27.02.2013 Views

Axial innen engl - TLT Turbo GmbH

Axial innen engl - TLT Turbo GmbH

Axial innen engl - TLT Turbo GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />

Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />

˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />

pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />

c = Flow velocity [m/s]<br />

Total pressure increase � pt [Pa] →<br />

112<br />

100<br />

90<br />

80<br />

71<br />

63<br />

56<br />

50<br />

45<br />

40<br />

35,5<br />

31,5<br />

Shaft power input requirement:<br />

V [m<br />

Pw [kW] = =<br />

3 ·<br />

/h] · �pt [Pa]<br />

�· 1000 · 3600<br />

710<br />

0,2<br />

2,5<br />

4,0<br />

800<br />

0,224<br />

900<br />

0,25<br />

CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />

DIRECT DRIVE, WITHOUT GUIDE VANES<br />

TYPE AXO 8/315/D*<br />

ROTATIONAL SPEED 1450 RPM<br />

Tip speed u 2 = 23 m/s<br />

Temperature t = 20°C<br />

Density = 1,2 kg/m 3<br />

1000<br />

0,28<br />

�<br />

1120<br />

0,315<br />

1250<br />

0,355<br />

1400<br />

0,4<br />

1600<br />

0,45<br />

1800<br />

0,5<br />

2000<br />

0,56<br />

Moment of inertia I = kg m 2<br />

Casing diameter d.i.L. = 320 mm<br />

Outlet cross section A2 = 0,08 m 2<br />

These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />

A hazardous-duty version is available<br />

only with 35° blade angle.<br />

2,8<br />

5,0<br />

25°<br />

3,15<br />

6,3<br />

3,55<br />

8,0<br />

4,0<br />

10<br />

30°<br />

4,5<br />

12,5<br />

5,0<br />

16<br />

5,6<br />

20<br />

6,3<br />

25<br />

7,1<br />

31,5<br />

2240<br />

0,63<br />

8,0<br />

40<br />

2500<br />

0,71<br />

9,0<br />

50<br />

2800<br />

0,8<br />

10<br />

63<br />

89<br />

87<br />

85<br />

83<br />

81<br />

79<br />

77<br />

75<br />

73<br />

71<br />

69<br />

044<br />

˙V [m 3 /h] →<br />

˙V [m 3 /s] →<br />

c [m/s] →<br />

pd [Pa] →<br />

Total acoustic power level<br />

Lw [dB]<br />

* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />

25°<br />

35°<br />

� =<br />

0,49<br />

0,32<br />

40°<br />

0,46<br />

30°<br />

0,43<br />

0,40<br />

45°<br />

35°<br />

40°<br />

pd<br />

45° Blade pitch angle

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!