br />
0,87<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
20 000<br />
5,6<br />
14<br />
125<br />
20<br />
250<br />
22 400<br />
6,3<br />
16<br />
160<br />
22,4<br />
315<br />
15°<br />
0,45<br />
Moment of inertia I = 0.40 kg m 2<br />
Casing diameter d.i.L. = 711 mm<br />
Outlet cross section A 2 = 0.4 m 2<br />
25 000<br />
7,1<br />
18<br />
200<br />
25<br />
400<br />
20°<br />
� = 0,78<br />
0,55<br />
28 000<br />
8,0<br />
20<br />
250<br />
28<br />
500<br />
0,75<br />
pd<br />
25°<br />
0,65<br />
31 500<br />
9,0<br />
22,4<br />
315<br />
31,5<br />
630<br />
25°<br />
0,70<br />
35 500<br />
10<br />
25<br />
400<br />
35,5<br />
800<br />
pd<br />
106<br />
105<br />
104<br />
103<br />
102<br />
101<br />
100<br />
99<br />
98<br />
97<br />
96<br />
109<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.27 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,58<br />
6 300<br />
1,8<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
7 100<br />
2,0<br />
4,0<br />
10<br />
5,6<br />
20<br />
0,68<br />
8 000<br />
2,24<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/800/D*<br />
ROTATIONAL SPEED 720 RPM<br />
Tip speed u 2 = 30 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,73<br />
9 000<br />
2,5<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
10 000<br />
2,8<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,78<br />
11 200<br />
3,15<br />
6,3<br />
25<br />
9,0<br />
50<br />
12 500<br />
3,55<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,83<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
14 000<br />
4,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
16 000<br />
4,5<br />
9,0<br />
50<br />
12,5<br />
100<br />
15°<br />
0,41<br />
Moment of inertia I = 0.69 kg m 2<br />
Casing diameter d.i.L. = 797 mm<br />
Outlet cross section A 2 = 0.5 m 2<br />
18 000<br />
5,0<br />
10<br />
63<br />
14<br />
125<br />
20°<br />
� = 0,74<br />
0,51<br />
20 000<br />
5,6<br />
11,2<br />
80<br />
16<br />
160<br />
0,71<br />
pd<br />
25°<br />
0,61<br />
25°<br />
22 400<br />
6,3<br />
12,5<br />
100<br />
18<br />
200<br />
0,66<br />
25 000<br />
7,1<br />
14<br />
125<br />
20<br />
250<br />
pd<br />
96<br />
95<br />
94<br />
93<br />
92<br />
91<br />
90<br />
89<br />
88<br />
87<br />
86<br />
110<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.34 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
8 000<br />
2,24<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
0,63<br />
9 000<br />
2,5<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,73<br />
10 000<br />
2,8<br />
5,6<br />
20<br />
8,0<br />
40<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/800/D*<br />
ROTATIONAL SPEED 950 RPM<br />
Tip speed u 2 = 39 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
11 200<br />
3,15<br />
6,3<br />
25<br />
9,0<br />
50<br />
10°<br />
0,78<br />
12 500<br />
3,55<br />
7,1<br />
31,5<br />
10<br />
63<br />
14 000<br />
4,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
15°<br />
0,83<br />
16 000<br />
4,5<br />
9,0<br />
50<br />
12,5<br />
100<br />
18 000<br />
5,0<br />
10<br />
63<br />
14<br />
125<br />
20 000<br />
5,6<br />
11,2<br />
80<br />
16<br />
160<br />
Moment of inertia I = 0.69 kg m 2<br />
Casing diameter d.i.L. = 797 mm<br />
Outlet cross section A 2 = 0.5 m 2<br />
22 400<br />
6,3<br />
12,5<br />
100<br />
18<br />
200<br />
25 000<br />
7,1<br />
14<br />
125<br />
20<br />
250<br />
28 000<br />
8,0<br />
16<br />
160<br />
22,4<br />
315<br />
31 500<br />
9,0<br />
18<br />
200<br />
25<br />
400<br />
101<br />
100<br />
99<br />
98<br />
97<br />
96<br />
95<br />
94<br />
93<br />
92<br />
91<br />
111<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
0,86<br />
0° 0° 5° 5° 10° 10° 15°<br />
15°<br />
0,44<br />
20°<br />
� = 0,77<br />
0,54<br />
20°<br />
20°<br />
0,74<br />
pd<br />
25°<br />
0,64<br />
25°<br />
25°<br />
A 1 = 0.34 m 2<br />
0,69<br />
35°<br />
30°<br />
pd<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,65<br />
12 500<br />
3,55<br />
7,1<br />
31,5<br />
10<br />
63<br />
14 000<br />
4,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,75<br />
16 000<br />
4,5<br />
9,0<br />
50<br />
12,5<br />
100<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/800/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u 2 = 60 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
18 000<br />
5,0<br />
10<br />
63<br />
14<br />
125<br />
0,80<br />
20 000<br />
5,6<br />
11,2<br />
80<br />
16<br />
160<br />
22 400<br />
6,3<br />
12,5<br />
100<br />
18<br />
200<br />
0,85<br />
25 000<br />
7,1<br />
14<br />
125<br />
20<br />
250<br />
0,88<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
28 000<br />
8,0<br />
16<br />
160<br />
22,4<br />
315<br />
31 500<br />
9,0<br />
18<br />
200<br />
25<br />
400<br />
Moment of inertia I = 0.69 kg m 2<br />
Casing diameter d.i.L. = 797 mm<br />
Outlet cross section A 2 = 0.5 m 2<br />
15°<br />
0,46<br />
35 500<br />
10<br />
20<br />
250<br />
28<br />
500<br />
20°<br />
� = 0,79<br />
0,56<br />
40 000<br />
11,2<br />
22,4<br />
315<br />
31,5<br />
630<br />
0,76<br />
pd<br />
25°<br />
0,66<br />
45 000<br />
12,5<br />
25<br />
400<br />
35,5<br />
800<br />
25°<br />
50 000<br />
14<br />
28<br />
500<br />
40<br />
1000<br />
0,71<br />
pd<br />
110<br />
109<br />
108<br />
107<br />
106<br />
105<br />
104<br />
103<br />
102<br />
101<br />
100<br />
112<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.34 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,63<br />
9 000<br />
2,5<br />
4,0<br />
10<br />
5,6<br />
20<br />
10 000<br />
2,8<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
0,73<br />
11 200<br />
3,15<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/900/D*<br />
ROTATIONAL SPEED 720 RPM<br />
Tip speed u 2 = 33 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,78<br />
12 500<br />
3,55<br />
5,6<br />
20<br />
8,0<br />
40<br />
14 000<br />
4,0<br />
6,3<br />
25<br />
9,0<br />
50<br />
16 000<br />
4,5<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,83<br />
18 000<br />
5,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,86<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
20 000<br />
5,6<br />
9,0<br />
50<br />
12,5<br />
100<br />
22 400<br />
6,3<br />
10<br />
63<br />
14<br />
125<br />
15°<br />
0,44<br />
Moment of inertia I = 1.20 kg m 2<br />
Casing diameter d.i.L. = 894 mm<br />
Outlet cross section A 2 = 0.63 m 2<br />
25 000<br />
7,1<br />
11,2<br />
80<br />
16<br />
160<br />
20°<br />
� = 0,77<br />
0,54<br />
28 000<br />
8,0<br />
12,5<br />
100<br />
18<br />
200<br />
0,74<br />
pd<br />
25°<br />
0,64<br />
31 500<br />
9,0<br />
14<br />
125<br />
20<br />
250<br />
25°<br />
0,69<br />
35 500<br />
10<br />
16<br />
160<br />
22,4<br />
315<br />
pd<br />
99<br />
98<br />
97<br />
96<br />
95<br />
94<br />
93<br />
92<br />
91<br />
90<br />
89<br />
113<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.34 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
11 200<br />
3,15<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,64<br />
12 500<br />
3,55<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,74<br />
14 000<br />
4,0<br />
6,3<br />
25<br />
9,0<br />
50<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/900/D*<br />
ROTATIONAL SPEED 950 RPM<br />
Tip speed u 2 = 44 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
16 000<br />
4,5<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,79<br />
18 000<br />
5,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
20 000<br />
5,6<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,84<br />
22 400<br />
6,3<br />
10<br />
63<br />
14<br />
125<br />
25 000<br />
7,1<br />
11,2<br />
80<br />
16<br />
160<br />
0,87<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
28 000<br />
8,0<br />
12,5<br />
100<br />
18<br />
200<br />
Moment of inertia I = 1.20 kg m 2<br />
Casing diameter d.i.L. = 894 mm<br />
Outlet cross section A 2 = 0.63 m 2<br />
15°<br />
0,43<br />
31 500<br />
9,0<br />
14<br />
125<br />
20<br />
250<br />
20°<br />
35 500<br />
10<br />
16<br />
160<br />
22,4<br />
315<br />
� = 0,78<br />
0,53<br />
40 000<br />
11,2<br />
18<br />
200<br />
25<br />
400<br />
0,73<br />
pd<br />
25°<br />
0,63<br />
25°<br />
45 000<br />
12,5<br />
20<br />
250<br />
28<br />
500<br />
0,68<br />
pd<br />
105<br />
104<br />
103<br />
102<br />
101<br />
100<br />
99<br />
98<br />
97<br />
96<br />
95<br />
114<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.43 m 2<br />
35°<br />
30°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
18 000<br />
5,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,66<br />
20 000<br />
5,6<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,76<br />
22 400<br />
6,3<br />
10<br />
63<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/900/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u 2 = 67 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0°<br />
25 000<br />
7,1<br />
11,2<br />
80<br />
16<br />
160<br />
10°<br />
0,81<br />
0°<br />
28 000<br />
8,0<br />
12,5<br />
100<br />
18<br />
200<br />
5°<br />
5°<br />
31 500<br />
9,0<br />
14<br />
125<br />
20<br />
250<br />
15°<br />
0,86<br />
10°<br />
35 500<br />
10<br />
16<br />
160<br />
22,4<br />
315<br />
10°<br />
0,89<br />
40 000<br />
11,2<br />
18<br />
200<br />
25<br />
400<br />
15°<br />
45 000<br />
12,5<br />
20<br />
250<br />
28<br />
500<br />
Moment of inertia I = 1.20 kg m 2<br />
Casing diameter d.i.L. = 894 mm<br />
Outlet cross section A 2 = 0.63 m 2<br />
15°<br />
0,47<br />
50 000<br />
14<br />
22,4<br />
315<br />
31,5<br />
630<br />
20°<br />
20°<br />
0,57<br />
56 000<br />
16<br />
25<br />
400<br />
35,5<br />
800<br />
� = 0,80<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
63 000<br />
18<br />
