© Siemens AG <strong>2009</strong><br />
3RT, 3TB, 3TF Contactors for Switching Motors<br />
Contactors Type 3TF28<br />
3TF29<br />
3TF2 contactors, 3-pole, 2.2 ... 4 kW<br />
3TF20 . .-0. . .,<br />
3TF22 . .-0. . .<br />
3TF20 ..-3...,<br />
3TF20 ..-6...,<br />
3TF20 ..-7...<br />
Size S00 S00 S00<br />
Main circuit<br />
AC capacity<br />
Utilization category AC-5a<br />
Switching gas discharge lamps<br />
Per main current path at 230/220 V<br />
Rated power Rated operational current<br />
per lamp<br />
- Uncorrected<br />
per lamp (A)<br />
L18W 0.37 Units43 L36W 0.43 Units37 L58W<br />
- DUO switching<br />
0.67 Units23 L18W 011 Units144 L36W 0.21 Units76 L58W 0.32 Units50 Switching gas discharge lamps with correction, solid-state ballast<br />
Per main current path at 230/220 V<br />
Rated power<br />
Capacitance Rated operational current<br />
per lamp<br />
- Parallel correction<br />
(μF)<br />
per lamp (A)<br />
L18W 4.5 0.11 Units22 L36W 4.5 0.21 Units22 L58W<br />
- With solid-state ballast (single<br />
lamp)<br />
7 0.31 Units14 L18W 6.8 0.10 Units63 L36W 6.8 0.18 Units35 L58W<br />
- With solid-state ballast (two<br />
lamps)<br />
10 0.27 Units23 L18W 10 0.18 Units35 L36W 10 0.35 Units18 L58W 22 0.52 Units12 Utilization category AC-5b,<br />
switching incandescent lamps<br />
Per main current path at 230/220 V<br />
kW 1.6 --<br />
Utilization category AC-6a,<br />
switching AC transformers<br />
Rated operational current Ie - For inrush current n = 20 At 400 V A 2.9 5.1 5.1<br />
- For inrush current n = 30<br />
Rated power P<br />
At 400 V A 1.9 3.3 3.3<br />
- For inrush current n = 20 Up to 230/220 V kVA 1.14 2.0 2.0<br />
400/380 V kVA 2 3.5 3.5<br />
500 V kVA 4.1 4.6 4.6<br />
690/660 V kVA 5.4 6.0 --<br />
- For inrush current n = 30 Up to 230/220 V kVA 0.74 1.3 1.3<br />
400/380 V kVA 1.3 2.3 2.3<br />
500 V kVA 2.8 3.1 3.1<br />
690/660 V kVA 3.6 4.0 --<br />
For deviating inrush current factors x, the power must be recalculated as follows:<br />
Px = Pn30 x(30/x)<br />
Utilization category AC-6b<br />
Switching low-inductance (low-loss, metallized dielectric) AC capacitors<br />
Utilization category AC-7a<br />
Switching low inductive loads in household appliances<br />
No switching capacity<br />
Rated operational current Ie (at 55 °C) At 400/380 V<br />
690/660 V<br />
A<br />
A<br />
16<br />
16<br />
16<br />
16<br />
16<br />
--<br />
Rated power at 50 and 60 Hz At 230/220 V kW 6 6 6<br />
400/380 V kW 10 10 10<br />
Minimum conductor cross-section for loads with Ie mm 2<br />
Utilization category AC-7b<br />
Switching motor loads in household appliances<br />
2.5 2.5 2.5<br />
Rated operational current Ie Up to 220 V<br />
230 V<br />
A<br />
A<br />
5.1<br />
5.1<br />
9.0<br />
9.0<br />
9.0<br />
9.0<br />
380 V A 5.1 9.0 9.0<br />
400 V A 5.1 8.4 8.4<br />
Rated power of motors At 110 V kW 0.68 1.2 1.2<br />
at 50 and 60 Hz and 220 V kW 1.3 2.4 2.4<br />
230 V kW 1.4 2.5 2.5<br />
240 V kW 1.5 2.6 2.6<br />
380 V kW 2.2 4.0 4.0<br />
400 V kW 2.4 4.0 4.0<br />