Catalog LV1 T 2009 Chapter 3 EN
Catalog LV1 T 2009 Chapter 3 EN
Catalog LV1 T 2009 Chapter 3 EN
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
3<br />
Controls — Contactors and Contactor Assemblies<br />
Project planning aids<br />
Position of the terminals for 3RT1 contactors and accessories (valid for screw and Cage Clamp terminals)<br />
Sizes S6 to S12<br />
3RT1 .5, 3RT1 .6, 3RT1 .7 contactors<br />
With conventional operating<br />
mechanism<br />
(3RT1. ..-.A...)<br />
With laterally mountable auxiliary<br />
switch blocks<br />
3RH19 21-1DA11<br />
(for 2 NO + 2 NC, included in the<br />
contactors)<br />
3RH19 21-1JA11<br />
(can be extended to 4 NO +<br />
4 NC)<br />
3/228<br />
Siemens LV 1 T · <strong>2009</strong><br />
With solid-state operating<br />
mechanism<br />
(3RT1. ..-.N...)<br />
With laterally mountable auxiliary<br />
switch blocks<br />
3RH19 21-1DA11<br />
(for 2 NO + 2 NC, included in the<br />
contactors)<br />
3RH19 21-1JA11<br />
(can be extended to 4 NO +<br />
4 NC)<br />
With solid-state operating<br />
mechanism<br />
(3RT1. ..-.P...)<br />
With laterally mountable auxiliary<br />
switch blocks<br />
3RH19 21-1DA11<br />
(for 1 NO + 1 NC, included in the<br />
contactors)<br />
3RH19 21-1JA11<br />
(can be extended to 2 NO +<br />
2 NC)<br />
With solid-state operating<br />
mechanism<br />
(3RT1. ..-.Q...)<br />
With laterally mountable auxiliary<br />
switch blocks<br />
3RH19 21-1DA11<br />
(for 1 NO + 1 NC, included in the<br />
contactors)<br />
3RH19 21-1JA11<br />
(can be extended to 2 NO +<br />
2 NC)<br />
2 NO + 2 NC or 4 NO + 4 NC 2 NO + 2 NC or 4 NO + 4 NC 1 NO + 1 NC or 2 NO + 2 NC 1 NO + 1 NC or 2 NO + 2 NC<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Contactors with 4 main contacts, size S00<br />
Terminal designations according to <strong>EN</strong> 50005<br />
Contactors with 4 main contacts, sizes S0 to S3<br />
Terminal designations according to <strong>EN</strong> 50005<br />
3RT13 and 3RT15 contactors 3RT13 and 3RT15 contactors<br />
4 NO 2 NO + 2 NC 4 NO 2 NO + 2 NC<br />
<br />
<br />
Accessories for size S00 contactors and contactor relays<br />
Terminal designations according to <strong>EN</strong> 50005<br />
3RH19 11-.F. . . auxiliary switch blocks and 3RH19 11-.NF. . solid-state compatible auxiliary switch blocks<br />
for snapping onto the front<br />
2 NO<br />
Ident. No.: 20<br />
53 63<br />
54 64 NSB00579<br />
4 NO<br />
Ident. No.: 40<br />
53 63 73 83<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
1 NO + 1 NC<br />
11<br />
53 61<br />
3 NO + 1 NC<br />
31<br />
SPS<br />
DC 24 V<br />
61 21<br />
53 13<br />
54 14<br />
62 22<br />
54 62 NSB00580<br />
53 61 73 83<br />
<br />
<br />
54 64 74 84 NSB00583<br />
54 62 NSB00584<br />
A1 A2<br />
1 L1 3 L2 5 L3<br />
2 T1 4 T2 6 T3<br />
<br />
<br />
<br />
© Siemens AG <strong>2009</strong><br />
2 NC<br />
02<br />
NSB0_01154a<br />
31 71<br />
43 83<br />
44 84<br />
32 72<br />
51 61<br />
52 62 NSB00581<br />
2 NO + 2 NC<br />
22<br />
53 61 71 83<br />
74 84 54 84 NSB00585<br />
<br />
<br />
<br />
<br />
<br />
)<br />
)<br />
<br />
!<br />
"<br />
<br />
)<br />
#<br />
$<br />
)<br />
%<br />
&<br />
5 * # % % =<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
1 NO + 1 NC<br />
11 U<br />
57 65<br />
58 66 NSB00582<br />
with make-before-break<br />
2 NO + 2 NC<br />
22 U<br />
57 67 75 85<br />
62 72 58 86 NSB00586<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
A1 A2<br />
1 R1 R3 3<br />
2 R2 R4 4<br />
A1 A2<br />
2 NO + 2 NC<br />
11/11 U<br />
53 61 75 87<br />
68 76 54 88 NSB00587<br />
62 76<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
with make-before-break 1 NO + 1 NC ON-delay<br />
1 NO + 1 NC with makebefore-break<br />
NSB00578