42<br />

<strong>Smoke</strong>, <strong>Fire</strong> <strong>and</strong> <strong>Fumes</strong> <strong>in</strong> <strong>Transport</strong> <strong>Aircraft</strong><br />

(AIRCRAFT TYPE X — Series A/B — CF6 Eng<strong>in</strong>es)<br />

SMOKE IN CABIN AND/OR FLIGHT DECK<br />

20. IF AIR CONDITIONING SMOKE IS SUSPECTED<br />

21. APU bleed switch . . . . . . . . . . . . . . . . . . OFF<br />

22. Blower switch . . . . . . . . . . . . . . . . . . . . AUTO<br />

23. Extract switch . . . . . . . . . . . . . . . . . . . . AUTO<br />

24. Pack 1 switch . . . . . . . . . . . . . . . . . . . . . OFF<br />

25. Does smoke decrease? . . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />

25.1 NO . . . . GO TO 26<br />

26. Pack 1 switch . . . . . . . . . . . . . . . . . . . . . . ON<br />

27. Pack 2 switch . . . . . . . . . . . . . . . . . . . . . OFF<br />

28. Cargo heat aft isolation valve switch. . . OFF<br />

29. Does smoke decrease?. . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />

29.1 NO . . . . GO TO 30<br />

30. If smoke persists Pack 2 switch . . . . . . . ON<br />

31. Blower switch . . . . . . . . . . . . . . . . . . . . . OVERRIDE<br />

32. Extract switch . . . . . . . . . . . . . . . . . . . . . OVERRIDE<br />

END OF AIR CONDITIONING SMOKE DRILL > CONTINUE WITH STEP 33<br />

33. Does smoke decrease?. . . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />

33.1 NO . . . . GO TO 50<br />

34. IF ELECTRICAL OR AVIONICS SMOKE IS SUSPECTED<br />

35. Shed AC BUS 1 as follows<br />

35.1 GEN 2 . . . . . . . . . . . . . . . . . . . . . . . . . . CHECK ON<br />

35.2 ELEC page . . . . . . . . . . . . . . . . . . . . . . SELECT<br />

35.3 BUS Tie . . . . . . . . . . . . . . . . . . . . . . . . OFF<br />

35.4 AC ESS FEED . . . . . . . . . . . . . . . . . . . . ALTN<br />

35.5 GEN 1 . . . . . . . . . . . . . . . . . . . . . . . . . . OFF<br />

35.6 <strong>Smoke</strong> dissipation . . . . . . . . . . . . . . . . CHECK<br />

36. Does smoke decrease? . . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />

36.1 NO . . . . GO TO 37<br />

37. GEN 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . ON<br />

38. AC ESS FEED . . . . . . . . . . . . . . . . . . . . . . NORM<br />

39. Shed AC BUS 2 as follows<br />

39.1 GEN 1 . . . . . . . . . . . . . . . . . . . . . . . . . . CHECK ON<br />

39.2 ELEC page . . . . . . . . . . . . . . . . . . . . . . SELECT<br />

39.3 AC ESS FEED . . . . . . . . . . . . . . . . . . . . ALTN<br />

39.4 BUS TIE . . . . . . . . . . . . . . . . . . . . . . . . . OFF<br />

39.5 GEN 2 . . . . . . . . . . . . . . . . . . . . . . . . . . OFF<br />

39.6 <strong>Smoke</strong> dissipation . . . . . . . . . . . . . . . . CHECK<br />

40. Does smoke decrease? . . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />

40.1 NO . . . . GO TO 41<br />

DRILL CONTINUES ON NEXT PAGE