Axial innen engl - TLT Turbo GmbH
Axial innen engl - TLT Turbo GmbH
Axial innen engl - TLT Turbo GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
630<br />
560<br />
500<br />
450<br />
400<br />
355<br />
315<br />
280<br />
250<br />
224<br />
200<br />
180<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
2800<br />
0,8<br />
6,3<br />
25<br />
3150<br />
0,9<br />
7,1<br />
31,5<br />
25°<br />
3550<br />
1,0<br />
8,0<br />
40<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 8/400/D*<br />
ROTATIONAL SPEED 2870 RPM<br />
Tip speed u2 = 60 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m3 4000<br />
1,12<br />
9,0<br />
50<br />
30°<br />
4500<br />
1,25<br />
10<br />
63<br />
�<br />
5000<br />
1,4<br />
11,2<br />
80<br />
25°<br />
5600<br />
1,6<br />
12,5<br />
100<br />
35°<br />
0,50<br />
0,48<br />
6300<br />
1,8<br />
14<br />
125<br />
40°<br />
0,53<br />
7100<br />
2,0<br />
16<br />
160<br />
30°<br />
8000<br />
2,24<br />
18<br />
200<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 401 mm<br />
Outlet cross section A2 = 0,126 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
A hazardous-duty version is available<br />
only with 35° blade angle.<br />
45°<br />
� =<br />
0,54 pd<br />
9000<br />
2,5<br />
20<br />
250<br />
40°<br />
10000<br />
2,8<br />
22,4<br />
315<br />
11200<br />
3,15<br />
25<br />
400<br />
107<br />
105<br />
103<br />
101<br />
99<br />
97<br />
95<br />
93<br />
91<br />
89<br />
87<br />
047<br />
45° Blade pitch angle<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
35°<br />
AXO-Direct-drive