28<br />
500<br />
40<br />
1000<br />
25°<br />
71 000<br />
20<br />
31,5<br />
630<br />
45<br />
1250<br />
0,72<br />
pd<br />
111<br />
110<br />
109<br />
108<br />
107<br />
106<br />
105<br />
104<br />
103<br />
102<br />
101<br />
115<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0.43 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
with duct 2,5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,64<br />
12 500<br />
3,55<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
14 000<br />
4,0<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
0,74<br />
16 000<br />
4,5<br />
5,6<br />
20<br />
8,0<br />
40<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1000/D*<br />
ROTATIONAL SPEED 720 RPM<br />
Tip speed u 2 = 38 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,79<br />
18 000<br />
5,0<br />
6,3<br />
25<br />
9,0<br />
50<br />
20 000<br />
5,6<br />
7,1<br />
31,5<br />
10<br />
63<br />
22 400<br />
6,3<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,84<br />
25 000<br />
7,1<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,87<br />
0° 0° 5° 5° 10° 10° 15°<br />
0 5 10 15<br />
10°<br />
15°<br />
28 000<br />
8,0<br />
10<br />
63<br />
14<br />
125<br />
31 500<br />
9,0<br />
11,2<br />
80<br />
16<br />
160<br />
15°<br />
0,45<br />
Moment of inertia I = 2.05 kg m 2<br />
Casing diameter d.i.L. = 1003 mm<br />
Outlet cross section A 2 = 0.79 m 2<br />
20<br />
35 500<br />
10<br />
12,5<br />
100<br />
18<br />
200<br />
20°<br />
� = 0,78<br />
0,55<br />
40 000<br />
11,2<br />
14<br />
125<br />
20<br />
250<br />
0,75<br />
pd<br />
25°<br />
0,65<br />
45 000<br />
12,5<br />
16<br />
160<br />
22,4<br />
315<br />
25°<br />
50 000<br />
14<br />
18<br />
200<br />
25<br />
400<br />
0,70<br />
pd<br />
102<br />
101<br />
100<br />
99<br />
98<br />
97<br />
96<br />
95<br />
94<br />
93<br />
92<br />
116<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0,54 m 2<br />
30°<br />
35°<br />
Total acoustic power levelL w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
16 000<br />
4,5<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,66<br />
18 000<br />
5,0<br />
6,3<br />
25<br />
9,0<br />
50<br />
0,76<br />
20 000<br />
5,6<br />
7,1<br />
31,5<br />
10<br />
63<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1000/D*<br />
ROTATIONAL SPEED 950 RPM<br />
Tip speed u 2 = 50 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
22 400<br />
6,3<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,81<br />
25 000<br />
7,1<br />
9,0<br />
50<br />
12,5<br />
100<br />
28 000<br />
8,0<br />
10<br />
63<br />
14<br />
125<br />
0,86<br />
31 500<br />
9,0<br />
11,2<br />
80<br />
16<br />
160<br />
35 500<br />
10<br />
12,5<br />
100<br />
18<br />
200<br />
0,89<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
40 000<br />
11,2<br />
14<br />
125<br />
20<br />
250<br />
Moment of inertia I = 2.05 kg m 2<br />
Casing diameter d.i.L. = 1003 mm<br />
Outlet cross section A 2 = 0.79 m 2<br />
15°<br />
0,47<br />
45 000<br />
12,5<br />
16<br />
160<br />
22,4<br />
315<br />
20°<br />
50 000<br />
14<br />
18<br />
200<br />
25<br />
400<br />
� = 0,80<br />
0,57<br />
56 000<br />
16<br />
20<br />
250<br />
28<br />
500<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
25°<br />
63 000<br />
18<br />
22,4<br />
315<br />
31,5<br />
630<br />
0,72<br />
pd<br />
108<br />
107<br />
106<br />
105<br />
104<br />
103<br />
102<br />
101<br />
100<br />
99<br />
98<br />
117<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0,54 m 2<br />
35°<br />
30°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1800<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,66<br />
25 000<br />
7,1<br />
9,0<br />
50<br />
12,5<br />
100<br />
28 000<br />
8,0<br />
10<br />
63<br />
14<br />
125<br />
0,76<br />
31 500<br />
9,0<br />
11,2<br />
80<br />
16<br />
160<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1000/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u 2 = 76 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0°<br />
35 500<br />
10<br />
12,5<br />
100<br />
18<br />
200<br />
0,81<br />
0°<br />
10°<br />
40 000<br />
11,2<br />
14<br />
125<br />
20<br />
250<br />
5°<br />
5°<br />
45 000<br />
12,5<br />
16<br />
160<br />
22,4<br />
315<br />
0,86<br />
15°<br />
10°<br />
50 000<br />
14<br />
18<br />
200<br />
25<br />
400<br />
10°<br />
0,89<br />
56 000<br />
16<br />
20<br />
250<br />
28<br />
500<br />
15°<br />
63 000<br />
18<br />
22,4<br />
315<br />
31,5<br />
630<br />
Moment of inertia I = 2.05 kg m 2<br />
Casing diameter d.i.L. = 1003 mm<br />
Outlet cross section A 2 = 0.79 m 2<br />
15°<br />
0,47<br />
71000<br />
20<br />
25<br />
400<br />
35,5<br />
800<br />
20°<br />
20°<br />
� = 0,80<br />
0,57<br />
80 000<br />
22,4<br />
28<br />
500<br />
40<br />
1000<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
90 000<br />
25<br />
31,5<br />
630<br />
45<br />
1250<br />
25°<br />
100 000<br />
28<br />
35,5<br />
800<br />
50<br />
1600<br />
0,72<br />
pd<br />
115<br />
114<br />
113<br />
112<br />
111<br />
110<br />
109<br />
108<br />
107<br />
106<br />
105<br />
118<br />
35°<br />
Blade Schaufelwinkel<br />
pitch angle<br />
30°<br />
upon auf Anfrage request<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0.54 m 2<br />
35°<br />
30°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,65<br />
18 000<br />
5,0<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
20 000<br />
5,6<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,75<br />
22 400<br />
6,3<br />
6,3<br />
25<br />
9,0<br />
50<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1120/D*<br />
ROTATIONAL SPEED 720 RPM<br />
Tip speed u 2 = 42 m/s<br />
Temperature t = 20° C<br />
Density = 1,2 kg/m 3<br />
0,80<br />
25 000<br />
7,1<br />
7,1<br />
31,5<br />
10<br />
63<br />
28 000<br />
8,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
31 500<br />
9,0<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,85<br />
35 500<br />
10<br />
10<br />
63<br />
14<br />
125<br />
0,88<br />
0° 0° 5° 5° 10° 10° 15°<br />
10°<br />
15°<br />
40 000<br />
11,2<br />
11,2<br />
80<br />
16<br />
160<br />
45 000<br />
12,5<br />
12,5<br />
100<br />
18<br />
200<br />
15°<br />
0,46<br />
Moment of inertia I = 3.63 kg m 2<br />
Casing diameter d.i.L. = 1124 mm<br />
Outlet cross section A 2 = 1.0 m 2<br />
50 000<br />
14<br />
14<br />
125<br />
20<br />
250<br />
20°<br />
� = 0,79<br />
0,56<br />
56 000<br />
16<br />
16<br />
160<br />
22,4<br />
315<br />
0,76<br />
pd<br />
25°<br />
0,66<br />
63 000<br />
18<br />
18<br />
200<br />
25<br />
400<br />
25°<br />
0,71<br />
71 000<br />
20<br />
20<br />
250<br />
28<br />
500<br />
pd<br />
106<br />
105<br />
104<br />
103<br />
102<br />
101<br />
100<br />
99<br />
98<br />
97<br />
96<br />
119<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
20°<br />
25°<br />
A 1 = 0.68 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,66<br />
25 000<br />
7,1<br />
7,1<br />
31,5<br />
10<br />
63<br />
28 000<br />
8,0<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,76<br />
31 500<br />
9,0<br />
9,0<br />
50<br />
12,5<br />
100<br />
0°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1120/D*<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u 2 = 57 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,81<br />
35 500<br />
10<br />
10<br />
63<br />
14<br />
125<br />
10°<br />
0°<br />
5°<br />
40 000<br />
11,2<br />
11,2<br />
80<br />
16<br />
160<br />
5°<br />
0,86<br />
45 000<br />
12,5<br />
12,5<br />
100<br />
18<br />
200<br />
15°<br />
10°<br />
50 000<br />
14<br />
14<br />
125<br />
20<br />
250<br />
10°<br />
0,89<br />
56 000<br />
16<br />
16<br />
160<br />
22,4<br />
315<br />
15°<br />
63 000<br />
18<br />
18<br />
200<br />
25<br />
400<br />
15°<br />
0,47<br />
Moment of inertia I = 3.63 kg m 2<br />
Casing diameter d.i.L. = 1124 mm<br />
Outlet cross section A 2 = 1.0 m 2<br />
20°<br />
71000<br />
20<br />
20<br />
250<br />
28<br />
500<br />
20°<br />
� = 0,80<br />
0,57<br />
80 000<br />
22,4<br />
22,4<br />
315<br />
31,5<br />
630<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
25°<br />
90 000<br />
25<br />
25<br />
400<br />
35,5<br />
800<br />
0,72<br />
100 000<br />
28<br />
28<br />
500<br />
40<br />
1000<br />
pd<br />
111<br />
110<br />
109<br />
108<br />
107<br />
106<br />
105<br />
104<br />
103<br />
102<br />
101<br />
120<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0.68 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]
01.01<br />
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
2240<br />
2000<br />
1800<br />
1600<br />
1400<br />
1250<br />
1110<br />
1000<br />
900<br />
800<br />
710<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
35 500<br />
10<br />
10<br />
63<br />
14<br />
125<br />
0,66<br />
40 000<br />
11,2<br />
11,2<br />
80<br />
16<br />
160<br />
0,76<br />
45 000<br />
12,5<br />
12,5<br />
100<br />
18<br />
200<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1120/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u 2 = 82 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0°<br />
50 000<br />
14<br />
14<br />
125<br />
20<br />
250<br />
10°<br />
0,81<br />
0°<br />
56 000<br />
16<br />
16<br />
160<br />
22,4<br />
315<br />
5°<br />
5°<br />
63 000<br />
18<br />
18<br />
200<br />
25<br />
400<br />
15°<br />
0,86<br />
71 000<br />
20<br />
20<br />
250<br />
28<br />
500<br />
80 000<br />
22,4<br />
22,4<br />
315<br />
31,5<br />
630<br />
90 000<br />
25<br />
25<br />
400<br />
35,5<br />
800<br />
Moment of Inertia I = 3.63 kg m 2<br />
Casing Diameter d.i.L. = 1124 mm<br />
Outlet cross section A 2 = 1.0 m 2<br />
100 000<br />
28<br />
28<br />
500<br />
40<br />
1000<br />
112 000<br />
31,5<br />
31,5<br />
630<br />
45<br />
