APPENDIX WIRELESS PHYSICAL COLLOCATION/AT&T-13STATE<br />
PAGE 41 OF 62<br />
AT&T-13STATE/NEW CINGULAR WIRLESS <strong>PCS</strong>, LLC<br />
020106<br />
17.6.4 AT&T-13STATE must advise Wireless Collocator if extraordinary costs will be incurred within<br />
twenty (20) business days of the Wireless Collocator’s request for space.<br />
17.6.5 Extraordinary costs will only be billed upon receipt of the signed acceptance and construction will<br />
not begin until receipt of the Wireless Collocator’s signed acceptance and payment.<br />
18. RATE REGULATIONS (AT&T-13STATE DOES ALL WORK)<br />
18.1 The Wireless Collocator may elect to have AT&T-13STATE provision the collocation site or the Wireless<br />
Collocator may elect to hire an AT&T-13STATE Approved Tier 1 Vendor to provision the collocation site<br />
per Section 21, CDOW (Collocator Does Own Work).<br />
18.2 Rate Elements<br />
All rates and charges for the following rate elements can be found in the Collocation Rate Summary.<br />
18.2.1 Planning Fees<br />
18.2.1.1 The Planning Fee, as specified in AT&T-13STATE’s Interconnector's Collocation Services<br />
Handbook for Physical Collocation in AT&T-13STATE, recovers AT&T-13STATE’s costs<br />
incurred to estimate the quotation of charges, project management costs, engineering<br />
costs, and other related planning activities for the Wireless Collocator’s request for the<br />
Physical Collocation arrangements. The initial Planning Fee will apply to the Wireless<br />
Collocator’s Physical Collocation request. In addition, a non-standard Planning Fee will<br />
apply when a request includes DC power requirements other than 2-10, 2-20, 2-30, 2-40,<br />
2-50, or 2-100 Amp power feeds for Caged, Cageless, or Caged Common Collocation, or<br />
2-100, 2-200, 2-300, or 2-400 Amp power feeds for Adjacent On-Site Collocation, or other<br />
than integrated ground plane, or when floor space requirements are greater than four<br />
hundred (400) square feet. Requests for additions to the initial request, such as the<br />
addition of Wireless Collocator provided equipment that requires AT&T-13STATE to<br />
engineer and purchase additional equipment will result in a Subsequent Planning Fee. A<br />
major revision to the initial request for Physical Collocation that changes floor space<br />
requirements, cable entrance facilities requirements, or changes DC Power Distribution<br />
will be considered a total revision and result in the reapplication of an initial Planning Fee.<br />
Rates and charges are as found in the Collocation Rate Summary.<br />
18.2.2 Billing for Caged Shared and Caged Common Collocation Arrangements<br />
18.2.2.1 Except for certain charges identified as related to Caged Shared Collocation, each<br />
Wireless Collocator shall be billed separately and shall be able to order and provision<br />
separately. In the case of Caged Shared Collocation, AT&T-13STATE shall bill the<br />
original Wireless Collocator for space. Wireless Collocators located in a Caged Common<br />
Collocation area shall have direct billing arrangements with AT&T-13STATE for floor<br />
space and all other applicable interconnection arrangements.<br />
18.2.3 Floor Space Charges<br />
18.2.3.1 Caged Collocation<br />
18.2.3.1.1 The Caged Collocation option provides the Wireless Collocator with an<br />
individual enclosure (not including a top). This enclosure is an area<br />
designated by AT&T-13STATE within an Eligible Structure to be used by the<br />
Wireless Collocator for the sole purpose of installing, maintaining and<br />
operating the Wireless Collocator-provided equipment.<br />
18.2.3.1.2 AT&T-13STATE will provide Floor Space, floor space site conditioning, Cage<br />
Common Systems Materials, Cage Preparation and Safety and Security<br />
charges in increments of one (1) square foot. For this reason, Wireless<br />
Collocator will be able to order space and a cage enclosure in amounts as<br />
small as that sufficient to house and maintain a single rack or bay of