Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
AXN SERIES with outlet<br />
Guide Vanes<br />
Technical Description<br />
High output and broad operationg<br />
poing adaptability are key features of<br />
all fans of this series.<br />
■ 21 available design sizes with casing<br />
diameters from 250 to 2500<br />
mm<br />
■ Two basic designs for direct drive<br />
(M) or belt drive (R).<br />
■ From optimum pressure coefficiets<br />
this series is equipped with outlet<br />
guide vanes.<br />
■ impeller blades are steplessly<br />
pitch-adjustable without having to<br />
remove the impeller from the unit.<br />
Post-installation adjustments to<br />
specific operating points within the<br />
motor output range can thus be easily<br />
made.<br />
■ Impellers can be supplied with 12,<br />
9, 8, 6 or 4 blades (important particularly<br />
for direct-driven fans).<br />
■ The impeller material is cast solumin,<br />
with the exception of the clamping<br />
strap which consists fo AlMg<br />
3F-2. A high weather and seawater<br />
resistance is thus ensured.<br />
■ On R1 and R2 (belt driven) types,<br />
an additional operatiin point matching<br />
feature is available via the<br />
“stepless“ impeller rpm adjustment<br />
which can be achieved by changing<br />
the belt transmission ratio.<br />
■ High pressure coefficients permit<br />
low tip speeds for minimum operating<br />
noise.<br />
■ Efficiencies up to 82%<br />
■ Tip speeds up to 85 m/s<br />
■ Direct-driven fans are normally<br />
supplied as airflow direction “D“<br />
(outlet over motor) designs. In special<br />
cases, airflow direction “S“<br />
Unless special precautions are<br />
taken, these axial-flow fans are not<br />
suitable for outdoor installation (enquiries<br />
to be directed to our headquarters).<br />
AXIAL FLOW FANS<br />
AXO SERIES - WITHOUT GUIDE VANES<br />
AXN SERIES - WITH OUTLET GUIDE VANES<br />
TECHNICAL DESCRIPTION<br />
(inlet over motor) types are available.<br />
The dimensioning for airflow direction<br />
“S“ axial-flow fans is done<br />
by our field representatives or at<br />
our company headquarters.<br />
■ Their compact design allows these<br />
fans to be installed even where<br />
space is at a premium.<br />
■ All fans are powered by IEC standard<br />
motors. Motors with thermocouples<br />
or thermistor sensors are<br />
available upon request.<br />
■ Standard units are rated for up to<br />
80°C, depending on motor insulation<br />
class.<br />
■ Casings up to size 1250 are made<br />
of deep-drawing grade sheet steel<br />
with pressed flanges.<br />
■ Fans up to size 1205 are surface-finished<br />
with a RAL 7030 (pebblegrey)<br />
polyester powder coating. As<br />
of size 1400, fans are supplied finispainted<br />
in RAL 7030 (pebble-grey)<br />
colour.<br />
AXO Series<br />
without Guid Vanes<br />
Technical Description<br />
006<br />
■ 7 design size with casing diameters<br />
from 315 to 1120 mm.<br />
■ Available as type “M“ for direct<br />
drive.<br />
■ Not designed for subsequent impeller<br />
blade adjustment.<br />
■ Built with 5, 8, 9 or 12 blades, depending<br />
on specified output<br />
■ Aluminium impeller hub with plastic<br />
blades.<br />
■ Up to 68% efficiency.<br />
■ Tip speeds up to 82 m/s<br />
■ Direct-driven fans are normally<br />
supplied as airflow direction “D“<br />
(outlet over motor) designs. In special<br />
cases, airflow direction “S“<br />
(inlet over motor) types are available.<br />
The demensionins ofor airflow<br />
directions “S“ axial-flow fans is<br />
done by our field representatives or<br />
at company headquarters.<br />
■ Their compact design allows these<br />
fans to be installed even where<br />
space is at a premium.<br />
■ All fans are powered by IEC standard<br />
motors. Motors with thermocouples<br />
or thermisotor sensors are<br />
available upon request.<br />
■ Standard units are rated for up to<br />
60°C, depending on motor insulation<br />
class<br />
■ Casings up to size 1120 are made<br />
of deep-drawing grade sheet steel<br />
with pressed flanges.<br />
■ Units are surface-finished with a<br />
RAL 7030 (pebble-grey) polyester<br />
powder coatching.<br />
For planning and installation, please<br />
also refer to our Installation,<br />
Operating and Maintenance<br />
Instructions (MBW).