pyrotechnics.<br />
(4) Under no circumstances will personnel tamper with ammunition cartridges or<br />
(5) Blank <strong>and</strong> live ammunition will not be mixed.<br />
(6) Use of pyrotechnics <strong>and</strong> blank ammunition during the hours of darkness<br />
requires special coordination. Without prior scheduling <strong>and</strong> coordination, use of blank<br />
ammunition <strong>and</strong> pyrotechnics is forbidden in ROKA/US training areas, North of the Imjin River,<br />
<strong>and</strong> near the DMZ.<br />
(7) Any suspected or observed rounds-out of impact area requires the unit to<br />
“Cease Fire” <strong>and</strong> determine the cause. Rounds-out will be immediately reported to the RCC<br />
(See Appendix M).<br />
47. MALFUNCTIONING AMMUNITION.<br />
a. All malfunctions of ammunition will be reported immediately to the RCC (See<br />
Appendix N). The following are definitions of malfunctions:<br />
(1) UXO: Munitions that have failed to arm correctly or have failed to explode<br />
after being armed.<br />
(2) Cook-off: Ignition of the propellant of a chambered round initiated by the heat<br />
of the weapon.<br />
to function.<br />
(3) Hang-fire: Delay in the action of a primer, igniter, or propelling charge.<br />
(4) Misfires: Wholly or in part failure of primer or the propelling charge of a round<br />
b. When a live h<strong>and</strong> grenade fails to function, all operations on the range will cease.<br />
Personnel will withdraw from the firing points <strong>and</strong> the RCC will be notified. Personnel will not be<br />
allowed back in the area until the UXO grenade has been destroyed by <strong>Eighth</strong> <strong>Army</strong> EOD<br />
personnel.<br />
c. Do not disturb the weapon system, equipment, fragments, or residue at the<br />
malfunction site.<br />
48. CHEMICAL MUNITIONS.<br />
a. Excluding tear gas, no chemical munitions will be used in the ROK without the written<br />
permission of the <strong>Eighth</strong> <strong>Army</strong> Chemical Officer <strong>and</strong> approval from the servicing RCC. Units will<br />
submit a scenario, graphic overlay, <strong>and</strong> risk assessment to the RCC for approval.<br />
b. CS may be used only with approval from the servicing RCC. CS may not be used<br />
within 500 meters of any body of water (man-made or natural), civilian road, personnel,<br />
buildings, or livestock.<br />
26<br />
<strong>AK</strong> Pam <strong>350</strong>-<strong>20</strong>, 10 October <strong>20</strong>06