1250<br />
125 000<br />
35,5<br />
35,5<br />
800<br />
50<br />
1600<br />
140 000<br />
40<br />
40<br />
1000<br />
56<br />
2000<br />
119<br />
118<br />
117<br />
116<br />
115<br />
114<br />
113<br />
112<br />
111<br />
110<br />
109<br />
121<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
10°<br />
10°<br />
0,89<br />
15°<br />
15°<br />
0,47<br />
20°<br />
20°<br />
� = 0,80<br />
0,57<br />
20°<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
25°<br />
25°<br />
A 1 = 0.68 m 2<br />
0,72<br />
30°<br />
35°<br />
pd<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct Drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
25 000<br />
7,1<br />
5,6<br />
20<br />
8,0<br />
40<br />
0,66<br />
28 000<br />
8,0<br />
6,3<br />
25<br />
9,0<br />
50<br />
0,76<br />
31 500<br />
9,0<br />
7,1<br />
31,5<br />
10<br />
63<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1250/D*<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u 2 = 49 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0°<br />
35 500<br />
10<br />
8,0<br />
40<br />
11,2<br />
80<br />
10°<br />
0,81<br />
0°<br />
40 000<br />
11,2<br />
9,0<br />
50<br />
12,5<br />
100<br />
5°<br />
45 000<br />
12,5<br />
10<br />
63<br />
14<br />
125<br />
5°<br />
15°<br />
0,86<br />
10°<br />
50 000<br />
14<br />
11,2<br />
80<br />
16<br />
160<br />
10°<br />
56 000<br />
16<br />
12,5<br />
100<br />
18<br />
200<br />
0,89<br />
15°<br />
63 000<br />
18<br />
14<br />
125<br />
20<br />
250<br />
Moment of inertia I = 6.25 kg m 2<br />
Casing diameter d.i.L. = 1261 mm<br />
Outlet cross section A 2 = 1.25 m 2<br />
15°<br />
0,47<br />
71 000<br />
20<br />
16<br />
160<br />
22,4<br />
315<br />
20°<br />
20°<br />
0,57<br />
80 000<br />
22,4<br />
18<br />
200<br />
25<br />
400<br />
� = 0,80<br />
0,77<br />
pd<br />
25°<br />
90 000<br />
25<br />
20<br />
250<br />
28<br />
500<br />
0,67<br />
25°<br />
100 000<br />
28<br />
22,4<br />
315<br />
31,5<br />
630<br />
0,72<br />
pd<br />
108<br />
107<br />
106<br />
105<br />
104<br />
103<br />
102<br />
101<br />
100<br />
99<br />
98<br />
122<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 0.85 m 2<br />
35°<br />
30°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,66<br />
35 500<br />
10<br />
8,0<br />
40<br />
11,2<br />
80<br />
40 000<br />
11,2<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,76<br />
45 000<br />
12,5<br />
10<br />
63<br />
14<br />
125<br />
0°<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1250/D*<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u 2 = 64 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,81<br />
0°<br />
50 000<br />
14<br />
11,2<br />
80<br />
16<br />
160<br />
5°<br />
56 000<br />
16<br />
12,5<br />
100<br />
18<br />
200<br />
15°<br />
5°<br />
0,86<br />
63 000<br />
18<br />
14<br />
125<br />
20<br />
250<br />
10°<br />
10°<br />
71000<br />
20<br />
16<br />
160<br />
22,4<br />
315<br />
0,89<br />
15°<br />
80 000<br />
22,4<br />
18<br />
200<br />
25<br />
400<br />
90 000<br />
25<br />
20<br />
250<br />
28<br />
500<br />
15°<br />
0,47<br />
Moment of inertia I = 6.25 kg m 2<br />
Casing diameter d.i.L. = 1261 mm<br />
Outlet cross section A 2 = 1.25 m 2<br />
20°<br />
100 000<br />
28<br />
22,4<br />
315<br />
31,5<br />
630<br />
20°<br />
� = 0,80<br />
0,57<br />
112 000<br />
31,5<br />
25<br />
400<br />
35,5<br />
800<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
25°<br />
125 000<br />
35,5<br />
28<br />
500<br />
40<br />
1000<br />
0,72<br />
140 000<br />
40<br />
31,5<br />
630<br />
45<br />
1250<br />
pd<br />
114<br />
113<br />
112<br />
111<br />
110<br />
109<br />
108<br />
107<br />
106<br />
105<br />
104<br />
123<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.85 m 2<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
2800<br />
2500<br />
2240<br />
2000<br />
1800<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
·<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
50 000<br />
14<br />
11,2<br />
80<br />
16<br />
160<br />
0,66<br />
56 000<br />
16<br />
12,5<br />
100<br />
18<br />
200<br />
0,76<br />
63 000<br />
18<br />
14<br />
125<br />
20<br />
250<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1250/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u 2 = 95 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
71 000<br />
20<br />
16<br />
160<br />
22,4<br />
315<br />
0,81<br />
80 000<br />
22,4<br />
18<br />
200<br />
25<br />
400<br />
90 000<br />
25<br />
20<br />
250<br />
28<br />
500<br />
10° 15°<br />
0,86<br />
100 000<br />
28<br />
22,4<br />
315<br />
31,5<br />
630<br />
112 000<br />
31,5<br />
25<br />
400<br />
35,5<br />
800<br />
125 000<br />
35,5<br />
28<br />
500<br />
40<br />
1000<br />
Moment of inertia I = 6.25 kg m 2<br />
Casing diameter d.i.L. = 1261 mm<br />
Outlet cross section A 2 = 1.25 m 2<br />
140 000<br />
40<br />
31,5<br />
630<br />
45<br />
1250<br />
160 000<br />
45<br />
35,5<br />
800<br />
50<br />
1600<br />
180 000<br />
50<br />
40<br />
1000<br />
56<br />
2000<br />
A 1 = 1.07 m 2<br />
200 000<br />
56<br />
45<br />
1250<br />
63<br />
2500<br />
122<br />
121<br />
120<br />
119<br />
118<br />
117<br />
116<br />
115<br />
114<br />
113<br />
112<br />
124<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
0,89<br />
0° 0° 5° 5° 10° 10° 15°<br />
15°<br />
20°<br />
η = 0,80<br />
20°<br />
0,57<br />
20°<br />
25°<br />
0,77<br />
pd<br />
25°<br />
25°<br />
0,72<br />
0,67<br />
30°<br />
35°<br />
30°<br />
pd<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
35 500<br />
10<br />
6,3<br />
25<br />
9,0<br />
50<br />
0,66<br />
40 000<br />
11,2<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,76<br />
45 000<br />
12,5<br />
8,0<br />
40<br />
11,2<br />
80<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1400/D*<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u 2 = 54 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0°<br />
50 000<br />
14<br />
9,0<br />
50<br />
12,5<br />
100<br />
10°<br />
0,81<br />
0°<br />
56 000<br />
16<br />
10<br />
63<br />
14<br />
125<br />
5°<br />
63 000<br />
18<br />
11,2<br />
80<br />
16<br />
160<br />
5°<br />
15°<br />
0,86<br />
71 000<br />
20<br />
12,5<br />
100<br />
18<br />
200<br />
80 000<br />
22,4<br />
14<br />
125<br />
20<br />
250<br />
90 000<br />
25<br />
16<br />
160<br />
22,4<br />
315<br />
Moment of inertia I = 10.05 kg m 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A 2 = 1.57 m 2<br />
100 000<br />
28<br />
18<br />
200<br />
25<br />
400<br />
112 000<br />
31,5<br />
20<br />
250<br />
28<br />
500<br />
125 000<br />
35,5<br />
22,4<br />
315<br />
31,5<br />
630<br />
140 000<br />
40<br />
25<br />
400<br />
35,5<br />
800<br />
112<br />
111<br />
110<br />
109<br />
108<br />
107<br />
106<br />
105<br />
104<br />
103<br />
102<br />
125<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
10°<br />
10°<br />
0,89<br />
15°<br />
15°<br />
0,47<br />
20°<br />
20°<br />
� = 0,80<br />
0,57<br />
20°<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
25°<br />
25°<br />
A 1 = 1.07 m 2<br />
0,72<br />
35°<br />
30°<br />
pd<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,66<br />
50 000<br />
14<br />
9,0<br />
50<br />
12,5<br />
100<br />
56 000<br />
16<br />
10<br />
63<br />
14<br />
125<br />
0,76<br />
63 000<br />
18<br />
11,2<br />
80<br />
16<br />
160<br />
0°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1400/D*<br />
ROTATIONAL SPEED 980 RPM<br />
10°<br />
Tip speed u 2 = 72 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,81<br />
0°<br />
71000<br />
20<br />
12,5<br />
100<br />
18<br />
200<br />
5°<br />
80 000<br />
22,4<br />
14<br />
125<br />
20<br />
250<br />
5°<br />
90 000<br />
25<br />
16<br />
160<br />
22,4<br />
315<br />
15°<br />
0,86<br />
10°<br />
100 000<br />
28<br />
18<br />
200<br />
25<br />
400<br />
10°<br />
0,89<br />
112 000<br />
31,5<br />
20<br />
250<br />
28<br />
500<br />
15°<br />
125 000<br />
35,5<br />
22,4<br />
315<br />
31,5<br />
630<br />
15°<br />
0,47<br />
Moment of inertia I = 10.05 kg m 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A 2 = 1.57 m 2<br />
20°<br />
140 000<br />
40<br />
25<br />
400<br />
35,5<br />
800<br />
20°<br />
� = 0,80<br />
0,57<br />
160 000<br />
45<br />
28<br />
500<br />
40<br />
1000<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
25°<br />
180 000<br />
50<br />
31,5<br />
630<br />
45<br />
1250<br />
0,72<br />
200 000<br />
56<br />
35,5<br />
800<br />
50<br />
1600<br />
pd<br />
117<br />
116<br />
115<br />
114<br />
113<br />
112<br />
111<br />
110<br />
109<br />
108<br />
107<br />
126<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 1.07 m 2<br />
30°<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
50 000<br />
14<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,66<br />
56 000<br />
16<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,76<br />
63 000<br />
18<br />
9,0<br />
50<br />
12,5<br />
100<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1600/D*<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u 2 = 61 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0°<br />
71 000<br />
20<br />
10<br />
63<br />
14<br />
125<br />
10°<br />
0,81<br />
0°<br />
80 000<br />
22,4<br />
11,2<br />
80<br />
16<br />
160<br />
5°<br />
90 000<br />
25<br />
12,5<br />
100<br />
18<br />
200<br />
5°<br />
15°<br />
0,86<br />
10°<br />
100 000<br />
28<br />
14<br />
125<br />
20<br />
250<br />
10°<br />
112 000<br />
31,5<br />
16<br />
160<br />
22,4<br />
315<br />
0,89<br />
15°<br />
125 000<br />
35,5<br />
18<br />
200<br />
25<br />
400<br />
Moment of inertia I = 17.25 kg m 2<br />
Casing diameter d.i.L. = 1587 mm<br />
Outlet cross section A 2 = 1.98 m 2<br />
15°<br />
0,47<br />
140 000<br />
