Smoke, Fire and Fumes in Transport Aircraft - Royal Aeronautical ...
Smoke, Fire and Fumes in Transport Aircraft - Royal Aeronautical ...
Smoke, Fire and Fumes in Transport Aircraft - Royal Aeronautical ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
42<br />
<strong>Smoke</strong>, <strong>Fire</strong> <strong>and</strong> <strong>Fumes</strong> <strong>in</strong> <strong>Transport</strong> <strong>Aircraft</strong><br />
(AIRCRAFT TYPE X — Series A/B — CF6 Eng<strong>in</strong>es)<br />
SMOKE IN CABIN AND/OR FLIGHT DECK<br />
20. IF AIR CONDITIONING SMOKE IS SUSPECTED<br />
21. APU bleed switch . . . . . . . . . . . . . . . . . . OFF<br />
22. Blower switch . . . . . . . . . . . . . . . . . . . . AUTO<br />
23. Extract switch . . . . . . . . . . . . . . . . . . . . AUTO<br />
24. Pack 1 switch . . . . . . . . . . . . . . . . . . . . . OFF<br />
25. Does smoke decrease? . . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />
25.1 NO . . . . GO TO 26<br />
26. Pack 1 switch . . . . . . . . . . . . . . . . . . . . . . ON<br />
27. Pack 2 switch . . . . . . . . . . . . . . . . . . . . . OFF<br />
28. Cargo heat aft isolation valve switch. . . OFF<br />
29. Does smoke decrease?. . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />
29.1 NO . . . . GO TO 30<br />
30. If smoke persists Pack 2 switch . . . . . . . ON<br />
31. Blower switch . . . . . . . . . . . . . . . . . . . . . OVERRIDE<br />
32. Extract switch . . . . . . . . . . . . . . . . . . . . . OVERRIDE<br />
END OF AIR CONDITIONING SMOKE DRILL > CONTINUE WITH STEP 33<br />
33. Does smoke decrease?. . . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />
33.1 NO . . . . GO TO 50<br />
34. IF ELECTRICAL OR AVIONICS SMOKE IS SUSPECTED<br />
35. Shed AC BUS 1 as follows<br />
35.1 GEN 2 . . . . . . . . . . . . . . . . . . . . . . . . . . CHECK ON<br />
35.2 ELEC page . . . . . . . . . . . . . . . . . . . . . . SELECT<br />
35.3 BUS Tie . . . . . . . . . . . . . . . . . . . . . . . . OFF<br />
35.4 AC ESS FEED . . . . . . . . . . . . . . . . . . . . ALTN<br />
35.5 GEN 1 . . . . . . . . . . . . . . . . . . . . . . . . . . OFF<br />
35.6 <strong>Smoke</strong> dissipation . . . . . . . . . . . . . . . . CHECK<br />
36. Does smoke decrease? . . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />
36.1 NO . . . . GO TO 37<br />
37. GEN 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . ON<br />
38. AC ESS FEED . . . . . . . . . . . . . . . . . . . . . . NORM<br />
39. Shed AC BUS 2 as follows<br />
39.1 GEN 1 . . . . . . . . . . . . . . . . . . . . . . . . . . CHECK ON<br />
39.2 ELEC page . . . . . . . . . . . . . . . . . . . . . . SELECT<br />
39.3 AC ESS FEED . . . . . . . . . . . . . . . . . . . . ALTN<br />
39.4 BUS TIE . . . . . . . . . . . . . . . . . . . . . . . . . OFF<br />
39.5 GEN 2 . . . . . . . . . . . . . . . . . . . . . . . . . . OFF<br />
39.6 <strong>Smoke</strong> dissipation . . . . . . . . . . . . . . . . CHECK<br />
40. Does smoke decrease? . . . . . . . . . . . . . YES . . . END > (or LAND > use NORMAL C/L)<br />
40.1 NO . . . . GO TO 41<br />
DRILL CONTINUES ON NEXT PAGE