R1 Type<br />
R2 Type<br />
AXN series – with outlet guide vanes<br />
– belt-drive<br />
– 12 impeller blades<br />
– airflow direction "D"<br />
AXN 12/56/400<br />
AXN 12/56/450<br />
AXN 12/56/500<br />
Volume flow V · [m 3 /h]<br />
AXN 12/56/560<br />
AXIAL FLOW FANS AXN SERIES<br />
BELT DRIVE<br />
PRE-SELECTION DIAGRAMS<br />
RANGE OF APPLICATION / USE<br />
AXN 12/56/630<br />
AXN 12/56/710<br />
Sizes / Hub ratio<br />
With hub ratio 0.56<br />
15 Sizes 400 to 2000 dia.<br />
With hub ratio 0.50<br />
2 Sizes 2000 and 2240 dia.<br />
With hub ratio 0.45<br />
1 Size 2500 dia.<br />
AXN 12/56/800<br />
AXN 12/56/900<br />
AXN 12/56/1000<br />
AXN 12/56/1120<br />
AXN 12/56/1250<br />
Number of blades<br />
12 impeller blades on all versions<br />
(for characteristic curves refer to the<br />
catalogue)<br />
An optimum adjustment to the required<br />
operating point is achieved via<br />
the fan speed by changing the belt<br />
transmission ratio.<br />
Range of Application<br />
From small volume flows against low<br />
pressures to very large volume flows<br />
against high pressures.<br />
V · = approx. 4000 to 560 000 m 3 /h<br />
� pt = approx. 80 Pa to 1800 Pa<br />
AXN 12/56/1400<br />
AXN 12/56/1600<br />
AXN 12/50/2000<br />
AXN 12/56/1800<br />
AXN 12/50/2240<br />
AXN 12/56/2000<br />
AXN 12/45/2500<br />
5600<br />
6300<br />
7100<br />
8000<br />
9000<br />
10000<br />
11200<br />
12500<br />
14000<br />
16000<br />
18000<br />
20000<br />
22400<br />
25000<br />
28000<br />
31500<br />
35500<br />
40000<br />
45000<br />
50000<br />
56000<br />
63000<br />
71000<br />
80000<br />
90000<br />
100000<br />
112000<br />
125000<br />
140000<br />
160000<br />
180000<br />
200000<br />
224000<br />
250000<br />
280000<br />
315000<br />
355000<br />
400000<br />
450000<br />
500000<br />
560000<br />
Die Leistungsgrenzen der<br />
Bauformen R1 und R2 bitte den<br />
Kennlinienblättern entnehmen.<br />
033<br />
Density: 1.2 kg/m3 Temperature: 20 °C<br />
Use<br />
Ventilation systems, air conditioning,<br />
large air supply and extraction centers.<br />
In these environments these fans are<br />
particularly suitable for installation in<br />
equipment, conventional air conditioning<br />
centers, or sandwich-type<br />
center configurations.<br />
For characteristic curves<br />
refer to pages 139 - 155