Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
˙V = Volume flow [m 3 /h] or [m 3 /s]<br />
pd = Dynamic pressure [Pa] or x 0.1 [kp/m 2 ]<br />
c = Flow velocity [m/s]<br />
Total pressure increase �pt [Pa] ➞<br />
125<br />
112<br />
100<br />
90<br />
80<br />
71<br />
63<br />
56<br />
50<br />
45<br />
40<br />
with duct 2.5 D<br />
direct outlet<br />
Shaft power input requirement:<br />
V [m<br />
Pw [kW] = =<br />
3 ·<br />
/h] · �pt [Pa]<br />
�· 1000 · 3600<br />
85DP008A_s32.ai<br />
5°<br />
0°<br />
630<br />
0,18<br />
2,24<br />
3,15<br />
3,15<br />
6,3<br />
710<br />
0,2<br />
2,5<br />
4,0<br />
3,55<br />
8,0<br />
0,36<br />
800<br />
0,224<br />
2,8<br />
5,0<br />
4,0<br />
10<br />
0,41<br />
Tip speed u 2 = 23 m/s<br />
Temperature t = 20° C<br />
Density = 1.2 kg/m 3<br />
900<br />
0,25<br />
3,15<br />
6,3<br />
4,5<br />
12,5<br />
1 000<br />
0,28<br />
3,55<br />
8,0<br />
5,0<br />
16<br />
0,46<br />
1 120<br />
0,315<br />
4,0<br />
10<br />
5,6<br />
20<br />
1 250<br />
0,355<br />
4,5<br />
12,5<br />
6,3<br />
25<br />
0,49<br />
1 400<br />
0,4<br />
5,0<br />
16<br />
7,1<br />
31,5<br />
1 600<br />
0,45<br />
5,6<br />
20<br />
8,0<br />
40<br />
Moment of inertia I = 0,007 kg m 2<br />
Casing diameter d.i.L. = 320 mm<br />
Outlet cross section A 2 = 0.08 m 2<br />
1 800<br />
0,5<br />
6,3<br />
25<br />
9,0<br />
50<br />
� = 0,40<br />
15°<br />
0° 0° 5° 5° 10° 10° 15° 20° 25°<br />
10°<br />
CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />
DIRECT DRIVE, WITH OUTLET GUIDE VANES<br />
TYPE AXN 12/56/315/D*<br />
ROTATIONAL SPEED 1360 RPM<br />
15°<br />
20°<br />
2 000<br />
0,56<br />
7,1<br />
31,5<br />
10<br />
63<br />
0,37<br />
pd<br />
25°<br />
0,27<br />
2 240<br />
0,63<br />
8,0<br />
40<br />
11,2<br />
80<br />
0,32<br />
2 500<br />
0,71<br />
9,0<br />
50<br />
12,5<br />
100<br />
pd<br />
83<br />
82<br />
81<br />
80<br />
79<br />
78<br />
77<br />
76<br />
75<br />
74<br />
73<br />
091<br />
35°<br />
Blade Schaufelwinkel pitch angle<br />
30°<br />
[m 3/h] ➞<br />
[m 3/s] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
c [m/s] ➞<br />
pd [Pa] ➞<br />
* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />
20°<br />
25°<br />
30°<br />
A 1 = 0.055 m 2<br />
35°<br />
Total acoustic power level L w [dB]<br />
AXN-Direct drive