7 6 WESTERN ELECTRIC COMPANY<br />

No. 9 SWITCHBOARD<br />

No . 2 Chief Operator's Desk<br />

DESKS<br />

The necessary desks, such as Wire Chief's,<br />

Chief Operator's, \tanager's and Information<br />

Desks, will be provided with the multiple<br />

switchboard .<br />

POWER PLANT<br />

The power plant is laid out on the basis of<br />

24 volt battery supply for local connections<br />

No . 9 Wire Chief's Desk and 48 volt supply for toll and long distance<br />

connections . For charging the storage batteries,<br />

it is considered desirable to have duplicate<br />

sources of power and the usual arrangement is to have two charging sets entirelyindependent of each other,<br />

one to operate from the city power supply and the other run from a gas engine installed at the exchange,<br />

the latter is to be used as an emergency set in case of accidents, or abreakdown in the city plant .<br />

To provide ringing current, duplicate ringing machines are ordinarily furnished, one run from the<br />

storage battery and the other from the city power supply . These sets may be equipped with<br />

interrupters for tone, trouble and busy test service .<br />

The No . 9 switchboard is used in offices up to 800 lines capacity . Two types of this board are furnished,<br />

one for use in offices to handle only local and toll traffic and theother in offices such as those in the vicinity<br />

of large telephone centers, where calls will be trunked to other exchanges . These are known as the No . 9-D<br />

and No . 9-C switchboards respectively, and differ principally in that the No . 9-D is arranged for 24 and<br />

the No. 9-C for 38 volt battery supply .<br />

These switchboards are furnished with magnetic line and supervisory signals, and are arranged for<br />

negative supervision .<br />

The cord circuits on the subscriber section are equipped with condensers, and those on the toll sections<br />

with repeating coils . The toll cord circuits are universal, i.e ., they are entirely automatic, being arranged<br />

so that either toll to toll or toll to local connections can be made without anyadditional work by the operator,<br />

no keys or switching devices, other than the regular listening and ringing keys, being necessary .<br />

The board is self-contained, terminal strips and connecting rack being mounted on the rear to provide<br />

for cross-connecting the multiple jacks and line signals .<br />

This section is a two-panel single operator's section with a capacity for 400 multiple jacks and 200 line<br />

signals . The lines are n:ultipled every second section, making a total multiple capacity of 800 lines .<br />