Axial innen engl - TLT Turbo GmbH
Axial innen engl - TLT Turbo GmbH
Axial innen engl - TLT Turbo GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany<br />
Phone: +49.6621.950-0 · Fax: +49.6621.950-100<br />
<strong>Axial</strong> flow fan<br />
direct drive model<br />
Swing-out type<br />
Airflow direction D (motor in outlet)<br />
Rugged sheet steel design.<br />
The impeller, motor and guide vane<br />
installation can be jointly swung out<br />
for inspection.<br />
Fan casing with drilled flanges as per<br />
DIN 24154 – Series 4.<br />
Max. operating temperature according<br />
to motor type<br />
(60° C with standard motor).<br />
<strong>Axial</strong> flow fan<br />
belt drive model<br />
Airflow direction D (outlet over bearing)<br />
The belt guard housing, doubling as<br />
motor support, is mounted on the<br />
casing. The impeller is supported in<br />
a maintenance-free double flange<br />
bearing having a rated service life of<br />
approx. 20,000 operating hrs.<br />
Max. operating temperature: 70° C.<br />
With outlet guide vanes.<br />
Fan casing with drilled flanges as per<br />
DIN 24154 – Series 3.<br />
<strong>Axial</strong> flow fan<br />
belt drive model<br />
Airflow direction D (outlet over bearing)<br />
Casing with tensioning device and<br />
belt guard on a common baseframe.<br />
The impeller is supported in antifriction<br />
bearings with grease valve and<br />
re-lubricating feature. Rated service<br />
life: approx. 50,000 operating hours.<br />
Max. operating temperature: 70° C.<br />
The belt tensioning installation with<br />
motor and belt drive are fitted in specially<br />
developed mountings. Outlet<br />
guide vanes enhance the fan output<br />
characteristics.<br />
Fan casing with drilled flanges as per<br />
DIN 24154 – Series 3.<br />
<strong>Axial</strong> flow fan - wall mounting type<br />
WAXO/WAXN series<br />
for installation into outside walls<br />
System consisting of:<br />
- axial fan direct drive model, impeller<br />
with shaft, casing with drilled flanges<br />
as per DIN 24154 series 3.<br />
Max. operating temperatures as per<br />
motor version. In case of normal<br />
motors: 60°C.<br />
- bellmouth with wire guard wall-mounting<br />
plate (drilled)<br />
- louvre damper<br />
AXIAL FLOW FANS<br />
TYPES - OVERVIEW<br />
M-A type<br />
R1 type<br />
R2 type<br />
005