SECTION 3, continued<br />

Item Name Description<br />

1 ENTER<br />

Table 1 Operating Features and Functional Descriptions<br />

Used in Calibration Mode to select the value of the Formazin calibration standard and to initiate<br />

measurement of the standard. Pressing ENTER during measurement with Signal Averaging on<br />

clears the buffer of all previous data. Selects functions during instrument setup and Flow-Cell setup.<br />

Selects an edited sample number. Initiates zeroing in the Color Unit mode. Initiates zeroing<br />

measurement in the %T and Absorbance modes.<br />

2 Down Arrow Same as the up arrow except for direction of steps.<br />

3 Right Arrow<br />

4 Up Arrow<br />

5 SAMPLE<br />

6 Display Eight-digit LED display.<br />

7<br />

Mode Display<br />

(green 2-digit LED)<br />

8 Lamp<br />

9 CAL?<br />

10 RANGE<br />

Advances the cursor position during calibration standard editing, instrument setup and sample<br />

number selection. Also, used to ignore dilution water turbidity during calibration (if required).<br />

Edits LED digits in the calibration mode and steps through calibration standards 00 through 05<br />

(in the mode display). Edits the “SETUP” number (in the mode display) during the instrument setup<br />

procedure. Increments the sample number (in the mode display).<br />

Initiates editing of the sample number shown in the Mode display (green LED).<br />

Annunciator lights to indicate Sample mode is selected.<br />

Displays calibration standard number, setup parameter number or sample number.<br />

Pressing the up or down arrow key increments or decrements the sample number by one during<br />

measurement mode. The sample number is included on the time- and date-stamped measurement<br />

printout.(ThesamplenumberalsoiseditedbypressingtheSAMPLE key.)<br />

Lighted annunciator indicates when the instrument lamp is on.<br />

Flashes to indicate a low-level light condition.<br />

Lights to indicate the calibration information recorded during the calibration process is outside of the<br />

acceptable range (may be an operator calibration error or an instrument malfunction).<br />

The instrument must be recalibrated if the CAL? annunciator flashes.<br />

Selects Auto Ranging or Manual Ranging.<br />

Pressing RANGE steps the instrument through the range options.<br />

11 Manual Range Lighted annunciator indicates when the instrument is in the manual ranging mode.<br />

12 Auto Range Lighted annunciator indicates when the instrument is in the automatic ranging mode.<br />

13 UNITS Exit<br />

14 RATIO<br />

15 FLOW<br />

16 PRINT<br />

Selects unit of measure. Available options are NTU, EBC, NEPH, %T, Absorbance, CU and two ASC<br />

(Application Specific) units. Also, exits calibration or setup without saving new values.<br />

Turns ratioing on or off [only in NTU, EBC, NEPHLO, or ASC modes with