No . 37-A<br />

No . 39-A<br />

No . 25-A<br />

No . 25-C<br />

No . 26-A<br />

WESTERN ELECTRIC COMPANY<br />

Repeating Coils-Continued<br />

Resistance Size of Base List Price<br />

Code No. ohms inches Use each<br />

37-A 2 Primary 11 x8 Phantom toll<br />

windings, 35 circuits and<br />

each . simplex cir-<br />

2 Secondary cuits . . . . . . . $18 .90<br />

windings, 35<br />

each .<br />

39-A First winding, Phantom toll<br />

62 ; second circuits and<br />

winding, 37 ; simplex cirthird<br />

wind- cuits . . . . . . . 13.70<br />

ing, 40 .<br />

These have two coils mounted on one base and are<br />

for use on standard repeating coil racks . Size of base is<br />

103/4 in . by 4 in .<br />

The windings of the Nos . 25-C and 25-G are the<br />

same as those of the Nos . 25-A and F respectively, except<br />

that they are brought out to terminals on both ends of the<br />

base .<br />

. Code No<br />

Resistance<br />

ohms Use<br />

List Price<br />

each<br />

25-A 2 Primary windings,<br />

23 each .<br />

2 Secondarv<br />

windings, 23<br />

each.<br />

Cord circuits and in-<br />

<strong>com</strong>ing trunk circuits<br />

on central<br />

battery switch-<br />

boards . . . . . . . . . . . $7 .65<br />

25-F 2 Primary wind- 48 volt battery long<br />

ings, 23 each . distance and in-<br />

2Secondary <strong>com</strong>ing toll trunks<br />

windings, 23 central battery<br />

each, switchboards . . . . . 8 .30<br />

2 Non - inductive<br />

windings, 40<br />

each .<br />

25-C 2 Primary wind- Cord circuits and inings,<br />

23 each. <strong>com</strong>ing trunk cir-<br />

2Secondary cuits of central<br />

windings, 23 battery switcheach<br />

. boards . . . . . . . . . . . 7 .65<br />

25-G 2 Primary wind- 48 volt battery long<br />

ings, 23 each . distance and in-<br />

2 Secondary <strong>com</strong>ing toll trunks<br />

windings, 23 central battery<br />

each . switchboards . . . . . 8 .30<br />

2 Non - inductive<br />

windings, 40<br />

each .<br />

These have one coil per base, and are for use on<br />

standard repeating coil racks . Size of base is in . by<br />

4 in .<br />

The windings of the Nos . 26-C and 26-F are the<br />

same as those of the Nos . 26-A and 26-E respectively, except<br />

that they are brought out to terminals on both ends<br />

of the base .<br />

Code No .<br />

Resistance<br />

ohms Use<br />

Last Price<br />

each<br />

26-A 2 Primary windings,<br />

23 each .<br />

2Secondary<br />

windings, 23<br />

each .<br />

Cord circuits and in-<br />

<strong>com</strong>ing trunk circuits<br />

of central<br />

battery switch-<br />

boards . . . . . . . . . . . $4 .05<br />