3. CZ-P160BK1U<br />

Use: For indoor unit (Capacity after distribution joint is 76,400 BTU/h (22.4 kW) or less.)<br />

Example:<br />

A<br />

Insulation<br />

4-21/64<br />

3-13/16<br />

Gas tubing Liquid tubing<br />

B<br />

Distr ib utio n<br />

Joint B<br />

B<br />

C<br />

A<br />

D<br />

Insulation<br />

C<br />

6-57/64<br />

5-5/16<br />

2 - 5 3 / 6 4<br />

13<br />

4-21/64<br />

3-13/16<br />

C<br />

Distr ib utio n<br />

Joint<br />

C<br />

Table 1-15 Size of connection point on each part (Shown are inside diameters of tubing)<br />

Size Part A Part B Part C Part D Part E<br />

in. (mm)<br />

Example:<br />

D C B<br />

Distr ib ution<br />

Joint<br />

Insulation<br />

A<br />

Gas tubing Liquid tubing<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

6-57/64<br />

5-5/16<br />

A<br />

B C D<br />

Reducing<br />

Joints<br />

E F<br />

4 - 3 1 / 6 4<br />

G F<br />

Distr ib ution<br />

Joint<br />

Insulation<br />

E<br />

4-21/64<br />

3-13/16<br />

Size Part A Part B Part C Part D Part E Part F Part G Part H<br />

in. (mm)<br />

Example:<br />

D<br />

(A)<br />

C<br />

Insulation<br />

ø3/4" ø5/8" ø1/2" ø3/8" ø1/4"<br />

(ø19.05) (ø15.88) (ø12.7) (ø9.52) (ø6.35)<br />

B<br />

Distr ib ution<br />

Joint<br />

Gas tubing Liquid tubing<br />

C<br />

D<br />

E<br />

F<br />

G<br />

H<br />

B<br />

B<br />

(A)<br />

C D<br />

(A)<br />

Reducing<br />

Joints<br />

4 - 3 1 / 6 4<br />

( ): Outside dimension<br />

F<br />

Distr ib ution<br />

Joint<br />

Insulation<br />

G<br />

E<br />

F<br />

G<br />

H<br />

4-21/64<br />

3-13/16<br />

G<br />

H<br />

I<br />

J<br />

C DE<br />

ø1-1/8" ø1" ø7/8" ø3/4" ø5/8" ø1/2" ø3/8" ø1/4"<br />

(ø28.58) (ø25.4) (ø22.22) (ø19.05) (ø15.88) (ø12.7) (ø9.52) (ø6.35)<br />

D<br />

E<br />

E<br />

G<br />

F G H<br />

Reducing<br />

Joints<br />

F<br />

H<br />

Unit: in.<br />

4. CZ-P680BK1U<br />

Use: For indoor unit (Capacity after distribution joint is greater than 76,400 BTU/h (22.4 kW) and no more than 232,000 BTU/h (68.0 kW).)<br />

Table 1-16 Size of connection point on each part (Shown are inside diameters of tubing)<br />

Unit: in.<br />

5. CZ-P1350BK1U<br />

Use: For indoor unit (Capacity after distribution joint is greater than 232,000 BTU/h (68.0 kW) and no more than 460,700 BTU/h (135.0 kW).)<br />

Table 1-17 Size of connection point on each part (Shown are inside diameters of tubing)<br />

Reducing<br />

Joints<br />

2 - 5 3 / 6 4<br />

2 - 5 3 / 6 4<br />

2 - 5 3 / 6 4<br />

Unit: in.<br />

Size Part A Part B Part C Part D Part E Part F Part G Part H Part I Part J<br />

in. (mm)<br />

ø1-3/8"<br />

(ø34.92)<br />

ø1-1/4"<br />

(ø31.75)<br />

ø1-1/8"<br />

(ø28.58)<br />

ø1"<br />

(ø25.4)<br />

ø7/8"<br />

(ø22.22)<br />

ø3/4"<br />

(ø19.05)<br />

ø5/8"<br />

(ø15.88)<br />

ø1/2"<br />

(ø12.7)<br />

ø3/8"<br />

(ø9.52)<br />

ø1/4"<br />

(ø6.35)