8 4 WESTERN ELECTRIC COMPANY<br />

Nos . 1101 and 1102 Switchboards-Continued<br />

Dimensions of No . 1102 cabinet<br />

5 ft . in . high ; 2 ft . in . long ; 2 ft . 3<br />

No . 1101-Front No . 1101-Rear in. deep.<br />

No . 105 SWITCHBOARD<br />

ing circuit is arranged with a key to<br />

throw in the hand generator or some<br />

other source of ringing current . Cable<br />

for the equipment ordered is provided<br />

sufficient to extend fifteen feet from<br />

the base of the section .<br />

In ordering specify the number of<br />

circuits to be equippad in each section,<br />

the type of the transmitter, and<br />

whether two or four party selective<br />

ringing is tobe provided .<br />

1 e s s repeating<br />

coils . . . . . . . . . . . . . . . $ 436 .97 $ 664.23<br />

Dimensions of No . 1101 cabinet<br />

5 ft . 14 in . high ; 2 ft . in . long ; .2 ft .<br />

3 in . deep.<br />

The face ofthe cabinet is made ofmahogany and the unexposed parts of a lighterwood with a mahogany<br />

finish . Two or more may be lined up without any change in the woodwork. The trunk circuits are of<br />

the call wire type and are arranged for connections between sections .<br />

Provision is therefore made for in<strong>com</strong>ing trunks at each section, which<br />

will be connected to outgoing trunks at all the other sections . Wiring is<br />

always provided for the repeating coils but unless otherwise specified<br />

the circuits with which these may be used are equipped the same as<br />

those without the coils . All cord circuits are arranged for ringing on the<br />

answering and calling cords . A suspended type of transmitter (No . 232-W)<br />

is provided unless the chest type (No . 234-W) is specified . A head receiver<br />

is always furnished . A night alarm bell is supplied, together with a key<br />

to cut it out of service . A five-bar hand generator is mounted in each<br />

section. Two or four party selective ringing may be provided . A generator<br />

switching circuit is arranged with a key to throw in the hand<br />

generator or some other source of ringing current . No cable is provided<br />

unless ordered . In ordering specify the number of circuits to be equipped<br />

in each section, the type of transmitter and whether two or four party<br />

selective ringing is to be provided .<br />

. . . .<br />

.<br />

. .<br />

.<br />

Capacity<br />

No. 105<br />

Section<br />

Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

Toll lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

Subscriber lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ., . .<br />

In<strong>com</strong>ing trunk lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

Outgoing trunk lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

Call wire circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

Cord circuits with repeating coil . . . . . . . . . . . . . . . . . . . . . . . . . .<br />

Cord circuits without repeating coil . . . . . . . . . . . . . . . . . . . . . .<br />

List price of one section fully equipped less repeating coils . . .<br />

1<br />

15<br />

150<br />

12<br />

45<br />

5<br />

5<br />

7<br />

$506.14<br />

Dimensions of cabinet, 5 ft . in . high ; 2 ft . 1 in . long ; 2 ft .<br />

No . 1C5 1 is in . deep .<br />

WRITE FOR LIBERAL DISCOUNTS<br />

No . 1101- No. 1102<br />

Capacity Section Section<br />

Operator's position 1 1<br />

Line circuits 100 160<br />

Trunk circuits 10 20<br />

Cord circuits with repeating<br />

coil 3 5<br />

Cord circuits without<br />

repeating coil 7 10<br />

List price of one sec-<br />

tion fully equipped