40<br />
20<br />
250<br />
28<br />
500<br />
20°<br />
20°<br />
160 000<br />
45<br />
22,4<br />
315<br />
31,5<br />
630<br />
� = 0,80<br />
0,57<br />
0,77<br />
pd<br />
25°<br />
180 000<br />
50<br />
25<br />
400<br />
35,5<br />
800<br />
0,67<br />
25°<br />
200 000<br />
56<br />
28<br />
500<br />
40<br />
1000<br />
0,72<br />
pd<br />
114<br />
113<br />
112<br />
111<br />
110<br />
109<br />
108<br />
107<br />
106<br />
105<br />
104<br />
127<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 1,31 m 2<br />
35°<br />
30°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
2000<br />
1800<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
0,66<br />
71000<br />
20<br />
10<br />
63<br />
14<br />
125<br />
80 000<br />
22,4<br />
11,2<br />
80<br />
16<br />
160<br />
0,76<br />
90 000<br />
25<br />
12,5<br />
100<br />
18<br />
200<br />
0°<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1600/D*<br />
ROTATIONAL SPEED 980 RPM<br />
Tip speed u 2 = 81 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0,81<br />
0°<br />
100 000<br />
28<br />
14<br />
125<br />
20<br />
250<br />
5°<br />
112 000<br />
31,5<br />
16<br />
160<br />
22,4<br />
315<br />
5°<br />
15°<br />
0,86<br />
125 000<br />
35,5<br />
18<br />
200<br />
25<br />
400<br />
10°<br />
10°<br />
140 000<br />
40<br />
20<br />
250<br />
28<br />
500<br />
0,89<br />
15°<br />
160 000<br />
45<br />
22,4<br />
315<br />
31,5<br />
630<br />
180 000<br />
50<br />
25<br />
400<br />
35,5<br />
800<br />
15°<br />
0,47<br />
Moment of inertia I = 17.25 kg m 2<br />
Casing diameter d.i.L. = 1587 mm<br />
Outlet cross section A 2 = 1.98 m 2<br />
20°<br />
200 000<br />
56<br />
28<br />
500<br />
40<br />
1000<br />
20°<br />
� = 0,80<br />
0,57<br />
224 000<br />
63<br />
31,5<br />
630<br />
45<br />
1250<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
25°<br />
250 000<br />
71<br />
35,5<br />
800<br />
50<br />
1600<br />
0,72<br />
280 000<br />
80<br />
40<br />
1000<br />
56<br />
2000<br />
pd<br />
120<br />
119<br />
118<br />
117<br />
116<br />
115<br />
114<br />
113<br />
112<br />
111<br />
110<br />
128<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 1.31 m 2<br />
35°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
71 000<br />
20<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,66<br />
80 000<br />
22,4<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,76<br />
90 000<br />
25<br />
10<br />
63<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/1800/D*<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u 2 = 68 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0°<br />
100 000<br />
28<br />
11,2<br />
80<br />
16<br />
160<br />
10°<br />
0,81<br />
0°<br />
112 000<br />
31,5<br />
12,5<br />
100<br />
18<br />
200<br />
5°<br />
125 000<br />
35,5<br />
14<br />
125<br />
20<br />
250<br />
5°<br />
15°<br />
0,86<br />
10°<br />
140 000<br />
40<br />
16<br />
160<br />
22,4<br />
315<br />
10°<br />
160 000<br />
45<br />
18<br />
200<br />
25<br />
400<br />
0,89<br />
15°<br />
180 000<br />
50<br />
20<br />
250<br />
28<br />
500<br />
Moment of inertia I = 28.75 kg m 2<br />
Casing diameter d.i.L. = 1780 mm<br />
Outlet cross section A 2 = 2.49 m 2<br />
15°<br />
0,47<br />
200 000<br />
56<br />
22,4<br />
315<br />
31,5<br />
630<br />
20°<br />
20°<br />
224 000<br />
63<br />
25<br />
400<br />
35,5<br />
800<br />
� = 0,80<br />
0,57<br />
0,77<br />
pd<br />
25°<br />
250 000<br />
71<br />
28<br />
500<br />
40<br />
1000<br />
0,67<br />
25°<br />
280 000<br />
80<br />
31,5<br />
630<br />
45<br />
1250<br />
0,72<br />
pd<br />
118<br />
117<br />
116<br />
115<br />
114<br />
113<br />
112<br />
111<br />
110<br />
109<br />
108<br />
129<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 1.7 m 2<br />
35°<br />
30°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
80 000<br />
22,4<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,66<br />
90 000<br />
25<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,76<br />
100 000<br />
28<br />
9,0<br />
50<br />
12,5<br />
100<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/2000/D*<br />
ROTATIONAL SPEED 580 RPM<br />
Tip speed u 2 = 60 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0°<br />
112 000<br />
31,5<br />
10<br />
63<br />
14<br />
125<br />
10°<br />
0,81<br />
0°<br />
125 000<br />
35,5<br />
11,2<br />
80<br />
16<br />
160<br />
5°<br />
5°<br />
140 000<br />
40<br />
12,5<br />
100<br />
18<br />
200<br />
15°<br />
0,86<br />
10°<br />
160 000<br />
45<br />
14<br />
125<br />
20<br />
250<br />
10°<br />
0,89<br />
180 000<br />
50<br />
16<br />
160<br />
22,4<br />
315<br />
15°<br />
200 000<br />
56<br />
18<br />
200<br />
25<br />
400<br />
Moment of inertia I = 43.75 kg m 2<br />
Casing diameter d.i.L. = 1997 mm<br />
Outlet cross section A 2 = 3.13 m 2<br />
15°<br />
0,47<br />
224 000<br />
63<br />
20<br />
250<br />
28<br />
500<br />
20°<br />
20°<br />
0,57<br />
250 000<br />
71<br />
22,4<br />
315<br />
31,5<br />
630<br />
� = 0,80<br />
0,77<br />
pd<br />
25°<br />
0,67<br />
280 000<br />
80<br />
25<br />
400<br />
35,5<br />
800<br />
25°<br />
315 000<br />
90<br />
28<br />
500<br />
40<br />
1000<br />
0,72<br />
pd<br />
117<br />
116<br />
115<br />
114<br />
113<br />
112<br />
111<br />
110<br />
109<br />
108<br />
107<br />
130<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 2.15 m 2<br />
35°<br />
30°<br />
Total acoustic power level L w [dB]
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
1800<br />
1600<br />
1400<br />
1250<br />
1120<br />
1000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
5°<br />
0°<br />
100 000<br />
28<br />
9,0<br />
50<br />
12,5<br />
100<br />
0,66<br />
112 000<br />
31,5<br />
10<br />
63<br />
14<br />
125<br />
0,76<br />
125 000<br />
35,5<br />
11,2<br />
80<br />
16<br />
160<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/2000/D*<br />
ROTATIONAL SPEED 740 RPM<br />
Tip speed u 2 = 77 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
0°<br />
140 000<br />
40<br />
12,5<br />
100<br />
18<br />
200<br />
0,81<br />
10°<br />
0°<br />
160 000<br />
45<br />
14<br />
125<br />
20<br />
250<br />
5°<br />
180 000<br />
50<br />
16<br />
160<br />
22,4<br />
315<br />
5°<br />
15°<br />
0,86<br />
10°<br />
200 000<br />
56<br />
18<br />
200<br />
25<br />
400<br />
10°<br />
224 000<br />
63<br />
20<br />
250<br />
28<br />
500<br />
0,89<br />
15°<br />
250 000<br />
71<br />
22,4<br />
315<br />
31,5<br />
630<br />
Moment of inertia I = 43.75 kg m 2<br />
Casing diameter d.i.L. = 1997 mm<br />
Outlet cross section A 2 = 3.13 m 2<br />
15°<br />
0,47<br />
280 000<br />
80<br />
25<br />
400<br />
35,5<br />
800<br />
20°<br />
20°<br />
315 000<br />
90<br />
28<br />
500<br />
40<br />
1000<br />
� = 0,80<br />
0,57<br />
0,77<br />
pd<br />
25°<br />
355 000<br />
100<br />
31,5<br />
630<br />
45<br />
1250<br />
0,67<br />
25°<br />
400 000<br />
112<br />
35,5<br />
800<br />
50<br />
1600<br />
0,72<br />
pd<br />
122<br />
121<br />
120<br />
119<br />
118<br />
117<br />
116<br />
115<br />
114<br />
113<br />
112<br />
131<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
A 1 = 2.15 m 2<br />
35°<br />
30°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive
Item<br />
Nr.<br />
Qty. Description<br />
or<br />
or<br />
or<br />
or<br />
– 132 –<br />
<strong>Axial</strong> Flow Fan – AXN Series, Type M-D<br />
Airflow direction: motor in outlet<br />
Direct-drive type<br />
consisting of<br />
Casing of welded sheet steel construction<br />
with drilled flanges according to DIN 24 154, Series 3.<br />
Outlet guide vanes for boosting outlet pressure and<br />
achieving an essentially swirl-free outlet flow<br />
Surface protection:<br />
• Polyester powder coating<br />
Colour: RAL 7030<br />
• as of nominal size 1120: with full paint finish<br />
Colour: RAL 7030<br />
Aluminium impeller, blade pitch steplessly adjustable when<br />
fan is at rest, directly mounted on motor shaft end.<br />
Outlet-side installation:<br />
• Duct connection<br />
• Direct outlet without diffuser<br />
• Outlet into diffuser (optional)<br />
Specifications<br />
Volume flow m3/h Dynamic inlet pressure Pa<br />
Dynamic outlet pressure Pa<br />
Total pressure increase of fan Pa<br />
Pressure loss of accessories Pa<br />
External pressure loss Pa<br />
Temperature °C<br />
Density kg/m3 Fan rotational speed rpm<br />
Blade pitch angle °<br />
Total acoustic power level L w<br />
dB<br />
Efficiency %<br />
Power required at shaft kW<br />
Three-phase a.c. motor<br />
• single speed<br />
• Dahlander pole-changing type<br />
• pole-changing type with seperate windings<br />
Motor speed rpm<br />
Motor output kW<br />
Current consumption A<br />
Voltage Volt<br />
Frequency Hz<br />
Protection class IP<br />
Type B<br />
Size<br />
Weight kg<br />
Manufacturer: <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Type: AXN 12/56/ ..........M-D<br />
Carryover<br />
Unit price<br />
2<br />
Total<br />
2
Item<br />
Nr.<br />
Qty. Description<br />
Options:<br />
• Electric motor<br />
– 133 –<br />
• Exterior terminal box wired to electric motor<br />
• Assembly cost for supplied motor<br />
• Galvanized fan<br />
• Fan with special coating<br />
• Extension casing without inspection hatch<br />
• Extension casing with inspection hatch<br />
• Inspection hatch in standard duct<br />
(nominal size 1120 and over)<br />
• Bellmouth inlet with flange<br />
• Wire guard on bellmouth or motor side<br />
• Wire guard on extension casing<br />
• Flexible connector, inlet side *<br />
• Flexible connector, outlet side *<br />
• Matching flange *<br />
• Angular wall ring with brackets *<br />
• Set of mounting feet (2 pcs.) *<br />
• Set of rubber antivibration mounts *<br />
• Set of spring-type antivibration mounts *<br />
