27.02.2013 Views

Axial innen engl - TLT Turbo GmbH

Axial innen engl - TLT Turbo GmbH

Axial innen engl - TLT Turbo GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />

Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />

˙V = Volume flow [m 3 /h] bzw. [m 3 /s]<br />

pd = Dynamic pressure [Pa] or x 0,1 [kp/m 2 ]<br />

c = Flow velocity [m/s]<br />

Total pressure increase � pt [Pa] →<br />

224<br />

200<br />

180<br />

160<br />

140<br />

125<br />

112<br />

100<br />

90<br />

80<br />

71<br />

63<br />

Shaft power input requirement:<br />

V [m<br />

Pw [kW] = =<br />

3 ·<br />

/h] · �pt [Pa]<br />

�· 1000 · 3600<br />

30°<br />

16 000<br />

4,5<br />

4,5<br />

12,5<br />

18 000<br />

5,0<br />

5,0<br />

16<br />

20 000<br />

5,6<br />

5,6<br />

20<br />

35°<br />

CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />

DIRECT DRIVE, WITHOUT GUIDE VANES<br />

TYPE AXO 12/1120/D*<br />

ROTATIONAL SPEED 740 RPM<br />

Tip speed u2 = 42 m/s<br />

Temperature t = 20°C<br />

Density = 1,2 kg/m3 22 400<br />

6,3<br />

6,3<br />

25<br />

30°<br />

�<br />

25 000<br />

7,1<br />

7,1<br />

31,5<br />

32,5°<br />

28 000<br />

8,0<br />

8,0<br />

40<br />

40°<br />

32,5°<br />

0,47<br />

31 500<br />

9,0<br />

9,0<br />

50<br />

0,49<br />

35°<br />

35 500<br />

10<br />

10<br />

63<br />

40 000<br />

11,2<br />

11,2<br />

80<br />

37,5°<br />

37,5°<br />

0,53<br />

0,51<br />

40°<br />

45 000<br />

12,5<br />

12,5<br />

100<br />

Moment of inertia I = kg m 2<br />

Casing diameter d.i.L. = 1124 mm<br />

Outlet cross section A2 = 1,0 m 2<br />

These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.<br />

� =<br />

0,56<br />

50 000<br />

14<br />

14<br />

125<br />

45°<br />

45°<br />

pd<br />

56 000<br />

16<br />

16<br />

160<br />

50° Blade pitch angle<br />

50°<br />

63 000<br />

18<br />

18<br />

200<br />

105<br />

103<br />

101<br />

99<br />

97<br />

95<br />

93<br />

91<br />

89<br />

87<br />

85<br />

063<br />

˙V [m 3 /h] →<br />

˙V [m 3 /s] →<br />

c [m/s] →<br />

pd [Pa] →<br />

Total acoustic power level<br />

Lw [dB]<br />

* Airflow direction D (motor in outlet) – Please inquire for Airflow direction S (motor in inlet) Values rounded to standard figures.<br />

AXO-Direct-drive

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!