27.02.2013 Views

Axial innen engl - TLT Turbo GmbH

Axial innen engl - TLT Turbo GmbH

Axial innen engl - TLT Turbo GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

01.01<br />

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />

Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />

Total pressure increase pt [Pa]<br />

5000<br />

4000<br />

3150<br />

2500<br />

2000<br />

1600<br />

1250<br />

1000<br />

800<br />

630<br />

500<br />

400<br />

315<br />

250<br />

200<br />

160<br />

125<br />

100<br />

80<br />

R1 Type<br />

R2 Type<br />

AXN series – with outlet guide vanes<br />

– belt-drive<br />

– 12 impeller blades<br />

– airflow direction "D"<br />

AXN 12/56/400<br />

AXN 12/56/450<br />

AXN 12/56/500<br />

Volume flow V · [m 3 /h]<br />

AXN 12/56/560<br />

AXIAL FLOW FANS AXN SERIES<br />

BELT DRIVE<br />

PRE-SELECTION DIAGRAMS<br />

RANGE OF APPLICATION / USE<br />

AXN 12/56/630<br />

AXN 12/56/710<br />

Sizes / Hub ratio<br />

With hub ratio 0.56<br />

15 Sizes 400 to 2000 dia.<br />

With hub ratio 0.50<br />

2 Sizes 2000 and 2240 dia.<br />

With hub ratio 0.45<br />

1 Size 2500 dia.<br />

AXN 12/56/800<br />

AXN 12/56/900<br />

AXN 12/56/1000<br />

AXN 12/56/1120<br />

AXN 12/56/1250<br />

Number of blades<br />

12 impeller blades on all versions<br />

(for characteristic curves refer to the<br />

catalogue)<br />

An optimum adjustment to the required<br />

operating point is achieved via<br />

the fan speed by changing the belt<br />

transmission ratio.<br />

Range of Application<br />

From small volume flows against low<br />

pressures to very large volume flows<br />

against high pressures.<br />

V · = approx. 4000 to 560 000 m 3 /h<br />

� pt = approx. 80 Pa to 1800 Pa<br />

AXN 12/56/1400<br />

AXN 12/56/1600<br />

AXN 12/50/2000<br />

AXN 12/56/1800<br />

AXN 12/50/2240<br />

AXN 12/56/2000<br />

AXN 12/45/2500<br />

5600<br />

6300<br />

7100<br />

8000<br />

9000<br />

10000<br />

11200<br />

12500<br />

14000<br />

16000<br />

18000<br />

20000<br />

22400<br />

25000<br />

28000<br />

31500<br />

35500<br />

40000<br />

45000<br />

50000<br />

56000<br />

63000<br />

71000<br />

80000<br />

90000<br />

100000<br />

112000<br />

125000<br />

140000<br />

160000<br />

180000<br />

200000<br />

224000<br />

250000<br />

280000<br />

315000<br />

355000<br />

400000<br />

450000<br />

500000<br />

560000<br />

Die Leistungsgrenzen der<br />

Bauformen R1 und R2 bitte den<br />

Kennlinienblättern entnehmen.<br />

033<br />

Density: 1.2 kg/m3 Temperature: 20 °C<br />

Use<br />

Ventilation systems, air conditioning,<br />

large air supply and extraction centers.<br />

In these environments these fans are<br />

particularly suitable for installation in<br />

equipment, conventional air conditioning<br />

centers, or sandwich-type<br />

center configurations.<br />

For characteristic curves<br />

refer to pages 139 - 155