• Brackets for vertical fan installation<br />
Carryover<br />
• Spark-proof equipment (hazardous-duty models only)<br />
• Diffuser with interior core *<br />
• Round silencer, TSR type *<br />
• Insulating casing<br />
Note: Please see our Installation, Operating<br />
and Maintenance Instructions<br />
available upon request.<br />
* Loosely supplied<br />
Unit price<br />
2<br />
Total<br />
2<br />
AXN-Direct drive
Item<br />
Nr.<br />
Qty. Description<br />
or<br />
or<br />
or<br />
or<br />
– 134 –<br />
<strong>Axial</strong> Flow Fan – AXN Series, Type M-A<br />
swing-out design,<br />
direct-drive type<br />
consisting of<br />
Casing of heavy-duty welded sheet steel construction<br />
with drilled flanges according to DIN 24 154, Series 4.<br />
Outlet guide vanes for boosting outlet pressure and<br />
achieving an essentially swirl-free outlet flow<br />
Surface protection:<br />
• Full paint finish, colour: RAL 7030<br />
Aluminium impeller, blade pitch steplessly adjustable when<br />
fan is at rest, directly mounted on motor shaft end.<br />
Guide vane installation, motor mounting (with motor)<br />
and impeller can be jointly swivelled out<br />
for maintenance and cleaning.<br />
Outlet-side installation:<br />
• Duct connection<br />
• Direct outlet without diffuser<br />
• Outlet into diffuser (option)<br />
Specifications<br />
Volume flow m3/h Dynamic inlet pressure Pa<br />
Dynamic outlet pressure Pa<br />
Total pressure increase of fan Pa<br />
Pressure loss of accessories Pa<br />
External pressure loss Pa<br />
Temperature °C<br />
Density kg/m3 Fan rotational speed rpm<br />
Blade pitch angle °<br />
Total acoustic power level L w<br />
dB<br />
Efficiency %<br />
Power required at shaft kW<br />
Three-phase a.c. motor<br />
• single speed<br />
• Dahlander pole-changing type<br />
• pole-changing type with seperate windings<br />
Motor speed rpm<br />
Motor output kW<br />
Current consumption A<br />
Voltage Volt<br />
Frequency Hz<br />
Protection class IP<br />
Type B<br />
Size<br />
Weight kg<br />
Manufacturer: <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Type: AXN 12/56/ ..........M-A<br />
Carryover<br />
Unit price<br />
2<br />
Total<br />
2
Item<br />
Nr.<br />
Qty. Description<br />
Options:<br />
• Electric motor<br />
– 135 –<br />
• Exterior terminal box wired to electric motor<br />
• Assembly cost for supplied motor<br />
• Galvanized fan<br />
• Fan with special coating<br />
• Bellmouth inlet with flange<br />
• Wire guard on bellmouth or motor side<br />
• Wire guard on extension casing<br />
• Flexible connector, inlet side *<br />
• Flexible connector, outlet side *<br />
• Matching flange *<br />
• Angular wall ring with brackets *<br />
• Set of mounting feet (2 pcs.) *<br />
• Set of rubber antivibration mounts *<br />
• Set of spring-type antivibration mounts *<br />
• Brackets for vertical fan installation<br />
Carryover<br />
• Spark-proof equipment (hazardous-duty models only)<br />
• Diffuser with interior core *<br />
• Round silencer, TSR type *<br />
Note: Please see our Installation, Operating<br />
and Maintenance Instructions<br />
available upon request.<br />
* Loosely supplied<br />
Unit price<br />
2<br />
Total<br />
2<br />
AXN-Direct drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
View „A“<br />
View "B"<br />
(shown without louvre-type damper)<br />
Please refer to characteristic<br />
curves on pages 095 to 112.<br />
Size<br />
WALL-MOUNTING AXIAL FANS<br />
WAXN SERIES<br />
200 / 300 °C – 120 MIN<br />
Direction of flow<br />
900<br />
Wall opening<br />
Pressure loss across shutoff damper (overpressure louvre)<br />
Dimensions in mm<br />
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).<br />
136<br />
Flow velocity*c<br />
Pressure losses of fan and shutoff damper sum up to the total pressure<br />
increase needed for the sizing of complete fan units (assuming free<br />
inlet / free outlet conditions).<br />
*For flow velocities please refer to the characteristic curves „free outlet“<br />
installation (red curves and numbers)<br />
Weight<br />
approx. [kg]<br />
(without<br />
motor)
Item<br />
Nr.<br />
Qty. Description<br />
or<br />
or<br />
– 137 –<br />
Wall-mounting <strong>Axial</strong> Flow Fan WAXN 12/56<br />
Type M-D<br />
Airflow direction: motor in outlet, direct drive.<br />
Wall-mounting type<br />
Consisting of:<br />
Duct casing of welded sheet steel construction, with drilled<br />
flanges according to DIN 24154 - Series 3; guide vanes for<br />
pressure boosting and to ensure an essentially swirl-free<br />
outlet flow; 3-phase a.c. standard motor arranged in the<br />
flow, with terminal box fitted on the casing.<br />
Surface protection:<br />
• Polyester powder coating, colour: RAL 7030<br />
Louvre damper slats: made of aluminium<br />
Louvre damper frame and wire guard: galvanized.<br />
• Impeller made of cast aluminium, blades steplessly<br />
adjustable on the stationary fan, directly mounted on<br />
motor shaft<br />
• Bellmouth with wire guard<br />
• Wall-mounting plate (inside)<br />
• Outlet box (outside)<br />
• Louvre damper (outside)<br />
Specifications<br />
Volume flow m3/h Dynamic inlet pressure Pa<br />
Dynamic outlet pressure Pa<br />
Total pressure increase of fan Pa<br />
Pressure loss of accessories Pa<br />
External pressure loss Pa<br />
Temperature °C<br />
Density kg/m3 Fan rotational speed rpm<br />
Blade pitch angle °<br />
Total acoustic power level L w<br />
dB<br />
Efficiency %<br />
Power required at shaft kW<br />
Three-phase motor<br />
single-speed<br />
with Dahlander pole-changing type<br />
pole-changing type with separate windings<br />
Motor speed rpm<br />
Motor output kW<br />
Nominal motor current A<br />
Voltage V<br />
Frequency Hz<br />
Protection class IP<br />
Style B<br />
Size<br />
Weight of fan with accessories kg<br />
Manufacturer: <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Type: WAXN 12/56<br />
Accessory equipment needed in connection with use of inlet<br />
duct<br />
• Flexible connector (in this case please deduct price of<br />
bellmouth and inlet wire guard from fan price)<br />
Note: Please observe our Installation, Operating and Maintenance<br />
Instructions (available upon request).<br />
Unit price<br />
2<br />
Total<br />
2<br />
WAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 300<br />
2 100<br />
1 900<br />
1 700<br />
1 520<br />
1 340<br />
1 200<br />
1 060<br />
940<br />
830<br />
750<br />
680<br />
600<br />
530<br />
470<br />
420<br />
370<br />
330<br />
290<br />
260<br />
230<br />
210<br />
180<br />
160<br />
140<br />
130<br />
120<br />
100<br />
90<br />
80<br />
70<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 0.024 kgm 2<br />
Casing diameter d.i.L. = 401 mm<br />
Outlet cross section A 2 = 0.126 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
4 500<br />
1,25<br />
10<br />
63<br />
5 000<br />
1,4<br />
11,2<br />
80<br />
5 600<br />
1,6<br />
12,5<br />
100<br />
6 300<br />
1,8<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/400/R1<br />
7 100<br />
2,0<br />
16<br />
160<br />
8 000<br />
2,24<br />
18<br />
200<br />
9 000<br />
2,5<br />
20<br />
250<br />
10 000<br />
2,8<br />
22,4<br />
315<br />
Type R1<br />
max. 7.5 kW<br />
11 200<br />
3,15<br />
12 500<br />
3,55<br />
Type R2<br />
not available<br />
14 000<br />
4,0<br />
16 000<br />
4,5<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
6,8<br />
4,8<br />
3,4<br />
2,5<br />
1,8<br />
1,3<br />
0,9<br />
0,7<br />
0,5<br />
0,4<br />
Fan speed n [rpm]<br />
4 000<br />
3 580<br />
3 200<br />
2 870<br />
2 575<br />
2 310<br />
2 080<br />
1 875<br />
1 700<br />
1 530<br />
1 400<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
75<br />
67<br />
60<br />
54<br />
49<br />
44<br />
39<br />
36<br />
32<br />
29<br />
139<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,75<br />
25<br />
400<br />
� = 0,77<br />
0,74<br />
28<br />
500<br />
0,65<br />
0,58<br />
31,5<br />
630<br />
35,5<br />
800<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
90<br />
88<br />
86<br />
84<br />
82<br />
Belt drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 300<br />
2 100<br />
1 900<br />
1 700<br />
1 520<br />
1 340<br />
1 200<br />
1 060<br />
940<br />
830<br />
750<br />
680<br />
600<br />
530<br />
470<br />
420<br />
370<br />
330<br />
290<br />
260<br />
230<br />
210<br />
180<br />
160<br />
140<br />
130<br />
120<br />
100<br />
90<br />
80<br />
70<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 0.041 kgm 2<br />
Casing diameter d.i.L. = 450 mm<br />
Outlet cross section A 2 = 0.159 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
5 600<br />
1,6<br />
10<br />
63<br />
6 300<br />
1,8<br />
11,2<br />
80<br />
7 100<br />
2,0<br />
12,5<br />
100<br />
8 000<br />
2,24<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/450/R1<br />
Power limit<br />
Type R1 (7,5 kW)<br />
9 000<br />
2,5<br />
16<br />
160<br />
10 000<br />
2,8<br />
18<br />
200<br />
11 200<br />
3,15<br />
20<br />
250<br />
12 500<br />
3,55<br />
22,4<br />
315<br />
Type R1<br />
max. 7.5 kW<br />
14 000<br />
4,0<br />
25<br />
16 000<br />
4,5<br />
28<br />
Type R2<br />
not available<br />
18 000<br />
5,0<br />
31,5<br />
20 000<br />
5,6<br />
35,5<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
8,2<br />
6,0<br />
4,2<br />
3,0<br />
2,2<br />
1,6<br />
1,2<br />
0,85<br />
0,6<br />
0,45<br />
Fan speed n [rpm]<br />
3 550<br />
3 175<br />
2 840<br />
2 540<br />
2 275<br />
2 040<br />
1 835<br />
1 650<br />
1 485<br />
1 340<br />
1 215<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
75<br />
67<br />
60<br />
54<br />
49<br />
44<br />
39<br />
36<br />
32<br />
29<br />
140<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Fans with operating point in grid area upon request * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,76<br />
