24.08.2013 Views

SAE J1939 - esd electronics, Inc.

SAE J1939 - esd electronics, Inc.

SAE J1939 - esd electronics, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Parameter Group<br />

Name<br />

Parameter Group<br />

Number<br />

<strong>SAE</strong> <strong>J1939</strong> – Transport Protocol<br />

Transport Protocol – Data Transfer (TP.DT)<br />

60160 (00EB00hex)<br />

Definition Data Transfer of Multi-Packet Messages<br />

Transmission Rate According to the Parameter Group Number to be transferred<br />

Data Length 8 bytes<br />

Extended Data Page (R) 0<br />

Data Page 0<br />

PDU Format 235<br />

PDU Specific Destination Address<br />

Default Priority 7<br />

Data Description<br />

Byte 1 – Sequence Number (1 to 255)<br />

2-8 - Data<br />

© <strong>esd</strong> <strong>electronics</strong>, <strong>Inc</strong>. • 525 Bernardston Road • Greenfield, MA 01301 Page 32