3. CZ-P160BK1U<br />
Use: For indoor unit (Capacity after distribution joint is 76,400 BTU/h (22.4 kW) or less.)<br />
Example:<br />
A<br />
Insulation<br />
4-21/64<br />
3-13/16<br />
Gas tubing Liquid tubing<br />
B<br />
Distr ib utio n<br />
Joint B<br />
B<br />
C<br />
A<br />
D<br />
Insulation<br />
C<br />
6-57/64<br />
5-5/16<br />
2 - 5 3 / 6 4<br />
13<br />
4-21/64<br />
3-13/16<br />
C<br />
Distr ib utio n<br />
Joint<br />
C<br />
Table 1-15 Size of connection point on each part (Shown are inside diameters of tubing)<br />
Size Part A Part B Part C Part D Part E<br />
in. (mm)<br />
Example:<br />
D C B<br />
Distr ib ution<br />
Joint<br />
Insulation<br />
A<br />
Gas tubing Liquid tubing<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
6-57/64<br />
5-5/16<br />
A<br />
B C D<br />
Reducing<br />
Joints<br />
E F<br />
4 - 3 1 / 6 4<br />
G F<br />
Distr ib ution<br />
Joint<br />
Insulation<br />
E<br />
4-21/64<br />
3-13/16<br />
Size Part A Part B Part C Part D Part E Part F Part G Part H<br />
in. (mm)<br />
Example:<br />
D<br />
(A)<br />
C<br />
Insulation<br />
ø3/4" ø5/8" ø1/2" ø3/8" ø1/4"<br />
(ø19.05) (ø15.88) (ø12.7) (ø9.52) (ø6.35)<br />
B<br />
Distr ib ution<br />
Joint<br />
Gas tubing Liquid tubing<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
B<br />
B<br />
(A)<br />
C D<br />
(A)<br />
Reducing<br />
Joints<br />
4 - 3 1 / 6 4<br />
( ): Outside dimension<br />
F<br />
Distr ib ution<br />
Joint<br />
Insulation<br />
G<br />
E<br />
F<br />
G<br />
H<br />
4-21/64<br />
3-13/16<br />
G<br />
H<br />
I<br />
J<br />
C DE<br />
ø1-1/8" ø1" ø7/8" ø3/4" ø5/8" ø1/2" ø3/8" ø1/4"<br />
(ø28.58) (ø25.4) (ø22.22) (ø19.05) (ø15.88) (ø12.7) (ø9.52) (ø6.35)<br />
D<br />
E<br />
E<br />
G<br />
F G H<br />
Reducing<br />
Joints<br />
F<br />
H<br />
Unit: in.<br />
4. CZ-P680BK1U<br />
Use: For indoor unit (Capacity after distribution joint is greater than 76,400 BTU/h (22.4 kW) and no more than 232,000 BTU/h (68.0 kW).)<br />
Table 1-16 Size of connection point on each part (Shown are inside diameters of tubing)<br />
Unit: in.<br />
5. CZ-P1350BK1U<br />
Use: For indoor unit (Capacity after distribution joint is greater than 232,000 BTU/h (68.0 kW) and no more than 460,700 BTU/h (135.0 kW).)<br />
Table 1-17 Size of connection point on each part (Shown are inside diameters of tubing)<br />
Reducing<br />
Joints<br />
2 - 5 3 / 6 4<br />
2 - 5 3 / 6 4<br />
2 - 5 3 / 6 4<br />
Unit: in.<br />
Size Part A Part B Part C Part D Part E Part F Part G Part H Part I Part J<br />
in. (mm)<br />
ø1-3/8"<br />
(ø34.92)<br />
ø1-1/4"<br />
(ø31.75)<br />
ø1-1/8"<br />
(ø28.58)<br />
ø1"<br />
(ø25.4)<br />
ø7/8"<br />
(ø22.22)<br />
ø3/4"<br />
(ø19.05)<br />
ø5/8"<br />
(ø15.88)<br />
ø1/2"<br />
(ø12.7)<br />
ø3/8"<br />
(ø9.52)<br />
ø1/4"<br />