400<br />
� = 0,78<br />
0,75<br />
500<br />
0,66<br />
0,59<br />
630<br />
800<br />
102<br />
100<br />
98<br />
96<br />
94<br />
92<br />
90<br />
88<br />
86<br />
84<br />
82
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 300<br />
2 100<br />
1 900<br />
1 700<br />
1 520<br />
1 340<br />
1 200<br />
1 060<br />
940<br />
830<br />
750<br />
680<br />
600<br />
530<br />
470<br />
420<br />
370<br />
330<br />
290<br />
260<br />
230<br />
210<br />
180<br />
160<br />
140<br />
130<br />
120<br />
100<br />
90<br />
80<br />
70<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 0.073 kgm 2<br />
Casing diameter d.i.L. = 504 mm<br />
Outlet cross section A 2 = 0.2 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
7 100<br />
2,0<br />
10<br />
63<br />
8 000<br />
2,24<br />
11,2<br />
80<br />
9 000<br />
2,5<br />
12,5<br />
100<br />
10 000<br />
2,8<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/500/R1<br />
11 200<br />
3,15<br />
16<br />
160<br />
12 500<br />
3,55<br />
18<br />
200<br />
14 000<br />
4,0<br />
20<br />
250<br />
16 000<br />
4,5<br />
22,4<br />
315<br />
Type R1<br />
max. 11 kW<br />
18 000<br />
5,0<br />
20 000<br />
5,6<br />
Type R2<br />
not available<br />
22 400<br />
6,3<br />
25 000<br />
7,1<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
10.2<br />
7.4<br />
5.2<br />
3.7<br />
2.6<br />
1.9<br />
1.4<br />
1.0<br />
0.8<br />
0.6<br />
Fan speed n [rpm]<br />
3 150<br />
2 815<br />
2 515<br />
2 250<br />
2 015<br />
1 805<br />
1 620<br />
1 450<br />
1 310<br />
1 180<br />
1 065<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
75<br />
67<br />
60<br />
54<br />
49<br />
44<br />
39<br />
36<br />
32<br />
29<br />
141<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,77<br />
25<br />
400<br />
� = 0,79<br />
0,76<br />
28<br />
500<br />
0,62<br />
0,60<br />
31,5<br />
630<br />
35,5<br />
800<br />
104<br />
102<br />
100<br />
98<br />
96<br />
93<br />
91<br />
89<br />
86<br />
85<br />
83<br />
Belt drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 0.12 kgm 2<br />
Casing diameter d.i.L. = 565 mm<br />
Outlet cross section A 2 = 0.25 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
9 000<br />
2,5<br />
10<br />
63<br />
10 000<br />
2,8<br />
11,2<br />
80<br />
11 200<br />
3,15<br />
12,5<br />
100<br />
12 500<br />
3,55<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/560/R1<br />
Power limit<br />
Type R1 (11 kW)<br />
14 000<br />
4,0<br />
16<br />
160<br />
16 000<br />
4,5<br />
18<br />
200<br />
18 000<br />
5,0<br />
20<br />
250<br />
20 000<br />
5,6<br />
22,4<br />
315<br />
Type R1<br />
max. 11 kW<br />
22 400<br />
6,3<br />
25<br />
25 000<br />
7,1<br />
28<br />
Type R2<br />
not available<br />
28 000<br />
8,0<br />
31,5<br />
31 500<br />
9,0<br />
35,5<br />
Approx. shaft power input<br />
requirement [kW]<br />
12.5<br />
9.0<br />
6.3<br />
4.6<br />
3.15<br />
2.4<br />
1.6<br />
1.25<br />
0.85<br />
0.65<br />
Fan speed n [rpm]<br />
2 800<br />
2 500<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
142<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Luftrichtung D (über Motor drückend) – auf Normzahlen gerundete Werte<br />
0,77<br />
400<br />
� = 0,79<br />
0,76<br />
500<br />
0,67<br />
0,60<br />
630<br />
800<br />
105<br />
102<br />
100<br />
98<br />
96<br />
93<br />
91<br />
89<br />
86<br />
85<br />
83
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 0.223 kgm 2<br />
Casing diameter d.i.L. = 634 mm<br />
Outlet cross section A 2 = 0.31 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
11 200<br />
3,15<br />
10<br />
63<br />
12 500<br />
3,55<br />
11,2<br />
80<br />
14 000<br />
4,0<br />
12,5<br />
100<br />
16 000<br />
4,5<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/630/R1<br />
Power limit Type R1 (15 kW) 0,77<br />
18 000<br />
5,0<br />
16<br />
160<br />
20 000<br />
5,6<br />
18<br />
200<br />
22 400<br />
6,3<br />
20<br />
250<br />
25 000<br />
7,1<br />
22,4<br />
315<br />
Type R1<br />
max. 15 kW<br />
28 000<br />
8,0<br />
25<br />
31 500<br />
9,0<br />
28<br />
Type R2<br />
not available<br />
35 500<br />
10<br />
31,5<br />
40 000<br />
11,2<br />
35,5<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
16<br />
11.2<br />
8.0<br />
5.6<br />
4.0<br />
3.0<br />
2.24<br />
1.6<br />
1.12<br />
0.8<br />
Fan speed n [rpm]<br />
2 500<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
143<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Fans with operating point in grid area upon request * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
400<br />
� = 0,79<br />
0,76<br />
500<br />
0,67<br />
0,60<br />
630<br />
800<br />
105<br />
103<br />
101<br />
98<br />
96<br />
94<br />
92<br />
89<br />
87<br />
85<br />
83<br />
Belt drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades<br />
Moment of inertia I = 0.40 kgm 2<br />
Casing diameter d.i.L. = 711 mm<br />
Outlet cross section A 2 = 0.4 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
14 000<br />
4,0<br />
10<br />
63<br />
16 000<br />
4,5<br />
11,2<br />
80<br />
Power limit Type R1 (15 kW)<br />
18 000<br />
5,0<br />
12,5<br />
100<br />
20 000<br />
5,6<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/710/R1-R2<br />
22 400<br />
6,3<br />
16<br />
160<br />
25 000<br />
7,1<br />
18<br />
200<br />
28 000<br />
8,0<br />
20<br />
250<br />
31 500<br />
9,0<br />
22,4<br />
315<br />
Type R1<br />
max. 15 kW<br />
35 500<br />
10<br />
25<br />
40 000<br />
11,2<br />
28<br />
Type R2<br />
max. 22 kW<br />
45 000<br />
12,5<br />
31,5<br />
50 000<br />
14<br />
35,5<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
22.4<br />
15<br />
11.2<br />
7.5<br />
5.6<br />
3.8<br />
2.8<br />
1.9<br />
1.4<br />
1.0<br />
Fan speed n [rpm]<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
75<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
144<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,77<br />
400<br />
� = 0,79<br />
0,75<br />
500<br />
0,66<br />
0,61<br />
630<br />
0,52<br />
800<br />
106<br />
104<br />
102<br />
99<br />
97<br />
95<br />
93<br />
90<br />
88<br />
86<br />
84
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades<br />
Moment of inertia I = 0.69 kgm 2<br />
Casing diameter d.i.L. = 797 mm<br />
Outlet cross section A 2 = 0.5 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
18 000<br />
5,0<br />
10<br />
63<br />
20 000<br />
5,6<br />
11,2<br />
80<br />
22 400<br />
6,3<br />
12,5<br />
100<br />
Power limit<br />
Type R1 (15 kW)<br />
25 000<br />
7,1<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/800/R1-R2<br />
28 000<br />
8,0<br />
16<br />
160<br />
31 500<br />
9,0<br />
18<br />
200<br />
35 500<br />
10<br />
20<br />
250<br />
40 000<br />
11,2<br />
22,4<br />
315<br />
Type R1<br />
max. 15 kW<br />
45 000<br />
12,5<br />
25<br />
50 000<br />
14<br />
28<br />
Type R2<br />
max. 30 kW<br />
56 000<br />
16<br />
31,5<br />
63 000<br />
18<br />
35,5<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
28<br />
19<br />
14<br />
9.5<br />
7.0<br />
4.5<br />
3.6<br />
2.5<br />
1.8<br />
1.25<br />
Fan speed n [rpm]<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
75<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
145<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,77<br />
400<br />
� = 0,79<br />
0,75<br />
500<br />
0,66<br />
0,61<br />
630<br />
0,52<br />
800<br />
107<br />
105<br />
103<br />
100<br />
98<br />
96<br />
94<br />
92<br />
89<br />
87<br />
85<br />
Belt drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 1.20 kgm 2<br />
Casing diameter d.i.L. = 894 mm<br />
Outlet cross section A 2 = 0.63 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
22 400<br />
6,3<br />
10<br />
63<br />
25 000<br />
7,1<br />
11,2<br />
80<br />
Power limit<br />
Type R1 (15 kW)<br />
28 000<br />
8,0<br />
12,5<br />
100<br />
31 500<br />
9,0<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/900/R1-R2<br />
35 500<br />
10<br />
16<br />
160<br />
40 000<br />
11,2<br />
18<br />
200<br />
45 000<br />
12,5<br />
20<br />
250<br />
50 000<br />
14<br />
22,4<br />
315<br />
Type R1<br />
max. 15 kW<br />
56 000<br />
16<br />
25<br />
63 000<br />
18<br />
28<br />
Type R2<br />
max. 37 kW<br />
71 000<br />
20<br />
31,5<br />
80 000<br />
22,4<br />
35,5<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
33<br />
24<br />
17<br />
12<br />
8.5<br />
6.0<br />
4.5<br />
3.0<br />
2.2<br />
1.6<br />
Fan speed n [rpm]<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
75<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
146<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,79<br />
400<br />
� = 0,81<br />
0,76<br />
500<br />
0,67<br />
630<br />
0,62<br />
0,53<br />
800<br />
109<br />
107<br />
104<br />
102<br />
100<br />
98<br />
95<br />
93<br />
91<br />
89<br />
87
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 2.05 kgm 2<br />
Casing diameter d.i.L. = 1003 mm<br />
Outlet cross section A 2 = 0.79 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
28 000<br />
8,0<br />
10<br />
63<br />
31 500<br />
9,0<br />
11,2<br />
80<br />
Power limit<br />
Type R1 (22 kW)<br />
35 500<br />
10<br />
12,5<br />
100<br />
40 000<br />
11,2<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/1000/R1-R2<br />
45 000<br />
12,5<br />
16<br />
160<br />
50 000<br />
14<br />
18<br />
200<br />
56 000<br />
16<br />
20<br />
250<br />
63 000<br />
18<br />
22,4<br />
315<br />
Type R1<br />
max. 22 kW<br />
Type R2<br />
max. 45 kW<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
Fan speed n [rpm]<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
147<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,80<br />
71 000<br />
20<br />
25<br />
400<br />
� = 0,81<br />
� = 0,81<br />
0,76<br />
