<strong>HACCP</strong> PLAN<br />
PROCESS CATEGORY : THERMALLY PROCESSED COMMERCIALLY STERILE<br />
PRODUCT EXAMPLE : BEEF STEW<br />
PROCESS STEP<br />
THERMAL<br />
PROCESSING AND<br />
COOLING<br />
HAZARD<br />
DESCRIPTION<br />
BIOLOGICAL-B<br />
CHEMICAL-C<br />
PHYSICAL-P CCP<br />
B-Improper<br />
application of the<br />
thermal process may<br />
not provide sufficient<br />
lethality to achieve<br />
shelf stability, ensure<br />
commercial sterility,<br />
and prevent<br />
recontamination of<br />
product due to seam<br />
expansion.<br />
CRITICAL LIMITS<br />
5B As specified by<br />
processing authority, to<br />
ensure commercial<br />
sterility.<br />
MONITORING<br />
PROCEDURES/FREQUENCY/<br />
PERSON RESPONSIBLE<br />
Retort operator will monitor<br />
and record thermal processing<br />
conditions at intervals<br />
determined to be sufficient by<br />
the processing authority to<br />
ensure that the process schedule<br />
is properly applied including<br />
process application, venting<br />
procedures, and water<br />
chlorination. Retort operator<br />
will sign retort log and include<br />
date and time of action.<br />
CORRECTIVE/PREVENTIVE<br />
ACTION/PERSON<br />
RESPONSIBLE<br />
If a process deviation occurs, the<br />
plant designee will apply a filed<br />
alternate process schedule<br />
appropriate <strong>for</strong> the situation or<br />
hold the product pending a<br />
processing authority’s<br />
evaluation. Plant designee will<br />
document actions taken in retort<br />
log, venting, and/or cooling log,<br />
and retort temperature recorder<br />
charts, sign, date, and record<br />
time of corrective/preventive<br />
action.<br />
Notify plant designee.<br />
<strong>HACCP</strong> RECORDS<br />
Record all results,<br />
corrective, and<br />
preventive action(s)<br />
on daily retort log,<br />
venting, cooling,<br />
and temperature<br />
recorder charts/log<br />
and/or corrective/<br />
preventive action<br />
log. Sign, date, and<br />
record time of<br />
observation.<br />
VERIFICATION<br />
PROCEDURE/PERSON<br />
RESPONSIBLE<br />
An individual who did not<br />
produce the record(s) and<br />
who has successfully<br />
completed a course of<br />
instruction in <strong>HACCP</strong> or<br />
the responsible<br />
establishment official will<br />
review the log and charts<br />
within one working day<br />
after the thermal process.<br />
Quarterly calibration of<br />
retort.<br />
Audit to verify sampling<br />
techniques and accuracy<br />
of records; determine if<br />
the critical limit<br />
corresponds to the plant<br />
records; check to see if<br />
critical limit is adequate<br />
<strong>for</strong> hazard; assure<br />
corrective actions are<br />
adequate; document<br />
findings.