˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase � pt [Pa] →<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
40<br />
35,5<br />
31,5<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
710<br />
0,2<br />
2,5<br />
4,0<br />
800<br />
0,224<br />
900<br />
0,25<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITHOUT GUIDE VANES<br />
TYPE AXO 8/315/D*<br />
ROTATIONAL SPEED 1450 RPM<br />
Tip speed u 2 = 23 m/s<br />
Temperature t = 20°C<br />
Density = 1,2 kg/m 3<br />
1000<br />
0,28<br />
�<br />
1120<br />
0,315<br />
1250<br />
0,355<br />
1400<br />
0,4<br />
1600<br />
0,45<br />
1800<br />
0,5<br />
2000<br />
0,56<br />
Moment of inertia I = kg m 2<br />
Casing diameter d.i.L. = 320 mm<br />
Outlet cross section A2 = 0,08 m 2<br />
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />
A hazardous-duty version is available<br />
only with 35° blade angle.<br />
2,8<br />
5,0<br />
25°<br />
3,15<br />
6,3<br />
3,55<br />
8,0<br />
4,0<br />
10<br />
30°<br />
4,5<br />
12,5<br />
5,0<br />
16<br />
5,6<br />
20<br />
6,3<br />
25<br />
7,1<br />
31,5<br />
2240<br />
0,63<br />
8,0<br />
40<br />
2500<br />
0,71<br />
9,0<br />
50<br />
2800<br />
0,8<br />
10<br />
63<br />
89<br />
87<br />
85<br />
83<br />
81<br />
79<br />
77<br />
75<br />
73<br />
71<br />
69<br />
044<br />
˙V [m 3 /h] →<br />
˙V [m 3 /s] →<br />
c [m/s] →<br />
pd [Pa] →<br />
Total acoustic power level<br />
Lw [dB]<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
25°<br />
35°<br />
� =<br />
0,49<br />
0,32<br />
40°<br />
0,46<br />
30°<br />
0,43<br />
0,40<br />
45°<br />
35°<br />
40°<br />
pd<br />
45° Blade pitch angle