80 000<br />
22,4<br />
28<br />
500<br />
0,67<br />
0,62<br />
90 000<br />
25<br />
31,5<br />
630<br />
0,53<br />
100 000<br />
28<br />
35,5<br />
800<br />
43<br />
30<br />
21,5<br />
15<br />
11<br />
8,0<br />
5,5<br />
4,0<br />
2,8<br />
2,1<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
110<br />
107<br />
105<br />
103<br />
101<br />
98<br />
96<br />
94<br />
92<br />
90<br />
88<br />
Belt drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 3.63 kgm 2<br />
Casing diameter d.i.L. = 1124 mm<br />
Outlet cross section A 2 = 1.0 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
35 500<br />
10<br />
10<br />
63<br />
40 000<br />
11,2<br />
11,2<br />
80<br />
45 000<br />
12,5<br />
12,5<br />
100<br />
Power limit<br />
Type R1 (45 kW)<br />
50 000<br />
14<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/1120/R1-R2<br />
56 000<br />
16<br />
16<br />
160<br />
63 000<br />
18<br />
18<br />
200<br />
71 000<br />
20<br />
20<br />
250<br />
80 000<br />
22,4<br />
22,4<br />
315<br />
Type R1<br />
max. 45 kW<br />
Type R2<br />
max. 55 kW<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
Fan speed n [rpm]<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
148<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,80<br />
90 000<br />
25<br />
25<br />
400<br />
� = 0,81<br />
� = 0,81<br />
0,76<br />
100 000<br />
28<br />
28<br />
500<br />
0,67<br />
0,62<br />
112 000<br />
31,5<br />
31,5<br />
630<br />
0,53<br />
125 000<br />
35,5<br />
35,5<br />
800<br />
51<br />
36<br />
26<br />
18<br />
13<br />
9,5<br />
6,5<br />
4,8<br />
3,5<br />
2,5<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
111<br />
109<br />
107<br />
104<br />
102<br />
100<br />
98<br />
95<br />
93<br />
91<br />
89
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades:12<br />
Moment of inertia = 6.25 kgm 2<br />
Casing diameter = 1261 mm<br />
Outlet cross section A 2 = 1.25 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
45 000<br />
12,5<br />
10<br />
63<br />
50 000<br />
14<br />
11,2<br />
80<br />
56 000<br />
16<br />
12,5<br />
100<br />
63 000<br />
18<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/1250/R1-R2<br />
Power limit<br />
Type R1 (45 kW)<br />
71 000<br />
20<br />
16<br />
160<br />
80 000<br />
22,4<br />
18<br />
200<br />
90 000<br />
25<br />
20<br />
250<br />
100 000<br />
28<br />
22,4<br />
315<br />
Type R1<br />
max. 45 kW<br />
112 000<br />
31,5<br />
25<br />
125 000<br />
35,5<br />
28<br />
Type R2<br />
max. 75 kW<br />
140 000<br />
40<br />
31,5<br />
160 000<br />
45<br />
35,5<br />
Approx shaft power input<br />
requirement Pw [kW]<br />
63<br />
45<br />
34<br />
24<br />
17<br />
12<br />
8.5<br />
6.0<br />
4.2<br />
3.0<br />
Fan speed n [rpm]<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
355<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
149<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,80<br />
400<br />
� = 0,81<br />
0,76<br />
500<br />
0,68<br />
0,63<br />
630<br />
0,54<br />
800<br />
112<br />
109<br />
107<br />
105<br />
103<br />
100<br />
98<br />
96<br />
94<br />
91<br />
89<br />
Belt drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 10.05 kgm 2<br />
Casing diameter d.i.L. = 1415 mm<br />
Outlet cross section A 2 = 1.57 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
56 000<br />
16<br />
10<br />
63<br />
63 000<br />
18<br />
11,2<br />
80<br />
71 000<br />
20<br />
12,5<br />
100<br />
80 000<br />
22,4<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/1400/R2<br />
90 000<br />
25<br />
16<br />
160<br />
100 000<br />
28<br />
18<br />
200<br />
112 000<br />
31,5<br />
20<br />
250<br />
125 000<br />
35,5<br />
22,4<br />
315<br />
Type R1<br />
not available<br />
140 000<br />
40<br />
160 000<br />
45<br />
Type R2<br />
max. 90 kW<br />
180 000<br />
50<br />
200 000<br />
56<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
82<br />
58<br />
41<br />
29<br />
21<br />
15<br />
11<br />
7.5<br />
5.5<br />
3.8<br />
Fan speed n [rpm]<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
150<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,81<br />
25<br />
400<br />
� = 0,81<br />
0,77<br />
28<br />
500<br />
0,69<br />
0,64<br />
31,5<br />
630<br />
0,55<br />
35,5<br />
800<br />
113<br />
111<br />
109<br />
106<br />
104<br />
102<br />
100<br />
98<br />
95<br />
93<br />
91
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 17.25 kgm 2<br />
Casing diameter d.i.L. = 1587 mm<br />
Outlet cross section A 2 = 1.98 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
71 000<br />
20<br />
10<br />
63<br />
80 000<br />
22,4<br />
11,2<br />
80<br />
90 000<br />
25<br />
12,5<br />
100<br />
100 000<br />
28<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/1600/R2<br />
112 000<br />
31,5<br />
16<br />
160<br />
125 000<br />
35,5<br />
18<br />
200<br />
140 000<br />
40<br />
20<br />
250<br />
160 000<br />
45<br />
22,4<br />
315<br />
Type R1<br />
not available<br />
180 000<br />
50<br />
200 000<br />
56<br />
Type R2<br />
max. 110 kW<br />
224 000<br />
63<br />
250 000<br />
71<br />
Approx shaft power input<br />
requirement Pw [kW]<br />
104<br />
74<br />
52<br />
37<br />
26<br />
18.5<br />
13<br />
9.5<br />
7.0<br />
5.0<br />
Fan speed n [rpm]<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
151<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Ventilatoren mit Betriebspunkt im gerasterten Feld auf Anfrage * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,81<br />
25<br />
400<br />
� = 0,81<br />
0,77<br />
28<br />
500<br />
0,69<br />
0,64<br />
31,5<br />
630<br />
0,55<br />
35,5<br />
800<br />
114<br />
112<br />
110<br />
108<br />
105<br />
103<br />
100<br />
98<br />
96<br />
94<br />
91<br />
Belt drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 28.75 kgm 2<br />
Casing diameter d.i.L. = 1780 mm<br />
Outlet cross section A 2 = 2.49 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
90 000<br />
25<br />
10<br />
63<br />
100 000<br />
28<br />
11,2<br />
80<br />
112 000<br />
31,5<br />
12,5<br />
100<br />
125 000<br />
35,5<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/1800/R2<br />
Power limit Type R2 (132 kW) 0,81<br />
140 000<br />
40<br />
16<br />
160<br />
160 000<br />
45<br />
18<br />
200<br />
180 000<br />
50<br />
20<br />
250<br />
200 000<br />
56<br />
22,4<br />
315<br />
Type R1<br />
not available<br />
224 000<br />
63<br />
25<br />
250 000<br />
71<br />
28<br />
Type R2<br />
max. 132 kW<br />
280 000<br />
80<br />
31,5<br />
315 000<br />
90<br />
35,5<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
134<br />
95<br />
67<br />
48<br />
34<br />
24<br />
17<br />
12<br />
8.5<br />
6.0<br />
Fan speed n [rpm]<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
152<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Fans with operating point in grid area upon request * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
400<br />
� = 0,81<br />
0,77<br />
500<br />
0,69<br />
0,64<br />
630<br />
0,55<br />
800<br />
115<br />
112<br />
110<br />
108<br />
106<br />
103<br />
101<br />
99<br />
96<br />
94<br />
92
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 23 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 43.75 kgm 2<br />
Casing diameter d.i.L. = 1997 mm<br />
Outlet cross section A 2 = 3.13 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
112 000<br />
31,5<br />
10<br />
63<br />
125 000<br />
35,5<br />
11,2<br />
80<br />
Power limit Type R2 (132 kW)<br />
140 000<br />
40<br />
12,5<br />
100<br />
160 000<br />
45<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/56/2000/R2<br />
180 000<br />
50<br />
16<br />
160<br />
200 000<br />
56<br />
18<br />
200<br />
224 000<br />
63<br />
20<br />
250<br />
250 000<br />
71<br />
22,4<br />
315<br />
Type R1<br />
not available<br />
280 000<br />
80<br />
25<br />
315 000<br />
90<br />
28<br />
Type R2<br />
max. 132 kW<br />
355 000<br />
100<br />
31,5<br />
400 000<br />
112<br />
35,5<br />
Approx. shaftpower input<br />
requirement Pw [kW]<br />
168<br />
120<br />
84<br />
60<br />
44<br />
30<br />
22<br />
15<br />
11<br />
8.0<br />
Fan speed n [rpm]<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
153<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Fans with operating point in grid area upon request * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
0,81<br />
400<br />
� = 0,81<br />
0,77<br />
500<br />
0,69<br />
0,64<br />
630<br />
0,55<br />
800<br />
115<br />
113<br />
111<br />
109<br />
106<br />
104<br />
102<br />
100<br />
97<br />
95<br />
93<br />
Belt drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 25 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 58 kgm 2<br />
Casing diameter d.i.L. = 2228 mm<br />
Outlet cross section A 2 = 3.9 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
125 000<br />
35,5<br />
9,0<br />
50<br />
140 000<br />
40<br />
10<br />
63<br />
160 000<br />
45<br />
11,2<br />
80<br />
6,3<br />
180 000<br />
50<br />
12,5<br />
100<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/50/2240/R2<br />
200 000<br />
56<br />
14<br />
125<br />
Power limit<br />
Type R2 (132 kW)<br />
8,0<br />
224 000<br />
63<br />
16<br />
160<br />
250 000<br />
71<br />
18<br />
200<br />
10<br />
280 000<br />
80<br />
20<br />
250<br />
Type R1<br />
not available<br />
315 000<br />
90<br />
22,4<br />
355 000<br />
100<br />
25<br />
Type R2<br />
max. 132 kW<br />
400 000<br />
112<br />
28<br />
450 000<br />
125<br />
31,5<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
160<br />
125<br />
100<br />
80<br />
63<br />
50<br />
40<br />
31.5<br />
25<br />
20<br />
Fan speed n [rpm]<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
154<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Fans with operating point in grid area upon request * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
