Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />

Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />

AXN SERIES with outlet<br />

Guide Vanes<br />

Technical Description<br />

High output and broad operationg<br />

poing adaptability are key features of<br />

all fans of this series.<br />

■ 21 available design sizes with casing<br />

diameters from 250 to 2500<br />

mm<br />

■ Two basic designs for direct drive<br />

(M) or belt drive (R).<br />

■ From optimum pressure coefficiets<br />

this series is equipped with outlet<br />

guide vanes.<br />

■ impeller blades are steplessly<br />

pitch-adjustable without having to<br />

remove the impeller from the unit.<br />

Post-installation adjustments to<br />

specific operating points within the<br />

motor output range can thus be easily<br />

made.<br />

■ Impellers can be supplied with 12,<br />

9, 8, 6 or 4 blades (important particularly<br />

for direct-driven fans).<br />

■ The impeller material is cast solumin,<br />

with the exception of the clamping<br />

strap which consists fo AlMg<br />

3F-2. A high weather and seawater<br />

resistance is thus ensured.<br />

■ On R1 and R2 (belt driven) types,<br />

an additional operatiin point matching<br />

feature is available via the<br />

“stepless“ impeller rpm adjustment<br />

which can be achieved by changing<br />

the belt transmission ratio.<br />

■ High pressure coefficients permit<br />

low tip speeds for minimum operating<br />

noise.<br />

■ Efficiencies up to 82%<br />

■ Tip speeds up to 85 m/s<br />

■ Direct-driven fans are normally<br />

supplied as airflow direction “D“<br />

(outlet over motor) designs. In special<br />

cases, airflow direction “S“<br />

Unless special precautions are<br />

taken, these axial-flow fans are not<br />

suitable for outdoor installation (enquiries<br />

to be directed to our headquarters).<br />

AXIAL FLOW FANS<br />

AXO SERIES - WITHOUT GUIDE VANES<br />

AXN SERIES - WITH OUTLET GUIDE VANES<br />

TECHNICAL DESCRIPTION<br />

(inlet over motor) types are available.<br />

The dimensioning for airflow direction<br />

“S“ axial-flow fans is done<br />

by our field representatives or at<br />

our company headquarters.<br />

■ Their compact design allows these<br />

fans to be installed even where<br />

space is at a premium.<br />

■ All fans are powered by IEC standard<br />

motors. Motors with thermocouples<br />

or thermistor sensors are<br />

available upon request.<br />

■ Standard units are rated for up to<br />

80°C, depending on motor insulation<br />

class.<br />

■ Casings up to size 1250 are made<br />

of deep-drawing grade sheet steel<br />

with pressed flanges.<br />

■ Fans up to size 1205 are surface-finished<br />

with a RAL 7030 (pebblegrey)<br />

polyester powder coating. As<br />

of size 1400, fans are supplied finispainted<br />

in RAL 7030 (pebble-grey)<br />

colour.<br />

AXO Series<br />

without Guid Vanes<br />

Technical Description<br />

006<br />

■ 7 design size with casing diameters<br />

from 315 to 1120 mm.<br />

■ Available as type “M“ for direct<br />

drive.<br />

■ Not designed for subsequent impeller<br />

blade adjustment.<br />

■ Built with 5, 8, 9 or 12 blades, depending<br />

on specified output<br />

■ Aluminium impeller hub with plastic<br />

blades.<br />

■ Up to 68% efficiency.<br />

■ Tip speeds up to 82 m/s<br />

■ Direct-driven fans are normally<br />

supplied as airflow direction “D“<br />

(outlet over motor) designs. In special<br />

cases, airflow direction “S“<br />

(inlet over motor) types are available.<br />

The demensionins ofor airflow<br />

directions “S“ axial-flow fans is<br />

done by our field representatives or<br />

at company headquarters.<br />

■ Their compact design allows these<br />

fans to be installed even where<br />

space is at a premium.<br />

■ All fans are powered by IEC standard<br />

motors. Motors with thermocouples<br />

or thermisotor sensors are<br />

available upon request.<br />

■ Standard units are rated for up to<br />

60°C, depending on motor insulation<br />

class<br />

■ Casings up to size 1120 are made<br />

of deep-drawing grade sheet steel<br />

with pressed flanges.<br />

■ Units are surface-finished with a<br />

RAL 7030 (pebble-grey) polyester<br />

powder coatching.<br />

For planning and installation, please<br />

also refer to our Installation,<br />

Operating and Maintenance<br />

Instructions (MBW).