Section 1<br />

PCI-Based I/O Hardware<br />

This section covers the configuration of the Peripheral Component Interconnect<br />

(PCI)-based hardware, I/O processors, host bus adapters (HBAs), and network<br />

interface cards (NICs). It is intended to help the service representative set up and<br />

maintain the I/O hardware complex.<br />

Note: The <strong>Dorado</strong> <strong>400</strong>, <strong>400</strong>0, and <strong>4100</strong> Series only support the SIOP PCI-based I/O<br />

hardware.<br />

Documentation Updates<br />

This document contains all the information that was available at the time of<br />

publication. Changes identified after release of this document are included in problem<br />

list entry (PLE) 18850290. To obtain a copy of the PLE, contact your Unisys<br />

representative or access the current PLE from the Unisys Product Support Web site:<br />

http://www.support.unisys.com/all/ple/18850290<br />

Note: If you are not logged into the Product Support site, you will be asked to do<br />

so.<br />

1.1. Architecture Overview<br />

With the introduction of the <strong>Dorado</strong> <strong>300</strong> Series, the architecture of the <strong>Dorado</strong><br />

systems was revolutionized. The <strong>Dorado</strong> <strong>400</strong>, <strong>400</strong>0, and <strong>4100</strong> Series systems move<br />

that revolution forward.<br />

1.1.1. <strong>Dorado</strong> <strong>300</strong> Series<br />

The <strong>Dorado</strong> <strong>300</strong> Series systems contain cell pairs. One cell contains the instruction<br />

processors (IPs) and is attached to another cell for input/output (I/O).<br />

The minimum configuration contains the following:<br />

• One IP cell with 4 OS 2200 IPs and 4 GB of memory<br />

• One I/O cell<br />

For systems with more than one IP cell, the cells are arranged so that the IP cells are<br />

adjacent. For example, IP cell 0 is adjacent to IP cell 1. I/O cell 0 is below the two IP<br />

cells and I/O cell 1 is above the two IP cells.<br />

3839 6586–009 1–1