315<br />
0,82<br />
12,5<br />
400<br />
� = 0,82<br />
0,78<br />
500<br />
0,69<br />
16<br />
0,63<br />
0,50<br />
630<br />
117<br />
115<br />
112<br />
110<br />
108<br />
106<br />
103<br />
101<br />
99<br />
97<br />
95
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Total pressure increase � pt [Pa] ➞<br />
2 240<br />
2 000<br />
1 800<br />
1 600<br />
1 400<br />
1 250<br />
1 120<br />
1 000<br />
900<br />
800<br />
710<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
160<br />
140<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
Max possible motor size:<br />
cf dimensional diagrams<br />
The characteristic curves for a 30 deg. pitch angle<br />
Temperature t = 20 °C, Density = 1.2 kg/m 3<br />
Number of impeller blades: 12<br />
Moment of inertia I = 73.5 kgm 2<br />
Casing diameter d.i.L. = 2500 mm<br />
Outlet cross section A 2 = 4.9 m 2<br />
The characteristic curves were measured<br />
with a 2.5 D duct on the outlet side.<br />
Efficiency data apply to max. rpm<br />
180 000<br />
50<br />
10<br />
63<br />
200 000<br />
56<br />
11,2<br />
80<br />
224 000<br />
63<br />
12,5<br />
100<br />
9,0<br />
250 000<br />
71<br />
14<br />
125<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
BELT DRIVE<br />
TYPE AXN 12/45/2500/R2<br />
280 000<br />
80<br />
16<br />
160<br />
11,2<br />
Power limit<br />
Type R2 (200 kW)<br />
315 000<br />
90<br />
18<br />
200<br />
355 000<br />
100<br />
20<br />
250<br />
14<br />
400 000<br />
112<br />
22,4<br />
315<br />
Type R1<br />
not available<br />
450 000<br />
125<br />
25<br />
500 000<br />
140<br />
28<br />
Type R2<br />
max. 200 kW<br />
560 000<br />
160<br />
31,5<br />
630 000<br />
180<br />
35,5<br />
Approx. shaft power input<br />
requirement Pw [kW]<br />
224<br />
180<br />
140<br />
112<br />
90<br />
71<br />
56<br />
45<br />
35.5<br />
28<br />
Fan speed n [rpm]<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
Volume flow [m 3/h]<br />
Volume flow [m 3/s]<br />
Flow velocity<br />
C1 = C2 [m/s]<br />
Tip speed u [m/s]<br />
84<br />
74<br />
66<br />
59<br />
53<br />
47<br />
42<br />
38<br />
33<br />
30<br />
27<br />
155<br />
Total acoustic power<br />
level Lw [dB]<br />
Dynamic pressure pd [Pa]<br />
Fans with operating point in grid area upon request * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />
400<br />
0,80<br />
18<br />
500<br />
� = 0,82<br />
0,78<br />
0,74<br />
630<br />
22,4<br />
0,63<br />
800<br />
0,53<br />
119<br />
117<br />
114<br />
112<br />
110<br />
108<br />
105<br />
103<br />
101<br />
99<br />
97<br />
Belt drive
Item<br />
Nr.<br />
or<br />
or<br />
or<br />
or<br />
Qty. Description<br />
– 156 –<br />
<strong>Axial</strong> Flow Fan – AXN Series, Type R1<br />
Belt-drive type<br />
consisting of<br />
Casing of welded sheet steel construction<br />
with drilled flanges according to DIN 24 154, Series 3.<br />
Outlet guide vanes for boosting outlet pressure and<br />
achieving an essentially swirl-free outlet flow<br />
Surface protection:<br />
• Full paint finish, colour: RAL 7030<br />
Aluminium impeller, blade pitch steplessly adjustable<br />
when fan is at rest, driven via a shaft, with<br />
prelubricated double flange bearing support.<br />
Service life: approx. 20,000 operating hours;<br />
V-belt drive consisting of two pulleys and one<br />
electrically conducting V-belt.<br />
Motor mounting with adjustment carriage to facilitate<br />
belt tightening operation.<br />
Outlet-side installation:<br />
• Duct connection<br />
• Direct outlet without diffuser<br />
• Outlet into diffuser (optional)<br />
Specifications<br />
Volume flow m3/h Dynamic inlet pressure Pa<br />
Dynamic outlet pressure Pa<br />
Total pressure increase of fan Pa<br />
Pressure loss of accessories Pa<br />
External pressure loss Pa<br />
Temperature °C<br />
Density kg/m3 Fan rotational speed rpm<br />
Blade pitch angle °<br />
Total acoustic power level L w<br />
dB<br />
Efficiency %<br />
Power required at shaft kW<br />
Three-phase a.c. motor<br />
• single speed<br />
• Dahlander pole-changing type<br />
• pole-changing type with seperate windings<br />
Motor speed rpm<br />
Motor output kW<br />
Current consumption A<br />
Voltage Volt<br />
Frequency Hz<br />
Protection class IP<br />
Type B<br />
Size<br />
Weight kg<br />
Manufacturer: <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Type: AXN 12/56/ ..........R1<br />
Carryover<br />
Unit price<br />
2<br />
Total<br />
2
Item<br />
Nr.<br />
Qty. Description<br />
Options:<br />
• Electric motor<br />
– 157 –<br />
• Exterior terminal box wired to electric motor<br />
• Assembly cost for supplied motor<br />
• Galvanized fan<br />
• Fan with special coating<br />
• Bellmouth inlet with flange<br />
• Wire guard on bellmouth or motor side<br />
• Wire guard on extension casing<br />
• Flexible connector, inlet side *<br />
• Flexible connector, outlet side *<br />
• Matching flange *<br />
• Angular wall ring with brackets *<br />
• Set of mounting feet (2 pcs.) *<br />
• Set of rubber antivibration mounts *<br />
• Set of spring-type antivibration mounts *<br />
• Brackets for vertical fan installation<br />
Carryover<br />
• Spark-proof equipment (hazardous-duty models only)<br />
• Diffuser with interior core *<br />
• Round silencer, TSR type *<br />
Note: Please see our Installation, Operating<br />
and Maintenance Instructions<br />
available upon request.<br />
* Loosely supplied<br />
Unit price<br />
2<br />
Total<br />
2<br />
Belt drive
Item<br />
Nr.<br />
or<br />
or<br />
or<br />
or<br />
Qty. Description<br />
– 158 –<br />
<strong>Axial</strong> Flow Fan - AXN Series, Type R2<br />
Belt-drive type<br />
consisting of<br />
Casing of welded sheet steel construction<br />
with drilled flanges according to DIN 24 154, Series 4.<br />
Outlet guide vanes for boosting outlet pressure and<br />
achieving an essentially swirl-free outlet flow<br />
Surface protection:<br />
• Full paint finish, colour: RAL 7030<br />
Aluminium impeller, blade pitch steplessly adjustable<br />
when fan is at rest, driven via a shaft supported in<br />
two separate antifriction bearings.<br />
Antifriction bearings with grease valve and re-lubrication device,<br />
service life: approx. 50,000 operating hours.<br />
V-belt drive consisting of two pulleys and one electrically<br />
conducting V-belt.<br />
Motor mounting with adjustment carriage to facilitate<br />
belt tightening operation.<br />
Outlet-side installation:<br />
• Duct connection<br />
• Direct outlet without diffuser<br />
• Outlet into diffuser (optional)<br />
Specifications<br />
Volume flow m3/h Dynamic inlet pressure Pa<br />
Dynamic outlet pressure Pa<br />
Total pressure increase of fan Pa<br />
Pressure loss of accessories Pa<br />
External pressure loss Pa<br />
Temperature °C<br />
Density kg/m3 Fan rotational speed rpm<br />
Blade pitch angle °<br />
Total acoustic power level L w<br />
dB<br />
Efficiency %<br />
Power required at shaft kW<br />
Three-phase a.c. motor<br />
• single speed<br />
• Dahlander pole-changing type<br />
• pole-changing type with seperate windings<br />
Motor speed rpm<br />
Motor output kW<br />
Current consumption A<br />
Voltage Volt<br />
Frequency Hz<br />
Protection class IP<br />
Type B<br />
Size<br />
Weight kg<br />
Manufacturer: <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Type: AXN 12/56/ ..........R2<br />
Carryover<br />
Unit price<br />
2<br />
Total<br />
2
Item<br />
Nr.<br />
Qty. Description<br />
Options:<br />
• Electric motor<br />
– 159 –<br />
• Exterior terminal box wired to electric motor<br />
• Assembly cost for supplied motor<br />
• Galvanized fan<br />
• Fan with special coating<br />
• Bellmouth inlet with flange<br />
• Wire guard on bellmouth or motor side<br />
• Wire guard on extension casing<br />
• Flexible connector, inlet side *<br />
• Flexible connector, outlet side *<br />
• Matching flange *<br />
• Angular wall ring with brackets *<br />
• Set of mounting feet (2 pcs.) *<br />
• Set of rubber antivibration mounts *<br />
• Set of spring-type antivibration mounts *<br />
• Brackets for vertical fan installation<br />
Carryover<br />
• Spark-proof equipment (hazardous-duty models only)<br />
• Diffuser with interior core *<br />
• Round silencer, TSR type *<br />
Note: Please see our Installation, Operating<br />
and Maintenance Instructions<br />
available upon request.<br />
* Loosely supplied<br />
Unit price<br />
2<br />
Total<br />
2<br />
Belt drive
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
Forced-draught tubular heat exchangers<br />
equipped with AXN 12/56/100/M-S axialflow<br />
fans (high-efficiency filtration)<br />
AXN 12/56/710 M-D axial-flow fan<br />
with accessories: Extension casing, bellmouth<br />
inlet with wire guard and mounting feet.<br />
AXIAL FLOW FANS<br />
APPLICATION EXAMPLES / REFERENCES<br />
163<br />
Type AXN 12/56/1600 R2 axial-flow fans in the air conditioning centre of a large office building<br />
(Hamburg-Mannheimer Versicherung)<br />
AXN 12/56/500 M-D axial-flow fans cooling a tobacco warehouse<br />
(Bremer Lagerhaus-Gesellschaft)<br />
Two-stage axial flow fans, e.g., for car park ventilation or operation against high pressures, are a<br />
recent addition to our product range. These units are also available for 200° C / 300° C or 400° C<br />
– 120 min. operation (tested to EN 12101 – T3 standard specifications).
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Building and Tunnel Fans Division<br />
Am Weinberg 68<br />
D-36251 Bad Hersfeld/Germany<br />
Phone: + 49.6621.950-0<br />
Fax: + 49.6621.950-100<br />
E-mail: serie@tlt.de<br />
Website: www.tlt.de<br />
© 2007 - <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong> · 13th edition 02/07/0.8 · Subject to errors and modifications.