27.02.2013 Views

Axial innen engl - TLT Turbo GmbH

Axial innen engl - TLT Turbo GmbH

Axial innen engl - TLT Turbo GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />

Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />

Total pressure increase � pt [Pa] ➞<br />

2 240<br />

2 000<br />

1 800<br />

1 600<br />

1 400<br />

1 250<br />

1 120<br />

1 000<br />

900<br />

800<br />

710<br />

630<br />

560<br />

500<br />

450<br />

400<br />

355<br />

315<br />

280<br />

250<br />

224<br />

200<br />

180<br />

160<br />

140<br />

125<br />

112<br />

100<br />

90<br />

80<br />

71<br />

Max possible motor size:<br />

cf dimensional diagrams<br />

The characteristic curves for a 30 deg. pitch angle<br />

Temperature t = 20 °C, Density = 1.2 kg/m 3<br />

Number of impeller blades: 12<br />

Moment of inertia I = 73.5 kgm 2<br />

Casing diameter d.i.L. = 2500 mm<br />

Outlet cross section A 2 = 4.9 m 2<br />

The characteristic curves were measured<br />

with a 2.5 D duct on the outlet side.<br />

Efficiency data apply to max. rpm<br />

180 000<br />

50<br />

10<br />

63<br />

200 000<br />

56<br />

11,2<br />

80<br />

224 000<br />

63<br />

12,5<br />

100<br />

9,0<br />

250 000<br />

71<br />

14<br />

125<br />

CHARACTERISTIC CURVES – AXIAL FLOW FANS<br />

BELT DRIVE<br />

TYPE AXN 12/45/2500/R2<br />

280 000<br />

80<br />

16<br />

160<br />

11,2<br />

Power limit<br />

Type R2 (200 kW)<br />

315 000<br />

90<br />

18<br />

200<br />

355 000<br />

100<br />

20<br />

250<br />

14<br />

400 000<br />

112<br />

22,4<br />

315<br />

Type R1<br />

not available<br />

450 000<br />

125<br />

25<br />

500 000<br />

140<br />

28<br />

Type R2<br />

max. 200 kW<br />

560 000<br />

160<br />

31,5<br />

630 000<br />

180<br />

35,5<br />

Approx. shaft power input<br />

requirement Pw [kW]<br />

224<br />

180<br />

140<br />

112<br />

90<br />

71<br />

56<br />

45<br />

35.5<br />

28<br />

Fan speed n [rpm]<br />

630<br />

560<br />

500<br />

450<br />

400<br />

355<br />

315<br />

280<br />

250<br />

224<br />

200<br />

Volume flow [m 3/h]<br />

Volume flow [m 3/s]<br />

Flow velocity<br />

C1 = C2 [m/s]<br />

Tip speed u [m/s]<br />

84<br />

74<br />

66<br />

59<br />

53<br />

47<br />

42<br />

38<br />

33<br />

30<br />

27<br />

155<br />

Total acoustic power<br />

level Lw [dB]<br />

Dynamic pressure pd [Pa]<br />

Fans with operating point in grid area upon request * Airflow direction D (motor in outlet) – values rounded to standard figures.<br />

400<br />

0,80<br />

18<br />

500<br />

� = 0,82<br />

0,78<br />

0,74<br />

630<br />

22,4<br />

0,63<br />

800<br />

0,53<br />

119<br />

117<br />

114<br />

112<br />

110<br />

108<br />

105<br />

103<br />

101<br />

99<br />

97<br />

Belt drive